|
Facilidade de uso
Important: the handles of both grease filters must be visible after assembly. Press the F key to set the elapsed hours counter to zero. Flashing of the indicating lamp goes off. Fig. 15 Fig. 15 Cleaning the extractor hood Clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either. Clean the stainless-steel extractor hood (AW 200) with stainless steel cleaner. Do not place any objects with sharp-edged or rough bottoms (e.g. ceramic cups) on the hood. Circulating air mode The activated charcoal filter eliminates kitchen smells in the circulating air mode. In normal use (1 to 2 hours daily), the activated charcoal filter must be replaced approximately once a year. If no activated charcoal filter is installed, kitchen smells will not be eliminated. Replacing the activated charcoal filter: remove the stainless steel grease filters. Push in the clips on the side of the activated charcoal filter and remove the activated charcoal filter downwardly. Activated charcoal filters (KF 001-010) are available through your specialist dealer. Only use original filters. Activated charcoal filters do not contain any dangerous substances. They can be disposed of through the household refuse collection. 5. Maintenance Fig. 16 The appliance must be disconnected from the power supply during all repair work. If the appliance does not function correctly, check the fuses first. If the power supply is functioning correctly, but your appliance still does not work, please contact your Gaggenau dealer who will provide you with the address and telephone number of your nearest manufacturer’s authorized service agent or contact Gaggenau USA on (800) 828-9165. Specify the appliance type (see rating plate). Repairs may only be carried out by authorised technicians, in order to guarantee the safety of the appliance. Unauthorised tampering with the appliance will invalidate any warranty claims. Only ever use original spare parts. Lamp replacement Caution: disconnect the power supply before replacing lamps (switch off the fuse)! Caution: lamps may still be hot shortly after use! Risk of burns. – Detach the ring from the lamp cover. Note: make sure that the glass will not fall out (Fig. 16). – Pull out the lamp (Fig. 17). Defective lamps must only be replaced by lamps of the same type! (12 V/20 W/G4 lampholder) Inserting the lamp – Insert the lamp in the lampholder. Note: do not touch the halogen lamps with your hands. Use a cloth and touch the lamp only on its edges. – Engage the lamp cover. – Connect the appliance to the mains again. Fig. 17 6. Assembly instructions WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b.) Sufficient air is needed for proper combustion end exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning (ASHRAE), and the local code authorities. c.) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d.) Ducted fans must always be vented to the outdoors. e.) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. f.) NEVER place a switch where it can be reached from a tub or shower. WARNING: To reduce the risk of fire, use only metal ductwork. 6.1 Technical data Max. weight depending on version: 28.5 kg Dimensions: 353/8 . . x 22 . . Electrical connection Pay attention to the rating plate data. The appliance must only be connected by an authorised specialist. The specialist is responsible for perfect functioning of the appliance at its installation location. He must explain the operating principle of the appliance to the user with reference to the operating instructions. He must explain to the user how the appliance can be isolated from the mains whenever required. Connection possibilities The plug of the connecting cable is inserted into the socket that is located behind the duct cover on the wall. If this is not possible, the disconnection of all the poles of the appliance from the mains must be achieved by way of the domestic fuse, or by using an accessible disconnecting device with a contact gap of at least 3.0 mm. 6.2 Installation The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. This hood has been approved for installatio...
Este manual também é adequado para os modelos :Fans - AW 200-790 (881.56 kb)