Fabricante : Delta Electronics
Arquivo Tamanho: 194.09 kb
Arquivo Nome :
|
Facilidade de uso
N LOAD L SUPPLY L LOAD N SUPPLY DP 13A, 250V BLUE (NEUTRAL) BROWN (LIVE) FUSE ON Technic Detail. Dimensions (825 D). Height x Width x Depht (in cm. 84-117 x 59,9 x 51.. Dimensions (8259 D). Height x Width x Depht (in cm. 84-117 x 89,9 x 51.. Weight (825 D). Net. 10,7 k. Gross. 16,2 k. Weight (8259 D). Net. 13,1 k. Gross. 19,6 k. Maximum absorbed power. 250. Motor absorption. 1 x 170 . Lighting. 2 x 40 . Length of the cable. 100 c. Fan powers (speed), speed in compliance with DIN 4497. Extractor version. . 179 m3/. . 219 m3/. . 336 m3/. . 402 m3/. Filter version. . 102 m3/. . 150 m3/. . 252 m3/. . 265 m3/. Flange: 120 mm . Installatio. Safety warnings for kitchen unit installe. l When used as an extractor unit, the hood must be fitte. with a 120mm diameter hose. l If the fumes must be forced out through the wall, yo. must obtain a MKZ sizable wall exhaust pipe (wit. external exhaust and air intake), E-Nr.- 610 899 004 (O 12. mm) which is one of our optional parts. l When installing the hood, make sure you respec. the following minimum distance from the top edg. of the cooking hob/ring surfaces. electric cooker. 600 m. gas cooker. 650 m. coal and oil cooker. 700 mm min. l The air outlet must not be connected to chimney flues o. combustion gas ducts. The air outlet must under no cir. cumstances be connected to ventilation ducts for rooms i. which fuel-burning appliances are installed. l It is advisable to apply for authorization from the relevan. controlling authority when connecting the outlet to a. unused chimney flue or combustion gas duct. The air outlet installation must comply with th. regulations laid down by the relevant authorities. l When the unit is used in its extractor version, . sufficiently large ventilation hole must be provided, wit. dimensions that are approximately the same as the outle. hole. l National and regional building regulations impose . number of restrictions on using hoods and fuel-burnin. appliances connected to a chimney, such as coal or oi. room-heaters and gas fires, in the same room. l The national decree on fuel-burning systems specifies . maximum depression of 0.04 bar in such rooms. l Hoods can only be used safely with appliances connecte. to a chimney if the room and/or flat (air/environmen. combination) is ventilated from outside using a suitabl. ventilation hole approximately 500-600 cm2 large t. avoid the possibility of a depression being created durin. operation of the hood. If you have any doubts, contact the relevant controllin. authority or building inspector.s office. l Since the rule for rooms with fuel burning appliances i. .outlet hole of the same size as the ventilation hole., . hole of 500-600 cm2, which is to say a larger hole, coul. reduce the performance of the extractor hood. l If the hood is used in its filtering function, it will operat. simply and safely in the above conditions without th. need for any of the...
Este manual também é adequado para os modelos :Fans - DUNSTABZUGSHAUBE 825 D (194.09 kb)
Fans - DUNSTABZUGSHAUBE 825 D (194.09 kb)
Fans - DUNSTABZUGSHAUBE 825 D (194.09 kb)
Fans - DUNSTABZUGSHAUBE 8259 S (194.09 kb)