|
Facilidade de uso
skirting size is 1 5 x 120mm. Note that the smallest wall spacing should be used only when the skirting board is of the modern slim type, or there is no skirting board at all. MUST STAND VERTICAL You must fit a retaining screw at each end of the heater. 100mm {4") Skirling Goarrf —Lf'"' Outer Siol 1 SOmm i6“> Skirting Beard It THE HEATER A clear space of at least 3" (75mm) must be left at either side of the heater, and any projections or shelves must be at least 10" (250mm) above the heater casing. Curtains must not be draped around or in contact with the casing. A shelf unit is separately available for fitting above heaters. (i............. itj n 1 k The top panel and front panel are joined and should be removed as one assembly. To do this, remove the screws fixing the rear flange of the top panel, and remove the screws along the bottom edge of the front panel. Carefully swing out bottom of front panel and lift assembly clear of casing, this operation also removes the control knobs under the flap. Put assembly in a safe place to avoid damage to paint etc. NOTE: Removal of the lower front panel is only possible after the top and main front panel assembly has been removed. First, remove the two black screws situated on the lower front face, then remove the four side screws. The lower front panel will then pull forward, clear of the heater. ENSURE THAT THE CABLES ARE NOT TRAPPED UNDER THE HEATER LEGS Storage Heater Circuit ‘ACW’ ^-""MODELS ONLY LIMIT ST AT ROOM AND CUT OUT STAT Storage Elements 79368S _ 75772003S 79358S 1^757720023 fgmT nn nn nn 75772001 S+\ ft.. XX..Jpt.-XJL m mt wm—J Ldum “ — Iuum m w 7> (7) MAINS TERMINALS IMPORTANT: For earthing, loosen the earth screws sufficiently to wrap the mains' earth wire around it between flat washer and cup washer, and retighten the earthing screw. Both restricted and unrestricted supply wires must be connected to their respective earthing points. Feed the mains cable through the appropriate cable clamp and make connections as marked on the heater. Pull back any slack through the clamp and tighten clamping screw. If mains connection is to be made from the left hand side, at this point the mains lead must be secured to the base of the fan box by fixing the ties provided in the fixing kit through the holes along the rear of the fan box base. CONNECTING THE SUPPLIES RESTRICTED SUPPLY Combi Fan Heater Circuit TEHMHML BLOCK ■OUTPUT THERMOSTAT L © Charge Rated Period Charge 79348S& 75772001S 7 hours 12 kWh 79358S& 757720025 7 hours 18 kWh 79368S & 75772003S 7 hours 24 kWh NOTE: The fan heater element is factory set at full rating. If ° load rating only is required the installer should move the black wire as indicated in the circuit diagram. ELEMENT ASSEMBLY (WITH SAFETY CUT OUT) WARNING Remove the inner front panel; this carries on it's inner face the front insulation slab. Handle this with care, the insulation must not be damaged. REMOVE ALL THE PA...
Este manual também é adequado para os modelos :Fans - 75772001S (635.77 kb)
Fans - 75772002S (635.77 kb)
Fans - 75772003S (635.77 kb)
Fans - 793585 (635.77 kb)