|
por este dispositivo também tem outras instruções :
Facilidade de uso
Connect the AUDIO OUT A or B connectors on the monitor to the audio input of the VCR with an audio cable, if applicable. • Monitoring the Playback picture Connect the video output of the VCR to the VIDEO IN A or B connector on the monitor with a coaxial cable. • Monitoring the Playback audio Connect the audio output of the VCR to the AUDIO IN A or B connector on the monitor with an audio cable. 6 ■ Multiple Monitor Connection To monitor the same video on multiple monitors, connect the VIDEO OUT A or B connector on the monitor to the VIDEO IN connector of the other monitor with a coaxial cable. Up to 10 monitors can be connected in series before signal loss occurs. Total cable length should not exceed 150 meters (500 feet). ■ Connection to the Standby On/Off Terminal Connecting an outboard device to the STANDBY ON/OFF Terminal on the rear of the monitor enables control of the monitor display by input from that device, both in normal and standby display mode. Shown below is an example of how to use this function. ■ Connection with the System Controller If the optional 6-conductor cable assembly is used, simply plug one end of the cable into the DATA port of the Monitor and the other end into the DATA port on the System Controller. If you use cables assembled from locally procured materials, it is important that only high quality, data grade cable, suitable for RS-485 communication (shielded 4-wire twisted pair cable), BELDEN 9406 or equivalent, is used. Lower grade cable will result in unstable operation of the system. DATA DATA n°DI 0° IQ -1 IrSI 1-1 '-1 Ip 1-1 STANDBY ON STANDBY OFF Alarm Output Alarm Reset Output Vh%5V Vl^0.2 V STANDBY ON input Pulse +5 V DC STANDBY OFF input Non-voltage contact or open collector output Note: To set up this function, refer to STANDBY ON in the Display Setting menu. • Setting the Termination Set the Termination Selector located on the rear of the monitor according to your requirements. ON: Data is terminated. OFF: Data is sent to other equipment. 7 SETUP PROCEDURES This monitor offers various onscreen menus for setting user preferences. In the COMMUNICATION SETUP Menu, you can set the parameters for communication between the System Controllers and the Monitors. ■ Displaying the Setup Menu To display the Setup Menu, follow the procedure shown below. 1. Confirm that the cameras and peripherals are connected correctly and securely. 2. Turn the power of the monitor on by pressing the POWER button. 3. Press the MENU button for 5 seconds or more. At first the Display Setting menu described on page 10 appears, and then the COMMUNICATION SETUP menu shown below. t-^ COMMUNICATION SETUP UNIT ADDRESS 111 CAM CONFIG BAUD RATE 9600 DATA BIT e PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF SETUP DISABLE The following buttons are valid in this Setup menu. A: Moves the cursor up. ▼: Moves the cursor down. E): Selects the mode or parameter. 0: Selects the mode or parameter. 4. To finalize the settings and return to normal viewing, press the MENU button. ■ Setup Menu As shown above, the Setup Menu has seven main submenus. One of these, CAM CONFIG, is further divided into additional submenus. 1. After selecting the Setup Menu on the monitor screen, move the cursor to SETUP DISABLE by pressing the A or T button, then press the 0 or 0 button. Display of SETUP ENABLE in the Setup menu indicates that setup is enabled. '-- COMMUNICATION SETUP UNIT ADDRESS 1 CAM CONFIG "I BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF SETUP ENABLE! 2. Move the cursor to the desired item by pressing the A or ▼ button. 3. Select the desired item parameter by pressing the 0 or 0 button. 4. Press the MENU button to store the settings and return to normal viewing • Unit Address (UNIT ADDRESS) This item lets you set the unit address of the monitor in the system for RS-485 communication. 1. Move the cursor to the UNIT ADDRESS parameter by pressing the the A or T button. /- > COMMUNICATION SETUP UNIT ADDRESS 111 CAM CONFIG '■* BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF SETUP ENABLE L —> 2. Select the unit address number to be used for RS-485 communication by pressing the 0 or 0 button. Select a parameter value between 1 and 99. The factory default setting is 1. 8 • Camera Configuration (CAM CONFIG) This item lets you set numbers for the input from system cameras for RS-485 communication. 1. Move the cursor to CAM CONFIG by pressing the A or ▼ button, then press the 0 or 0 button. The CAMERA CONFIG menu shown below will appear on the monitor screen. /- COMMUNICATION SETUP UNIT ADDRESS 1 Tcam Iconf ig U* BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF SETUP ENABLE CAMERA CONFIG INPUT CH CAM NO. A CH :oon B CH 002 S-VIDEO 003 v_ _/ 2. Move the cursor to the input parameter to be edited by pressin...