Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Panasonic, Modelo AWPH400

Fabricante : Panasonic
Arquivo Tamanho: 1.49 mb
Arquivo Nome : AWRP400.PDF
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Only one camera can be controlled from the WV-CB700A. If there is a multiple number of cameras, one AW-CB700A will be required for each camera. It is also necessary to align the number of the CONTROL OUT TO PAN/TILT HEAD connectors connected to the cameras to be controlled with the CAMERA CONTROL IN FROM RCB connectors used to connect the WV-CB700A. . Use the 10BASE-T straight cable to connect the MONI SEL OUT connector on the AW-RP400 with the MONI SEL IN connector on the AW-RC400. The maximum extension distance is 50 meters when using a UTP category 5 cable or its equivalent. By connecting these MONI SEL connectors, the video signals of the camera selected by the AW-RP400 can be output from the MONITOR1 connector and the video signals of the camera selected by the AW-CB400 can be output from the MONITOR2 connector. When the WV-CB700A is used, MONITOR2 cannot be switched. . Use a coaxial cable to connect the AW-RC400 and AW-PH400. . Supply the genlock signals from a unit such as a signal generator to the G/L IN connector on the AW-RC400, and connect the G/L OUT (1 to 5) connectors on the AW-RC400 with the G/L IN connectors on the pan/tilt heads. . When using composite signals, connect the VIDEO connectors on the pan/tilt heads and Y/VIDEO IN connectors (1 to 5) on the AW-RC400. Also connect the Y/VIDEO OUT connectors on the AW-RC400 to switchers or monitors. . When using Y/C signals, connect the Y connectors and Pr/C connectors on the pan/tilt heads to the Y/VIDEO IN connectors and Pr/C IN connectors, respectively, on the AW-RC400. Also connect the Y/VIDEO OUT connectors and Pr/C OUT connectors on the AW-RC400 to switchers or monitors. . When using component signals, connect the Y connector, Pr/C connector and Pb connector on the pan/tilt head to the Y/VIDEO IN connector, Pr/C IN connector and Pb IN connector, respectively, on the cable compensation unit. Also connect the Y/VIDEO OUT connectors, Pr/C OUT connectors and Pb OUT connectors on the AW-RC400 to switchers or monitors. 49 Connections Motorized zoom lens Camera cable supplied with AW-PH400 Video signal output Genlock signal input Iris control Convertible camera Genlock signals Video signals Monitor switching signals Monitor signals 1 Monitor for AW-CB400 Monitor for AW-RP400 Monitor signals 2 Zoom/focus control AW-PH400 Indoor Pan/Tilt Head Pan/tilt head/camera control signals AC power cable supplied with AW-PH400 AW-RP400 Pan/tilt control panel AW-CB400 Remote Operation Panel Cable supplied with AW-CB400 (AW-CB400 power and camera control signals) AW-RC400 Cable Compensation Unit AW-PS505 AC adaptor AW-PS301 AC adaptor 50 Example of system configuration AW-PH400 To switcher, monitor AW-PS301 AC adaptor Convertible camera MONITOR1 Monitor Monitor Cable provided with AW-CB400Monitor switching AW-RC400 Cable Compensation Unit AW-PS505 AC adaptor Pan/Tilt Control Panel AW-RP400 Remote Operation Panel AW-CB400 Headset Headset MONITOR2 Pan/tilt head and camera control Indoor Pan/Tilt Head Composite video or component video signals Genlock signals G/L 51 Operating procedures $ Turning on the power 1 When using one AW-RP400, set its EXT CONT [M/S] switch to the [M] position. When two AW-RP400 units are used, set the EXT CONT [M/S] switch on the AW-RP400 to which the pan/tilt head is connected to the [M] (master) position and the switch on the AW-RP400 to which the pan/tilt head is not connected to the [S] (slave) position. 2 Turn on the power. Follow the sequence below to turn on the power when one AW-RP400 is going to be used: Set the power switch of the AC adaptor used for the AW-RP400 and the AC power switch on the AW-PH400 to [ON], set the OPERATE switch on the AW-CB400 to [ON], and then set the OPERATE switch on the AW-RP400 to [ON]. Follow the sequence below to turn on the power when two AW-RP400 units are going to be used: Set the OPERATE switches of the AW-CB400 and of the AW-RP400 set as the slave to [ON], and then set the OPERATE switch on the AW-RP400 set as the master to [ON]. $ Setting the movement range (limiters) of the AW-PH400 indoor pan/tilt head If there are any objects obstructing the movement of the AW-PH400 indoor pan/tilt head in the immediate vicinity, set restrictions on the movement range (limiters: left, right, top and bottom limits of rotation). When the AW-RL400 roll unit is connected to the AW-RP400, set the movement limits (clockwise and counterclockwise limits) of the roll unit as well. Before using these units, set these limits without fail. . When it is shipped, the AW-PH400 is set up to be placed on a stand or base. If it is to be suspended from the ceiling, the mounting direction switch must be set without fail. If this setting is not performed correctly, the directions of the pan/tilt operations will be reversed, and the movement range (limiter) settings of the pan/tilt head will not be stored in the memory properly. For details on the setting methods and related aspects, refer to “Setting the mounting direction switch...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias