Log:
Assessments - , GPA: ( )

Instruções de Operação Bryant, Modelo FAN UNIT FH4B

Fabricante : Bryant
Arquivo Tamanho: 241.24 kb
Arquivo Nome : pdsfh4b.01.3.pdf

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


The units are the right choice if you need versatility and affordability in a fan unit. These fan coil units offer an air handler for practical, no-nonsense application and outstanding performance. The multipoise units allow greater flexibility to meet your upflow, downflow, or horizontal installation requirements, and offer multiple electric entry to permit quick, hassle-free hookup (003 and 004 when coupled with coil are upflow/downflow only). All models come fully equipped with solid-state cooling controls. The FH4B, with its 3-speed motor and field-installed heater package, provides the application versatility required for most installations. Heater packages are available from 3- through 30kw, either fused or with a circuit breaker, or non-fused for 10-kw and less. FEATURES • Prepainted galvanized sheet metal • Cooling controls with every unit • 3-speed motor • Unique cabinet design to meet air leakages regulations • Factory-supplied cleanable filter • Easy access filter for cleaning—no tools required • Air sealed filter door • Field-installed heater packages 3- through 30-kw, fused, circuit breaker, non-fused (10-kw and down) • Factory-supplied power plug • Control board with replaceable 5-amp blade type auto fuse • Foil-faced high-density super thick R-4.2 insulation • Multiple electric entry • HUD approved for manufactured housing • 40-va, 208/230-v transformer • All models listed with UL (U.S. and Canada) and ARI MODEL NUMBER NOMENCLATURE F H 4 B N F 001015AEAA A—Common Unit E—Minor Engineering Change A—Standard Unit A—Standard Unit Electric Heater (kw) 003 015 005 020 008 024 009 030 010 001— 800 CFM 002—1200 CFM 003—1600 CFM 004—2000 CFM F— Single Piece Cabinet with 1 in. Super Thick Insulation N—208/230-1-60 B—Series 4—Multipoise H—Fan Unit F—Fan Coil MANUFACTURERCERTIFIED TOARIASCOMPLYING WITH ARISTANDARD210 UNITARY AIRCONDITION NG EQU PMENT MANUFACTURERCERTIFIED TOARIASCOMPLYING WITH ARISTANDARD240 UNITARY HEATPUMP EQUIPMENT ® REGISTERED QUALITY SYSTEM CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. —2— —3— DIMENSIONS UNIT SERIES A B C F ACCY. COIL CONFIGURATION OPERATING In. In. In. In. SLOPE “A” WEIGHT (Lb) FH4BNF001 E 42-11/16 14-5/16 12-7/16 12-5/16 175 FH4BNF002 E 49-5/8 17-5/8 15-3/4 15-5/8 192 FH4BNF003 E 49-5/8 21-1/8 19-1/4 19-1/8 106 FH4BNF004 E 53-7/16 21-1/8 19-1/4 19-1/8 114.5 A02300 —4— DIMENSIONS Continued A02301 DIMENSIONS Continued POWER ENTRY FIELD SUPPLIED OPTIONS SUPPLY DUCT LOW VOLT ENTRY OPTIONS 24-IN. FRONT SERVICE CLEARANCE UNIT FH4B001 FH4B002 A 12 In. 17 In. A 1 . . 2 . . 19. FIELD MODIFIED SIDE RETURN LOCATION FOR SLOPE COIL UNITS ONLY FIELD SUPPLIED RETURN PLENUM A02294 *Side Return not compatible when used in conjunction with accessory cooling coil Field-modified Side Return Location For Slope Coils Only —5— SPECIFICATIONS UNIT SIZE 001 002 003 004 FAN Air Discharge CFM (Nominal) Motor Hp (PSC) 850 1/4 1300 1/3 1700 3/4 2000 3/4 FILTER 21-1/2 x 13 21-1/2 x 16-3/8 21-1/2 x 19-7/8 AIRFLOW PERFORMANCE* (CFM) SIZE BLOWER SPEED EXTERNAL STATIC PRESSURE (IN. WC) 0.10 0.20 0.30 0.40 0.50 0.60 208 230 208 230 208 230 208 230 208 230 208 230 FH4B001 HIGH 1173 1270 1135 1225 1090 1170 1045 1126 993 1058 925 981 MED 900 1025 875 991 847 963 810 922 768 869 695 802 LOW 579 687 560 663 537 639 505 610 451 554 384 467 FH4B002 HIGH 1630 1841 1605 1798 1567 1748 1525 1696 1480 1629 1415 1560 MED 1244 1438 1225 1407 1190 1383 1170 1342 1141 1308 1100 1265 LOW 1001 1172 985 1147 955 1116 930 1094 908 1062 850 1024 FH4B003 HIGH — — — — 2118 — 2060 2202 1949 2106 1853 1989 MED 1757 2061 1745 2016 1734 1985 1716 1943 1686 1890 1624 1802 LOW 1290 1535 1286 1535 1281 1528 1277 1515 1263 1467 1245 1431 FH4B004 HIGH — — — — 2257 — 2235 — 2188 — 2113 2336 MED — — 1930 2215 1914 2196 1887 2163 1838 2106 1787 2047 LOW 1620 1881 1620 1870 1613 1864 1607 1853 1594 1836 1562 1802 * With factory approved filter, 10-kw elec heat 001 and 002 sizes, 15-kw elec heat 003 and 004 sizes 230-volt. AIRFLOW PERFORMANCE WITH ACCESSORY COIL (CFM) MODEL AND SIZE BLOWER MOTOR SPEED TOTAL EXTERNAL STATIC PRESSURE (IN. WC) 0.10 0.20 0.30 0.40 0.50 0.60 208 230 208 230 208 230 208 230 208 230 208 230 FH4B001 WITH KFAEC0501024 HIGH 945 975 900 930 840 870 780 805 695 725 560 595 MED 835 900 795 855 745 800 690 740 610 650 470 510 LOW 605 695 575 665 530 625 485 580 425 510 340 395 FH4B002 WITH KFAEC0601036 HIGH 1485 1550 1425 1490 1365 1420 1300 1350 1230 1275 1150 1190 MED 1235 1380 1200 1325 1160 1265 1110 1210 1055 1140 985 1070 LOW 1035 1185 1010 1150 980 1115 940 1070 890 1010 825 935 FH4B003 WITH KFAEC0301048 HIGH 1880 1935 1785 1830 1700 1735 1615 1645 1520 1555 1430 1460 MED 1740 1840 1660 1750 1585 1660 1510 1575 1435 1485 1350 1390 LOW 1425 1605 1395 1555 1360 1495 1315 1430 1255 1360 1170 1270 FH4B004 WITH KFAEC0401060 HIGH 2145 2245 2085 2185 2030 2115 1965 2045 1905 1975 1830 1895 MED 2025 2175 1970 2110 1915 2050 1860 1990 1805 1905 1740 1830 LOW 1680 1895 1655 1855 1625 18...

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias