Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Panasonic, Modelo WVBP120

Fabricante : Panasonic
Arquivo Tamanho: 362.21 kb
Arquivo Nome : WVBP120.PDF
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If not, both the lens and camera should be secured. The protrusion of the rear of the lens should be as shown below. -1 C-mount: Less than 11.5 mm (7/16”) CS-mount: Less than 7,2 mm (1/4”) Caution: Always set the Flange-back adjusting ring to fully clockwise (Omount side) by loosing screws on the ring before mounting the lens, otherwise the inner glass and CCD image sensor could be damaged by the lens. (1) Mount the lens by turning it clockwise onto the lens mount of the camera. (2) Connect the lens cable to the Auto Iris Lens Connector on the camera when an auto iris lens is used. (3) Set the Lens Selection Switch to the proper position as follows. DC: The mounted lens, is one of the lenses listed on pages 9, 10 and 11 or one that requires the DC control signal for auto iris control. VIDEO: The mounted lens requires video signal for auto iris control. Note: Refer to item on page 5 for the lens selection switch. FOCUS OR FLANGE-BACK ADJUSTMENT The following adjustment should be made by qualified service personnel or system installers. 1. Loosen screws on the flange-back adjusting ring. Focus adjust for 2. Turn the flange-back adjusting ring to the desired position. Caution: Do not turn this ring too much to counterclockwise as this could damage the inner glass and CCD image sensor. 3. Tighten the screws on the flange-back adjusting ring. Note: Do not apply the excessive torque (0.5 kg.cm, recommended) to the screws on the flange-back adjusting ring.) INSTALLATION OF CAMERA • Mounting from the bottom This camera is originally designed to be mounted from the bottom as shown. The hole is the standard photographic pan-head screw size (1/4‘ -20). • Mounting from the top Remove the mount adaptor from the bottom of the camera by removing two fixing screws. Attach the mount adaptor to the top as shown in the diagram, then mount the camera on the mounting bracket. Make sure that two original screws are used when mounting the mount adaptor; longer type screws may damage inner components. PREVENTION OF BLOOMING AND SMEAR When the camera is faced toward spot light or other bright lights and light reflecting objects, smear or blooming may appear. Therefore, the camera should be operated carefully in the vicinity of extremely bright objects to avoid smear or blooming. Smear ■Bright object LENS MAINTENANCE AND CLEANING 1. Remove the lens connector 2. Remove the lens, and inspect the camera CCD faceplate through the lens mount opening to assure that the faceplate is free of smudges or particles of dirt. 3. Clean the CCD faceplate, if necessary, using lens tissue or a cotton tipped applicator and ethanol. 4. Install the new lens. 6- SPECIFICATIONS Pick-up Device: Scanning Area: Synchronization: Scanning System; Scanning: Horizontal: Vertical: Horizontal Resolution: Video Output: Signal-to-Noise Ratio: Automatic Light compensation: Electronic Light Control: Minimum Illumination: Lens Mount: Ambient Operating Temperature Ambient Operating Humidity: Power Source: Power Consumption: Dimensions (without lens): Weights (without lens): 512 (H) x 492 (V) pixels. Interline Transfer CCD 4.8 (H) x 3.6 (V) mm (Equivalent to scanning area of 1/3" pick-up tube) Line-locked mode or switchable Multiplexed Vertical Drive (VD2) automatically 2 : 1 interlace 525 lines/60 fields/30 frames 15.75 kHz . 60 Hz 380 lines 1.0 V[p-p] composite,75£'2/BNC connector 46 dB ALC : 1 : 10,000 with F1.4 ALC lens Equivalent to continuous variable shutter speed between 1/60 s and 1/80,000 s 0.15 Ix at F1.4, AGC ON C-mount or special C-mount (CS-mount) -10°C - +50°C (14°F - 122°F) Less than 90% WV-BP120 120V AC 60 Hz WV-BP124 24V AC 60Hz WV-BP120 2.8W WV-BP124 2.7W ' 67 (W) x 65 (H)x 123 (D) mm [2-5/8" (W) x 2-9/16” (H) x 4-13/16" (D)] WV-BP120 600 g (1.3 lbs.) WV-BP124 450 g (1.0 lbs.) Weights and dimensions indicated are approximate. Specifications are subject to change without notice. STANDARD ACCESSORIES ALC Lens Connector (YFE4191J100) ....................1 pc. Body Cap .............................................................1 pc. OPTIONAL ACCESSORIES Lenses : WV-LA2.8, WV-LA6B2, WV-LA12B2 WV-LA18, WV-LA36, WV-LA4510 VW-LA608, WV-LA1208, WV-LA4R5C3A VW-LA9C3A, WV-LZ61/10 WV-LZ81/6, WV-LZ81/10, WV-LZ83/6 WV-LM4R5A, WV-LM6B2, VW-LM12B2 WV-LF4R5C3A. WV-LF9C3A -18- Panasonic Broadcast & Television Systems Company Division of Matsushita Electric Corporation of America IMAGING SYSTEMS DIVISION Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: „ Northeast: 43 Hartz Way, Secaucus, NJ 07094 (201) 348-7303 Southeast: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30174 (770) 338-6835 Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5200 Southwest: 4500 Amon Carter Blvd., Fort Worth, TX 76155 (817) 685-1117 Western: 6550 Katelia Ave. 17A-5, Cypress, CA 90630 (714) 373-7265 MATSUSHITA ELECTRIC OF CANADA LIMITED 5770 Ambler Dri...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias