Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Panasonic, Modelo GPKS1000

Fabricante : Panasonic
Arquivo Tamanho: 647.1 kb
Arquivo Nome : GPKS1000.PDF
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Adjust the tilt angle and rotation of the camera head and secure the camera and camera holder by tightening the screw. 3. Rotate the focus lock ring fully. Mount the lens and C-mount adaptor by rotating them clockwise slowly. Focus Lock Ring Marker {Red, Green, Blue) ft 3. Install the camera with camera holder onto the tripod or other mounting bracket. Caution: If the optional C-mount lens size exceeds 50mm (2") in diameter, 70mm (2-3/4”) in length and 300g (0.66 lbs) in weight, both the camera and lens should be secured. Caution: If the optional C-mount lens size exceeds 50mm (2”) in diameter, 70mm (2-3/4”) in length and 300g (0.66 lbs) in weight, both the camera and lens should be secured. -7- CONNECTIONS CAUTIONS: • Keep the DC Power ON / OFF Switch in the OFF position until all connections have been properly made. • Connect the camera head and camera control unit which are packed in the same box (a pair) otherwise it would be cause improper operation. Internal Sync Operation 1. Connect the camera cable between the camera head and the camera control unit. 2. Connect the coaxial cable with BNC connectors between the Video Output Connector of the camera control unit and the video monitor or VCR. Video Monitor VCR or Video Monitor Caution To prevent fire or electric shock hazard, the UL listed wire VW-1, style 1007 should be used for the cable for 12V DC Input Terminals. Gen • lock Operation 1. Connect the camera cable between the camera head and the camera control unit. 2. Connect the coaxial cable with BNC connectors between the Video Output Connector of the camera control unit and the Video Input Connector of Special Effects Generator (SEG), and between the G/L Input Connector of the camera control unit. ccu 3. Connect the power cable between the DC 12V Input Terminals and the 12V DC power supply unit (obtained locally). • Calculation method of maximum cable length between camera control unit and the power supply unit is as follows: 10.5V DC < VA - (R x 0.42 x L) < 16V DC L: Cable length (meter) R: Resistance of copper wire (ohms / meter) VA: DC output voltage of power supply unit L standard = VA -12 / 0.42 x R (meter) L minimum = VA - 16 / 0.42 x R (meter) L maximum = VA -10.5 / 0.42 x R (meter) 3. Connect the power cable between the DC 12V Input Terminals and the 12V DC power supply unit (obtained locally) CAUTION CONNECT THIS TO A 12V DC CLASS 2 POWER SUPPLY ONLY. Caution To prevent fire or electric shock hazard, the UL listed wire VW - 1, style 1007 should be used for the cable for 12V DC Input Terminals. CAUTION CONNECT THIS TO A 12V DC CLASS 2 POWER SUPPLY ONLY. -8- USER FILE SETTING It is available to use the user preference stored by selecting user switch. 1. Remove the switch cover on the rear of the camera control unit by removing a screw. AGC/ELC Sensing Zone (Item No. 7) 0:ALL 1:CENTER 2:S CIRCLE 3:M CIRCLE 4:L CIRCLE a> ~ o « 8 8 m 2. Select desired user file (1 - 4) by rotating the User Switch 3. Set User File Set On/Off Switch on the rear panel to ON. 4. Select desired item to change by rotating the User File Item Switch @ . The item number indicates item shown below. Note: Item 1 and 2 settings are not stored at each user file distinctively. 5. Select or adjust the level of the desired item by the User File Select Switch @> or User File Adjust Control 6. Press User File Set Switch © to memorize the set level. 7. Repeat the above procedures 4 to 6 to set the other items. 8. After all the settings finished, set User File Set On/Off Switch to off. 9. Place the switch cover onto the rear of the camera control unit and tighten with a removed screw. Item No. Item Adjust control ©i Select switch @ 0 G/L H Phase Valid Invalid 1 G/L SC Coarse/Phase Valid Valid 0:0° 1:90° 2:180° 3:270° 2 DTL Level Valid Invalid 3 Chroma Gain Valid Invalid 4 Color Matrix (R-G) Valid Invalid 5 Color Matrix (B-G) Valid Invalid 6 Pedestal Level Valid Invalid 7 AGC/ELC Sensing Zone Invalid 0: ALL 1: CENTER 2: S CIRCLE 3: M CIRCLE 4: L CIRCLE 8 (NC) ^--- 9 Reset All Settings Invalid Invalid — Caution- Do not set User File Item Switch @ to the position.A to F. If the setting (A to F) is made, select both User File Item Switch @ and User File Select Switch <3> to the position F, then press User File Set Switch ©. PREVENTION OF BLOOMING AND SMEAR When the camera is aimed towards spotlights or other bright lights or light reflecting objects,’ smear or blooming may appear. Therefore the camera should be carefully in the vicinity of extremely bright objects to avoid smear or blooming. If the camera is aimed at the sun or very bright light, such as laser beam, for a long period of time, the CCD image sensor may be burned in and blemishes (white or black dots) appears on the monitor screen. -10- SPECIFICATIONS Image Sensor : Pixels : Scanning Standard Video Outputs: 1 / 2“ interline transfer (IT) CCD image sensor ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias