Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Panasonic, Modelo WJSQ508

Fabricante : Panasonic
Arquivo Tamanho: 1005.71 kb
Arquivo Nome : WJSQ508.PDF
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This menu is for programmed sequential switching when operating the Program Switch (20). • When this menu is selected, the channel (CH) for order number 1 blinks. Select which channel (camera) will occupy order number 1 by using the Backward Character Selection Switch (15) and the Forward Character Selection Switch (16). • Press this Right Shift Switch (13). The DWELL blinks. Set the dwell time of the sequential switching by using the Backward Character Selection Switch (15) and the Forward Character Selection Switch (16). The dwell time can be set from 0.5 sec. to 30.0 sec. in 0.5 sec increments. ORDER CH DWELL (S) BYPASS 1 1 2 PASS 2 3 2 * 3 5 2.5 * 4 7 3 * 5 2 2 * 6 4 1.5 * 7 6 3.5 * 8 8 3 * • Press the Right Shift Switch (13). The BYPASS blinks. • Select ’’PASS” or by using the Backward Character. Selection Switch (15) or the Forward Character Selection Switch (16). When "PASS" is selected, the camera of this channel will be skipped. When the is selected, the camera of this channel will be included in the a sequential operation. • Repeat above procedure for all cameras. • After the setting up has been done, press the Enter Switch (11) to memorize the new menu and then press the Program/End Switch (17) to conclude the programming of the menu. -10- Note: 1. The example illustrated above performes sequential switching of the cameras in the following order: 1 —► 3 —► 5 —► 7 —» 2 —► 4 —► 6 —► 8 with a corresponding dwell time. 2. If a "CH" number has been set twice, an arrow mark points out the lower "CH’’ to be corrected. ORDER CH DWELL (S) BYPASS 1 1 2 PASS 2 3 2 * 3 5 2.5 * 4 7 3 * 5 2 2 * 6 4 1.5 ♦ 7 3 «- 3.5 # 8 8 3 * CONNECTION WITH ALARM UNIT & TIME LAPSE VTR • Connect the sensor switches and the Time Lapse VTR with the proper cables. The sensor should have an open-collector output or non-voltage contact, (Time Lapse VTR) ALARM | IN GND RESET IN RECOVER OUT GND OUT GND © (WJ-SQ508) Alarm switch 1 to 8 When the alarm time of the Time Lapse VTR is set shorter than the Sequential Switcher WJ-SQ508, the alarm mode of the Time Lapse VTR will be finished faster than the Sequential Switcher. At this time, the Time Lapse VTR will cease the alarm mode of the Sequential Switcher. When the alarm signal is supplied to the WJ-SQ508, the letters of "AL" blinks on the video monitor through the Alarm/Sequence Video Output Connector (22) or the Spot/Sequence Video Output Connector (23). When the alarm unit has to be connected with the Alarm Output Connector (39), refer to the diagram below. The capacity of the Alarm Output Connector (39) is 16V DC maximum 100mA or less. Use a Relay Box if necessary. ALARM OUT C: Common -11- HOW TO SET UP THE UNIT NUMBERS Important Before the actual installation and wiring of the system components has been made, you are strongly recommended to draw a complete system diagram to set up the Station number, Unit number, position of the CH SELECT, signal flow of the Data Clock and other necessary switches. Keep this diagram and refer it when the more components are installed to expand the system. The Bay System in Advanced Application-3 will be used as an example to explain the setting up the unit numbers. (See page 25.) • In this system, sixty-four (64) cameras, five (5) WV-CU300, twenty-four (24) WJ-SQ508 and four (4) WJ-MP404 are used. • Cameras No.1 to No.16 are observed by Satellite A, Cameras No,17 to No.24 are observed by Satellite B, Camera No.25 to No.64 are observed by Satellite C. The Master Location & Sub Location observe the all cameras and the Master Location has a primary control right to the master-slave Sequential Switchers. • The Unit Number Table on this page shows the full loaded system with 64 cameras. 16 WJ-MP404, 24 WJ-SQ508, and 5 WV-CU300. 8 cameras (No.1 to No.8) are being supplied to 2 WJ-MP404 {No.1 and No,2). These 2 WJ-MP404 are connected with a WJ-SQ508 which has a station number-1 with 8 video cables. These 8 video signals are supplied to another WJ-SQ508 which has a station number-3 by looping-through another WJ-SQ508 which has station number-2. The last 8 cameras (No.57 to No.64) are supplied to 2 WJ-MP404 (No.15 and No.16). These 2 WJ-MP404 are connected with a WJ-SQ508 which has station number-1 with 8 video cables. These 8 video signals are supplied to another WJ-SQ508 which has station number-3 by loopeding-through another WJ-SQ508 which has station number-2. 1) Compare the Unit Number Table with the Advanced Application-3 on page 25. 2) Controller Unit Number Assign a different controller unit number for each WV-CU300 by using the Controller Number Selection Switch (43). 3) Station Number The station number of WJ-SQ508 is assigned as indicated in the following procedure. • The WJ-SQ508 which are connected to the cameras directly or to the WJ-MP404 should have station number '1". • The WJ-SQ508 which receive the looped-through video signals from station number 1 should be assigned the st...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias