Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Best, Modelo 222D

Fabricante : Best
Arquivo Tamanho: 173.26 kb
Arquivo Nome : 4983900en.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


1). Close off the unused hole using the bayonet fitting caps D. • Important! To use the back hole B, remove switch F from the top hole. — Fig 2. 4 • Move the lever L to position A — Fig. 3. • When connecting up the hood using a telescopic wall pipe, you should use an uninflammable outlet hose ABS 120 (120 mm 0) available as an accessory. Recirculation mode • The air is filtered and recirculated through the front grid. • Move the lever L to position F — Fig. 3. You will need an original KFF activated carbon filter for filtering function. (Available as an accessory). Summer/Winter Hood Conversion • To avoid excessive heat loss during the winter months, we recommend that the hood be converted from extraction mode to recirculation mode. • In order to convert the hood, a charcoal filter (available as an accessory) is required. Follow the instructions for operating the hood to recirculate air. • When the temperature outdoors becomes more mild (spring), the filter can be removed and the hood converted once again for to extraction. Please consult the assembly instructions for operating the hood in extraction mode. 5 Electrical connection 220-240 V - using fixed power supply line with plug. (The unit should only be connected up by an authorized electrician). Your appliance must be connected to fixed wiring via the use of a double pole swiched fused spur outlet with or without pilot lamp. We strongly recommend the appliance is connected by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations. NOTE: the terminology “DOUBLE POLE” means that both the live and neutral supplies are swiched and disconnected at the same time. The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance. IMPORTANT The wires of the mains lead supplied with this appliance are coloured in accordance with the following code: Blue-Neutral Brown-Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The whire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. - - -BLUE BROWN 6 Technical details Dimensions Height x Width x Depth (in cm) 13 x 59,9 x 51 Weight Net: 6,9 kg Gross: 7,8 kg Maximum absorbed power: 205 W Motor absorption 1 x 125 W Lighting: 2 x 40 W Length of the cable: 110 cm Fan powers (speed), speed in compliance with DIN 44971 Extraction mode Speed 1 115 m3/h Speed 2 145 m3/h Speed 3 180 m3/h Intensive speed 210 m3/h Recirculation mode Speed 1 110 m3/h Speed 2 117 m3/h Speed 3 125 m3/h Intensive speed 145 m3/h Flange:120 mm 0 7 Installation Safety warnings for kitchen unit installer • When used a...

Este manual também é adequado para os modelos :
Fans - 222D (173.26 kb)
Fans - 222D (173.26 kb)
Fans - 222D (173.26 kb)
Fans - 222D (173.26 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias