The 4-bit DIP switch is used for ON RS485 termination. 1234 4-bit DIP SW Fall Prevention Wire BP 1 Function Switch ON Termination ON position OFF Termination OFF * BP 2 BP 3 BP 4 Function Switch ON ON ON Half duplex (2 line) position OFF OFF OFF Full duplex (4 line) * Notes: • Defaults are marked with *. • BP stands for Bit Position. • Full duplex is not available in a daisy chain connection. (Panasonic system controllers only) 5. Mounting the camera (1) Aim the "START" arrow at the bent portion of the leaf spring. Bending Leaf Spring START (3) Fix the camera to the upper base. • Move the camera up so that its guide pins fit into the guide holes of the upper base. • Turn the camera counter-clockwise to the end, viewed from the bottom. • Fasten 3 screws. x3 Screws Upper Base Enclosure -50 CONNECTIONS Precautions • The following connections should be made by qualified service personnel or system installers in accordance with all local codes. • Switch the 24 V AC power source off before installation and connection. Note: When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing opera- tion). To VIDEO IN (CAMERA IN) Video output 24 V AC BNC plug Coaxial cable RS485 cableData port BNC plugAlarm in Alarm out To sensors To indicators 24 V AC cable for Camera 24 V AC cable for Heater . The coaxial cable length (RG-6/U, 5C-2V) for the connection is up to 1 200 meters (4 000 ft.) • 24 V AC Power Supply Connection Recommended wire gauge sizes for 24 V AC line Copper wire size (AWG) #24 (0.22mm2) #22 (0.33mm2) #20 (0.52mm2) #18 (0.83mm2) Length of cable (approx.) (m) 20 30 45 75 (ft) 65 100 160 260 Accessory Connector Information Prepare the individual conductors for clamping. Use MOLEX band tool part number 57027-5000 (for UL- Style Cable UL1015) or 57026-5000 (for UL-Style UL1007) for clamping the contacts. After clamping the contacts, push them into the proper holes in the accessory connector of this camera until they snap in place. Up Wire Pin no. Power source 1 24 V AC LIVE 2 24 V AC NEUTRAL 3 Ground 4 Not use 1324 How to Assemble the Cable with the Accessory Connector Strip back the cable jacket approx. 3 mm (0.1 inch) and separate the individual conductors. Approx. 3 mm (0.1 inch) Wire Contact CAUTIONS • Shrinking the cable-entry seal is a one-time procedure. Do not shrink the cable-entry seal until it has been ascertained that the unit is functioning. • CONNECT THIS TO 24V AC CLASS 2 POWER SUPPLY ONLY. Insert AUp Contact Insert the wire until A position and clamp the contacts. -51 • RS485 Connection Data transmission Data reception Brown GND Red T (B) Orange T (A) Yellow R (B) Green R (A) Note: Alarm OUT (4-pin) Use the cable that is described below for RS485 site communication. • Shielded, twisted pair cable • Low impedance • Wire gauge size is thicker than AWG #22 (0.33 mm2). Wire color Function Gray White Pink Yellow green or light blue OUT 1 GND OUT 2 GND • ALARM IN Connections Note: Use a relay if the voltage or current of the con- An 8-pin and a 4-pin harness are supplied with the nected device exceeds the ratings. camera as standard accessories. Connect external sensors to this connector. Input specifications are low-active, non-voltage contact (ON when active) or open collector (Low when active). The table below shows wire colors versus pin functions. Alarm IN (8-pin) Wire color Function Black IN 1 Brown GND Red IN 2 Orange GND Yellow IN 3 Light blue or green GND Blue IN 4 Purple GND • ALARM OUT Connections Connect an external device, for example, a buzzer or lamp, to this connector. Output specifications are low-active, open-collector and a drive capacity of 16 V DC 100 mA maximum. The table below shows wire colors versus pin functions. -52 SYSTEM CONNECTIONS Note: When any peripheral is turned off and turned on again, the camera is also turned off and turned back on. -53- 1 2 3 4 5 6 7 8 9 MON CAM ESC SET 0 ACK RESET BACK SEQ FORWARD SEQ ALT DEC –1CAM INC 1 2 +1CAM STOP AUX CLOSE OPEN IRIS PRESET FOCUS NEAR ZOOM TELE WIDE FAR System Controller WV-CU550B LEFT RIGHT UP DOWN ALARM BUSY F1 F2 F3 F4 AF 1 2 3 4 5 6 7 8 9 MON CAM ESC SET 0 ACK RESET BACK SEQ FORWARD SEQ ALT DEC –1CAM INC 1 2 +1CAM STOP AUX CLOSE OPEN IRIS PRESET FOCUS NEAR ZOOM TELE WIDE FAR System Controller WV-CU550B LEFT RIGHT UP DOWN ALARM BUSY F1 F2 F3 F4 AF 1 2 3 4 5 6 7 8 9 MON CAM ESC SET 0 ACK RESET BACK SEQ FORWARD SEQ ALT DEC –1CAM INC 1 2 +1CAM STOP AUX CLOSE OPEN IRIS PRESET FOCUS NEAR ZOOM TELE WIDE FAR System Controller WV-CU550B LEFT RIGHT UP DOWN ALARM BUSY F1 F2 F3 F4 AF 1 2 3 4 5 6 7 8 9 MON CAM ESC SET 0 ACK RESET BACK SEQ FORWARD SEQ ALT DEC –1CAM INC 1 2 +1CAM STOP AUX CLOSE OPEN IRIS PRESET FOCUS NEAR ZOOM TELE WIDE FAR System Controller WV-CU550B LEFT RIGHT UP DOWN ALARM BUSY F1 F2 F3 F4 AF Digital Disk Recorder WJ-HD Digital Disk Recorder WJ-HD Digital Disk Recorder WJ-HD Digital Disk Recorder WJ-HD Max. 64 cameras Monitors (up to 16) Printer System controller Digital disk ...