Log:
Assessments - 3, GPA: 5 ( )

Instruções de Operação Gentek, Modelo 3950222

Fabricante : Gentek
Arquivo Tamanho: 1.29 mb
Arquivo Nome :
Língua de Ensino:
Ir para baixar



Facilidade de uso


40E 2, 1" Long 3788200 Snubber, Filter Pressure Gauge 41A 1 1289101 115V Relay (for Remote Blower on XPert Filtered Station) 41B 1 1289102 230V Relay (for Remote Blower on XPert Filtered Station) 42 1 3925600 Harness, Relay (for Remote Blower on XPert Filtered Station) 76 Appendix A: Replacement Parts s Use for XPert System and XPert Station 23 17 22 26 7 21 32 35 31 33 Placed on ledge above HEPA filter 34 24 25 28 29 30 36 9 11 1 10 63 4 5 12 14 13 40 19 18 8 16 20 2 77 Appendix A: Replacement Parts ppendix A: Replacement Parts Use for XPert System, XPert Station, Digital Monitor and Bag 37 38 37 8 37 39 Needs to be sealed on XPert Station 37 19 Ships uninstalled as shown 20 18 23 32 42 Location only Not shown 41, Location only Not shown 78 A AAP PPP PPE EEN NND DDI IIX XX B BB D DDI IIM MME EEN NNS SSI IIO OON NNS SS A AAN NND DD E EEX XXH HHA AAU UUS SST TT O OOP PPT TTI IIO OON NNS SS See the following dimensions and exhaust options for all the XPert Filtered Balance Systems and XPert Filtered Balance Stations. Appendix B: Dimensions and Exhaust Options ppendix B: Dimensions and Exhaust Options Figure B-1 XPert Filtered Balance System 80 Appendix B: Dimensions and Exhaust Options s Figure B-2 XPert Filtered Balance Station 81 Appendix B: Dimensions and Exhaust Options ppendix B: Dimensions and Exhaust Options Figure B-3 Exhaust Duct connection Kit (Optional Installation on Integral Blower Models such as the XPert Filtered Balance System) 82 A AAP PPP PPE EEN NND DDI IIX XX C CC F FFI IIL LLT TTE EER RRE EED DD E EEN NNC CCL LLO OOS SSU UUR RRE EE S SSP PPE EEC CCI IIF FFI IIC CCA AAT TTI IIO OON NNS SS This Appendix contains technical information about all the XPert Filtered Enclosures including electrical specifications, environmental operating conditions and wiring diagrams. • 3 Amps, 115V or 2 Amps, 230V, 50/60 Hz, XPert Filtered Balance System and XPert Filtered Balance Station. Environmental Conditions • Indoor use only. • Maximum altitude: 6562 feet (2000 meters). • Ambient temperature range: 41° to 104°F (5° to 40°C). • Maximum relative humidity: 80% for temperatures up to 88°F (31°C), decreasing linearly to 50% relative humidity at 104°F (40°C). • Main supply voltage fluctuations not to exceed ±10% of the nominal voltage. • Transient over-voltages according to Installation Categories II (Over-voltage Categories per IEC 1010). Temporary voltage spikes on the AC input line that may be as high as 1500V for 115V models and 2500V for 230V models are allowed. Appendix C: Filtered Enclosure Specifications ppendix C: Filtered Enclosure Specifications • Used in an environment of Pollution degrees 2 (i.e., where normally only non-conductive atmospheres are present). Occasionally, however, a temporary conductiv...

Este manual também é adequado para os modelos :
Libra - 3940322 (1.29 mb)
Libra - 3940200 (1.29 mb)
Libra - 3940201 (1.29 mb)
Libra - 3940202 (1.29 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias