Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Acme Kitchenettes, Modelo Koolmaster PP-32

Fabricante : Acme Kitchenettes
Arquivo Tamanho: 603.2 kb
Arquivo Nome : PP-32_MANUAL_EN.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The information contained in it is however subject to change without notice due to further developments. TABLE OF CONTENTS TABLE OF CONTENTS Page 1. PRECAUTIONS............................................................ 6 2. FEATURES ................................................................. 7 3. LOCATION OF THE CONTROLS .................................... 9 4. MOUNTING INSTRUCTIONS....................................... 11 4.1 CONNECTION .................................................................. 11 4.2 SETTING THE DIP SWITCHES ............................................. 14 5. CONTROLLER SETUP ................................................ 15 5.1 CURRENT CONDITIONS ..................................................... 15 5.2 CONTROLLER PROGRAMS ................................................ 16 5.2.1 Selecting a Program ........................................................ 16 5.2.2 Selecting a Season.......................................................... 16 5.3 ADJUSTING THE ROOM SET POINT .................................... 18 5.4 MINIMUM VENTILATION ................................................... 19 5.4.1 Adjusting Minimum Ventilation's On-Time.......................... 19 5.4.2 Adjusting Minimum Ventilation's Cycle Time ...................... 20 5.5 INLET / VENT DOOR SETTINGS........................................... 21 5.5.1 Inlet Settings (Potentiometer Feedback from Inlets)............... 21 5.5.1.1 Setting DWR-F-1A's ID numbers......................................... 21 5.5.1.2 Adjusting the Air Inlet Compensation .................................. 22 5.5.2 Vent Door Settings ......................................................... 23 5.5.2.1 Adjusting Static Pressure Set Points................................... 26 5.5.2.2 Adjusting Vent Doors Open / Close / Off Times ................... 26 5.5.2.3 Adjusting Stage Level for the Closing of Vent Doors............. 28 5.5.2.4 2nd Group of Pressure Set Points: at Stage X...................... 28 5.5.2.5 2nd Group of Pressure Set Points: at Outside T° X............... 29 5.6 TUNNEL CURTAIN ............................................................ 31 5.6.1 Adjusting Minimum Age for Tunnel Ventilation .................. 34 5.6.2 Selecting the First Tunnel Stage........................................ 34 5.6.3 Adjusting Curtain's Operating Times.................................. 35 5.6.4 Adjusting Static Pressure Hi and Lo Set Points .................... 36 5.6.5 Adjusting Curtain's Timer Cycle ....................................... 36 5.7 FAN STAGES SETTINGS.................................................... 38 5.7.1 Adjusting Fan Stages' Start/Stop Temperatures................... 39 5.7.2 Adjusting Fans Stages' Timer ........................................... 39 5.8 HEATER SETTINGS ........................................................... 41 KOOLMASTER PP-32 REV.01 PP-32 PP-32 5.9 AUXILIARY OUTPUTS....................................................... 42 5.10 ANIMAL AGE ................................................................ 44 5.11 CLOCK OUTPUTS ........................................................... 45 5.11.1 Adjusting Clock Output Start and Stop Times ................... 46 5.11.2 Adjusting Starting Day of Clock Programs ........................ 47 5.12 HISTORY ...................................................................... 48 5.12.1 Resetting Histories ........................................................ 48 5.12.2 Average Temperature History ......................................... 48 5.12.3 Individual Temperature Sensors History ........................... 49 5.12.4 Outside Temperature Sensor History................................ 49 5.12.5 Relative Humidity History .............................................. 49 5.12.6 Water Consumption History ........................................... 50 5.12.7 Heater Run Time History................................................ 50 5.13 ALARM SETTINGS.......................................................... 52 5.13.1 Alarm Log.................................................................... 52 5.13.2 Setting Alarm Limits ...................................................... 53 5.13.2.1 Adjusting Hi/ Lo Temperature Alarms................................. 54 5.13.2.2 Adjusting Critical Temperature......................................... 55 5.13.2.3 Adjusting the Outside Temperature Influence..................... 55 5.13.2.4 Adjusting Static Pressure Alarms ...................................... 56 5.13.3 Resetting the Alam Log.................................................. 58 5.14 INSTALLATION .............................................................. 59 5.14.1 Step-by-Step Installation Guide ...................................... 59 5.14.2 Password Settings ........................................................ 61 5.14.3 Installation Setup .......................................................... 63 5.14.4 Sensor Assignment...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias