Turn off the power, and then turn it back on. If the error persists after this, consult your dealer. Error No. Details of error VTR operation E-11 When the cassette was inserted, the reel motor locked up for about 2.5 seconds or longer. When the cassette is ejected, the VTR is set to the auto OFF mode. STOP E-21 When the cassette was removed, the front loading motor locked up for about 4 seconds. When the cassette moves down again and the motor locks up again even if an attempt is made to remove the cassette, the VTR is set to the auto OFF mode if the cassette has moved down. STOP STOP E-31 The loading motor locked up for about 4 seconds when the cassette was loaded. If the motor locks up even when the cassette is unloaded and loaded again, the cassette is ejected. The VTR is set to the auto OFF mode. STOP E-32 The motor locked up for about 4 seconds when the cassette was unloaded. The VTR is set to the auto OFF mode. STOP E-41 The FG (rotational speed) signal is not output from the cylinder motor. STOP E-42 The PG (phase speed) signal is not output from the cylinder motor. STOP E-43 The cylinder motor speed is abnormally high. STOP E-44 The cylinder motor speed is abnormally low. STOP E-51 The FG (rotational speed) signal is not output from the capstan motor. STOP E-52 The capstan motor speed is abnormally high. STOP E-53 The capstan motor speed is abnormally low. STOP E-61 The supply reel motor has locked up. STOP E-62 The take-up reel motor has locked up. STOP E-63 The supply reel motor speed is abnormally high. STOP 69 Error messages ERROR MESSAGES Error No. Details of error VTR operation E-64 The take-up reel motor speed is abnormally high. STOP E-65 Abnormal tension has been detected. STOP E-66 At the tape start or end, the short FF or REW operation does not stop even after 7 or more seconds. STOP E-67 A check sum error was detected in the serial data communication between the syscon and servo. STOP E-68 In serial data communication between the syscon and servo, the data was fixed at low or high and the absence of data was detected. STOP E-69 A communication error was detected in the serial data between the syscon and servo when the power was turned on. STOP E-70 About an hour has elapsed after the fan motor stopped. The VTR forcibly turns off its power. Forced POWER OFF E-71 The heat sensor was activated and an abnormally high temperature inside the VTR was detected. Forced POWER OFF E-72 Trouble in the solenoid drive circuitry was detected. Forced POWER OFF E-73 Trouble in the cleaning solenoid drive circuitry was detected. Forced POWER OFF E-BA The input supply voltage dropped below the undercut voltage. Forced POWER OFFO (*) The counter display flashes to provide a warning. 70 DIAG-MENU OPERATIONS The unit’s system software version display, hour meter displays for the drum motor, rotating heads, etc. (for number of hours used can be viewed on the DIAG menu. DIAG-MENU HOUR METER