Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Bryant, Modelo FAN COIL UNITS FF1DNA

Fabricante : Bryant
Arquivo Tamanho: 86.38 kb
Arquivo Nome : pdsff1d.18.2.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


They are available with factory- or field-installed electric heaters both of which include the disconnect. A field- installed cooling control with disconnect is also available. A TDR (Time Delay Relay) is included with either the electric heat or the cooling control packages. The FF1DNE models are available with a factory installed TXV. This fan coil may be installed free standing, wall hung or flush mounted in the wall. The 22-in. wide cabinet size in all models allows units to fit between standard stud spacings. No return air ductwork is required if the application provides for return air in the front of the cabinet through either a louvered closet door or an optional accessory decorative grille panel. The cabinet exterior is made of pre-painted galvanized sheet metal. The cabinet is fully insulated to meet applications in conditioned space. Additional insulation is required if the unit is installed in an unconditioned space. Unit is supplied with replaceable filter. Multispeed direct-drive PSC blower motors have been selected to provide the proper air handling for both heating and cooling. Motors are suspended at 3 points on rubber grommets for quieter operation. All refrigerant lines, electrical power, and thermostat wiring enter from the top of the cabinet. Sweat-type refrigerant connections on both liquid and suction lines make for swift, low-cost installation. All service access to the unit is conveniently located in the front. The CHECK-FLO-RATER® piston ensures efficient and dependable refrigerant metering, and eliminates potential service requirements of other metering devices. The CHECK-FLORATER ® is located inside the unit, easily accessible for piston maintenance or changeout. In addition, units can be factory ordered with a hard shut-off thermostatic expansion valve (TXV) metering device for performance improvement. The drain pan is constructed of high-impact, sound-deadening, corrosion-proof polyester resin. Primary and secondary drain connections exit from the bottom or either side of the cabinet. MODEL NUMBER NOMENCLATURE F F 1 D N A018075 Electric Heater (kw) 000 005 075 011 Nominal Capacity (Btu) 018—18,000 024—24,000 030—30,000 A—Standard E—TXV N—208/230-1-60 D—Major Series 1—Upflow F—Through-the-Wall F—Fan Coil MANUFACTURERCERTIFIED TOARIASCOMPLYING WITH ARISTANDARD240 UNITARY HEATPUMP EQU PMENT ® MANUFACTURERCERTIFIED TOARIASCOMPLYING WITH ARISTANDARD210 UNITARY AIRCONDITIONNG EQUPMENT • CERTIFICATION • LISTING • TESTING • INSPECTION ® CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. PHYSICAL DATA MODEL FF1DNA/FF1DNE 018 024 030 Fan Rpm (2-Speed) Motor HP (PSC) Wheel (In.) 810/750 1/12 10 x 6 980/780 1/5 10 x 6 1110/950 1/3 10 x 6 Filter (Permanent) (In.) 16 x 20 16 x 20 16 x 20 Connections (Sweat) Suction OD Liquid OD Condensate (FPT) (In.) (In.) (In.) 5/8 3/8 3/4 3/4 3/8 3/4 3/4 3/8 3/4 Operating Weight (With Electric Heat) (Lb) 76 79 82 NOTE: Rough-in dimensions are 38-1/4 x 22-1/4 inches. CLEARANCES A minimum clearance of 21 in. is required in front of the access panels for servicing. Please note that this clearance is recommended for servicing only. Installation clearances from combustible materials are: 0 in. from cabinet and supply-air duct (plenum included). Leave adequate room for the condensate pan and refrigerant line connection. NOTE: 22-3/4 to 24-in. on-center between-studs and 38-1/8 to 36-3/4-in. top-to-bottom inside-studs spacing. —2— DIMENSIONS — FF1DNA, FF1DNE OUTLET AIR INLET AIR SUCTION TUBE COIL 8. DIA. SIDE VIEW FRONT VIEW TOP VIEW BOTTOM VIEW PRIMARY DRAIN PATCH PLATE FAN COIL BASE 22 1.8. 11 3.16. 3 1.4. 24 1.16. 5 11.16. 5. 10 1.16. 1 5.8. 5 3.16. 1 92 13.16.2 7.16.2 3.8. 7.8. 15 3.16. 8 1.4. 4 3.16. 11 1.16. 9 7.16. 11 1.16. 5. 38 1.16. REFRIGERANT LINES ENTRY NOTE: 1. SERIES DESIGNATION IS THE 14TH POSITION OF UNIT MODEL NUMBER. .4. 2 33.4. 1 1. KNOCKOUT 3.4. LOW VOLTAGE ENTRY ( 7.8. DIA. HOLE) POWER ENTRY 1 3.8. DIA. KNOCKOUT 7.8. DIA. HOLE .16. BLOWER, CONTROL AND ELECTRIC HEATER ACCESS PANEL LIQUID TUBE UNIT CONNECTION SIZES SUCTION, 018, 024, 030 -3.4. I.D. SWEAT LIQUID, 3.8. I.D. SWEAT CONDENSATE, 3.4. NPT FILTER MEDIA SECONDARY DRAIN 13.16. A98336 —3— SPECIFICATIONS UNITS WITHOUT ELECTRIC HEATERS OR CONTROLS UNIT SIZE 0180 0240 0300 RATINGS & PERFORMANCES Nominal Capacity (Btuh)* 18,000 24,000 30,000 Nominal Airflow (CFM) 650 870 1080 ELECTRICAL Unit Volts-Phase (60 Hz) 208/230—1 208/230—1 208/230—1 Operating Voltage Range 187—253 187—253 187—253 Internal Circuit Protection None Minimum Ampacity for Wire Sizing — Minimum Wire Size† 14 Maximum Fuse Size (Amps or Ckt Bkr) 15 Control Transformer 24V (Va) — INDOOR COIL Rows & Fins Per In. 2 & 14 3 & 14 Height x Width (In.) 18 x 17.8 22 x 17.8 Face Area (Sq Ft) 2.23 2.72 R-22 Refrigerant Metering Device–FF1DNA Check-Flo-Rater R-22 Refrigerant Metering Device–FF1DNE TXV Piston Number‡ 55 63 70 Condensate Drain Connection (Pri-Sec) 3/4 FPT INDOOR BLOWER & MOTOR Wheel Diameter x Width (In...

Este manual também é adequado para os modelos :
Fans - FAN COIL UNITS FF1DNE (86.38 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias