|
Facilidade de uso
Chose upper/lower heat and maximu. 100° C and dry the filter for 10 minutes. Read als. the filter instructions. The filter should be changed after about 3 years a. its ability to absorb smells has reduced by then. The filter insert is removed from the frame and i. replaced with a new one (according to the filte. instructions). AB 21 Fig. 3 If the cooker hood does not function Before calling for service Check the plug is correctly connected to the wal. socket. Check the fuse. Do not attempt any repair. yourself that are likely to lead to further damage. If th. problem remains, contact your dealer or an approve. service company. Remember to save your purchas. receipt and warranty card (only used in som. countries). Service and spare parts Your dealer or service company will supply yo. with service and spare parts. Be sure you have th. product number and model name at hand whe. ordering service or parts. Changing the cord If the cord to the cooker hood is damaged it mus. be replaced by an approved service company. Thi. is because special tools are required for the job. Technical data Model QC 520 QC 620 QC 720 Airflo. Max. 320 m ./h x) 180 m ./. 320 m ./h x) 180 m ./. 320 m ./h x) 180 m ./. Min. 160 m ./. 160 m ./. 160 m ./. Siz. Heigh. 45 m. 45 m. 45 m. Widt. 498 m. 598 m. 698 m. Dept. 445 m. 445 m. 445 m. Ligh. Max 11 W P. Max 11 W P. Max 11 W P. Grease filte. 1 pc. 1 pc. 1 pc. Voltag. 230 . 230 . 230 . Total powe. 111 . 111 . 111 . x) Valid when the cooker hood is fitted with carbon filter. Fig. 4498/598/69846545 Installation Unpacking Check that the cooker hood is not damaged. Transportation damages should immediately b. reported to the transport company. Damages, fault. and eventually missing parts should immediately b. reported to the retailer. Dispose carefully of th. packaging material so that it is out of the way of smal. children. Remove the transport supports (C-Fig. 9). Position The cooker hood should be mounted freely hanging o. the wall. The cooker hood must be at least 40 c. above electric burners or electric range (Fig. 5). Th. cooker hood is not approved for mounting above ga. burners or gas range. Min40cm Fig. 5 Electrical connection The electric outlet should be placed above the cooke. hood or inside a wall cupboard. The hood has a powe. cord and moulded plug with earth connection for . wall outlet of 230V. Mounting of cooker hood in a cupboard, Alt. 1 (Fig. 6): . Cut an opening and drill 4 holes in the underside o. the cupboard. Use the template printed on th. packaging. . Mount the locknuts (A) on the cooker hood. .Mount the cooker hood with four screws (B) an. washers (C). 2ABCFig. 6 Mounting of cooker hood in a cupboard, Alt. 2 (Fig. 7): . Cut an opening in the underside of the cupboard. Use the template printed on the packaging. . Mount the cooker hood with two screws (A) and th. spacers (B). . Fit the plastic covers (C). Fig. . ABC Mounting of cooker hood between cupboards (Fig. 8): . Fit the two brackets (A) on the cooker hood. . Mark out the exact location to drill in the sides o. the cupboards. . Mount the cooker hood with four screws (B). washers (C) and the nuts (D). ABCDFig. 8 Mounting of cooker hood on wall (Fig. 9): . Mark out where the 4 holes shall be drilled on th. wall. Drill in the markings with an O8 mm drill an. fit rawl plugs into the holes. Use the templat. printed on the packaging. . Fix the screws (A). Leave about 5 mm distanc. between the screws and the wall. . Hook the cooker hood on the screws (A). . Remove the grease filter and mount the screws (B. in the two lower holes. Remove the grease filter b. pulling it backwards (against the wall) and the. downwards. . Tighten the screws (A). . Mount the grease filter. BAFig. 9 Mounting the cold air valve (Fig. 10): Not applicable for recirculation. The cold air valv. consists of a damper seat with two valves, which shal. be fitted into the hood outlet. If there is no other for. of ventilation to expel air from the kitchen than th. hood, the outer end of the valves should be clipped of. and removed. Insert a pen or something simila. between the valves. These should open up easily now. Mounting the venting kit (Fig. 11): Not applicable for recirculation. A complete ventin. kit is available as an optional extra. The ventilatio. pipe (A) is pulled over the hood.s evacuation flang. (B) and is held firmly in place with a clamp. Make sur. the pipe is as straight as possible and does not hinde. the movement of the valve flaps. The pipe is connecte. to the mouth of the duct with the metal flange (C. which is included in the kit. Fitting the carbon filter Only applicable for recirculation. The LONG LIF. carbon filter (special accessory) for this hood is fitte. instead of the grease filter. The LONG LIFE carbo. filter is both a grease and carbon filter for reduction o. cooking smells. An opening must be made at the top or front of th. cupboard (min. 100 cm.) where the hood is fitted, s. the cleaned air can freely circulate back int...
Este manual também é adequado para os modelos :Fans - BREEZE QC 520 (316.72 kb)
Fans - BREEZE QC 620 (316.72 kb)