7. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip. The clevis pin must go through the holes in the motor coupling and the holes in the downrod (Figure 5). Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. WARNING ! It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP MOTOR COUPLING HAIRPIN CLIP CLEVIS PIN DOWNROD LEADS TO BE POSITIONED IN SLOT IN MOTOR COUPLING CLEVIS PIN Figure 5 NOTE: Make sure the unused black motor lead is capped with a wire connector. Make sure all wire connectors are completely inside motor coupling cover and not pinched between the motor coupling cover and motor. 9. Screw two 1” threaded studs (supplied) into the motor (Figure 6). Leave approximately 7/8” of the stud extending above the motor. Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two knurled knobs (supplied) to secure the cover. KNURLED KNOB 1" THREADED STUD MOTOR COUPLING COVER WIRE CONNECTORS 7/8"MOTOR Figure 6 8. Install the setscrew (supplied in the loose parts 10. Position the ceiling cover over the downrod. Be bag) in the motor coupling and tighten using the sure the cover is oriented correctly, with the large 5/32” setscrew wrench (supplied) (Figure 5). opening at the top (Figure 7). 5 17. Reinstall the switch housing assembly by passing the wires from the motor shaft through the collar, screw the assembly onto the motor shaft (Figure 11). Tighten the setscrew using the 5/32” hex wrench (supplied). Engage the connector from the switch housing to the motor connector. The two connectors are keyed and must be mated correctly before they can be engaged. 6 11. Reinstall the hanger ball on the downrod as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod (Figure 7). Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble. 12. Use three 10-24 x 3/8" pan head screws and flat washers (supplied) to secure flange to blade (blades ordered separately) (Figure 8). Repeat for the remaining four blades. 13. Using the 5/32” hex wrench (supplied), loosen the setscrew in the collar and unscrew (counterclockwise) the switch housing assembly from the motor shaft (Figure 9). Do NOT remove the flat washer from the motor shaft. SETSCREW DOWNROD PIN HANGER BALL CEILING COVER Figure 7 10-32 X 5/8" OVAL HEAD SCREW (3 PER BLADE ASSEMBLY) MOTOR HUB BLADE FLANGE FLAT WASHER (DO NOT REMOVE) FLAT WASHER (3) BLADE 10-24 x 3/8" PAN HEAD SCREW (3) BLADE FLANGE Figure 8 SWITCH HOUSING ASSEMBLY SETSCREW COLLAR Figure 9 Figure 10 14.Use the 10 round recessed holes in the motor hub marked with "5" and install the five blade assemblies in accordance with Step 15. 15. Loosely attach one blade assembly to the motor hub using two 10-32 x 5/8" oval head screws (supplied) (Figure 10). Make sure the screws are NOT tightened at this time. Repeat this procedure for the four remaining blade assemblies. 16.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws In a clockwise sequence. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again. MOTOR SWITCH HOUSING CONNECTOR CONNECTOR SWITCH HOUSING ASSEMBLY SETSCREW COLLAR Figure 11 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. ! WARNING To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades, or cleaning the fan. ! WARNING WARNING ! The fan must be hung with at least 7' of clearance from floor to blades (Figure 12). CEILING AT LEAST 7' FLOOR Figure 12 WARNING ! The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs. 18. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 13). WARNING ! To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan s...
Este manual também é adequado para os modelos :Fans - CF2500OB01 (317.97 kb)
Fans - CF2500S01 (317.97 kb)
Fans - CF2500TG01 (317.97 kb)