Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Broan, Modelo PLHV36W7CC

Fabricante : Broan
Arquivo Tamanho: 1.15 mb
Arquivo Nome : PLHV36W7CC_use-care.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d) Ducted fans must always be vented to the outdoors. WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. A WARNING Electrical Shock Hazard - Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amounts of mercury which must be recycled or disposed of according to Local, State, and Federal Codes. 3 Installation pOR residential use only not to be installed over gas grills please read entire instructions before proceeding, installation must comply with all local codes. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Safety Warning: Turn off power circuit at the service entrance and lock out panel, before wiring this appliance. Requirement: 120 V AC, 60 Hz. IS or 20 A Dimensions Dimensions A (Range of adjustable ht.) * 29 15/16-48 V2 B (Min. ht. with one cover)* 22 3/R C (ht. from glass to bottom)* 3 W (widht)* 3S 7/8 D (depth)* 19 5/8 DD (depth of the cover)* 11 5/8 WW (widht of the cover)* Weight: 44 pounds Diameter of Transition 6” 11 5/16 Diameter of exhaust Duct required 6” Figure I* Note: All dimensions are shown in inches. * Dimensions are given from base of hood to ceiling, and include clearance required for installation. Considerations before installing Hood 1. Grease filters are not mounted and are located inside the package with the hood. Be sure to get them before disposing of your package. 2. For the most efficient air flow exhaust, use a straight run or as few elbows as possible. CAUTION: Vent unit to outside of building, only. 3. If allowed in your area, use metallic flex ducting only to connect rigid duct directly to transitions. 4. COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house. 5. Hood installation height above cooktop is the users preference. The lower the hood above the cooktop, the more efficient the capturing of cooking odors, grease and smoke. We recommend the hood be installed 30-36" above the countertop. The lower height may be inconvenient for tall people and large cooking vessels. Check your ceiling height and the hood height maximum before you select your hood. 4 Installation Prepa...

Este manual também é adequado para os modelos :
Fans - PLHV36W7CC (1.15 mb)
Fans - PLHV36W7CC (1.15 mb)
Fans - PLHV36W7CC (1.15 mb)
Fans - PLHV36W7CC (1.15 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias