|
Facilidade de uso
Wall Mounting Remove the wall mounting bracket from the back of the heater and using it as a guide (see Fig. 2) mark off the hole positions on a suitable wall (a minimum height of 2 meters is required from the floor level to the bottom of the bracket). Solid brick or concrete block walls must be drilled and plugged. Fix the wall mounting bracket to the wall and assemble the heater to the extension tube using a bolt and wing nut fitted into hole 1 shown in Fig. 3a. Rotate the heater as shown in Fig. 3b, and fix the heater into position using the remaining bolt and wing nut in hole 2. Pivot and rotate the heater into the desired position and tighten all three wing nuts. A 6mm Allen key can be used as an aid to tightening the bolts. Electrical and Control connections Note: The installation of this appliance should be carried out by a competent electrician and be in accordance with the current IEE wiring regulations. Electrical power and control connections for all CFS models are made by removing the control housing and bottom Panel. The control housing (‘y’ in Fig. 4 and Fig. 5) is detached by removing the two screws and hinging the housing as shown (see step 1 in Fig. 5). The bottom panel (‘x’ in Fig. 5) is detached by removing two screws and lifting off as shown (see steps 2 & 3 in Fig. 5). Note : Removal of bottom panel is not required for CFS30. Note: A suitable local isolating switch must be provided in the electrical supply circuit as close as possible to the heater with at least 3mm clearance on each pole. CFS30 General A range of robust, durable wall mounting fan heaters designed to coordinate with the Dimplex range of Air Curtains, providing environmental heating in commercial and light industrial environments. The heaters work by gradually raising the air temperature in the building and should be positioned so as best to achieve an even temperature distribution. The product range has outputs of 3kW, 6kW, 9kW and 12kW. Model Heat Output kW Electrical Supply Electrical Load (per phase) A Weight k g Min Installed height m CFS30 1.5 / 3 230-240V~ 1PN 12.7 7.6 2 CFS60 3 / 6 220-240V~ 1PN 26.0 13.5 2220-240V~ 3P 15.6 380-415V~ 3PN 9.0 CFS90 6 / 9 220-240V~ 1PN 38.8 14.5 2220-240V~ 3P 23.0 380-415V~ 3PN 13.3 CFS120 6 / 12 220-240V~ 1PN 51.6 14.5 2220-240V~ 3P 30.4 380-415V~ 3PN 17.5 Remove knock-out from back panel of heater and feed appropriate supply cable (see ‘a’ in Fig. 4) to terminal block ‘c’ (see Fig. 4). Make electrical connections as shown in Fig. 7 and fix cable in back panel using suitable cable gland (not supplied). By removing the other knock-out and using 5 core cable (see ‘b’ in Fig. 4) make the control connections to terminal block ‘d’ also shown in Fig. 4. CFS60, CFS90 & CFS120 Remove large knock-out from back panel of heater and feed appropriate supply cable (see ‘a’ in Fig. 6) to terminal blocks ‘c’. Make electrical connections as shown in Fig. 9 and fix cable in back panel using suitable cable gland (not supplied). By removin...
Este manual também é adequado para os modelos :Fans - CFS30 (1.9 mb)
Fans - CFS60 (1.9 mb)
Fans - CFS90 (1.9 mb)