Log:
Assessments - 1, GPA: 3 ( )

Instruções de Operação BEA, Modelo Eagle HM

Fabricante : BEA
Arquivo Tamanho: 896.55 kb
Arquivo Nome : 47babf39-a477-4226-a5af-d8d6b0529b06.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


These adjustments can be made with BEA’s universal remote control. Other accessories available for the Eagle include the false ceiling adapter (ECA), and the rain protection cover (ERA). PRELIMINARY TECHNICAL SPECIFICATIONS Frequency: 24.125 GHz Supply voltage: 12 to 24 V AC : ± 10% : 12 to 24 V DC : -10% / +30% : Mounting height: 16.5 feet Tilt angle: 0° to 90° vertical -30° to +30° lateral Detection area: 13.1 ft x 8.2 ft Minimum detection speed: 2in/sec. (measured in axis) Power consumption: < 2 W Standard output relay: Max contact voltage Max contact current Max switching power 60 VDC / 125 VAC 1 A (resistive) 30W (DC) / 60VA (AC) Hold time: 0.5 sec. to 9 sec. (adjustable) Temperature range: -4°F to 131°F Dimensions: 4.75in (W) x 3.15in (H) x 2.0in (D) Weight: 0.5lbs Material: ABS Housing color: Black. Can be painted with non-metallic paint Cable length: 30ft DESCRIPTION OF THE SENSOR Terminal Block Wire Passage Hole Lateral Adj. For Antenna Manual Set-up Buttons Planar Antenna INSTALLATION TIPS .. The sensor must be .. The sensor must not be .. The sensor must not .. The sensor must not firmly fastened in order placed directly behind a have any object likely to have any fluorescent not to vibrate. panel or any kind of move or vibrate in its lighting in its sensing material. sensing field. field. 75.1038 V2 Aug 2001 [Rev. June 10, 2005] Page 1 of 8 SAFETY PRECAUTIONS • Shut off all power going to the header before attempting any wiring procedures. • Maintain a clean & safe environment when working in public areas. • Constantly be aware of pedestrian traffic around the door area. • Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door. • Always check placement of all wiring and components before powering up to insure that moving door parts will not catch any wires and cause damage to equipment. • Ensure compliance with all applicable safety standards upon completion of installation MECHANICAL INSTALLATION OPENING THE SENSOR From behind, before installation From the front, after installation MECHANICAL INSTALLATION PREPARATION FOR MOUNTING THE SENSOR .. Paste the template at .. Insert screws but do not screw .. If you don't want to drill your profile for desired location. .. Drill as instructed. them fully in. .. If possible, pass the cable the cable, you can cut the wire opening footprint as shown in the picture. where it is supposed to go through. ELECTRICAL INSTALLATION CABLING & CONNECTION 12-24 V AC/DC COM NO NC .. Run the cable through the wire .. Position the sensor and tighten passage hole just below PCB. the two screws. Make sure you leave enough cable to reach the terminal block. 75.1038 V3 Jun 2005 [Rev. June 10, 2005] Page 2 of 8 MECHANICAL ADJUSTMENTS - SETTING THE SENSING FIELD DIMENSIONS ADJUSTMENTS - SETTING THE SENSING FIELD DIMENSIONS A. WIDTH OF THE SENSING FIELD The antenna for the Eagle HM is identified by it’s 9 elements. There is no narrow or wide antenna. Only the 9 element antenna is utilized for the Eagle HM. B. THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL TILT ANGLE OF THE ANTENNA 0. 20. BA 27. C .. To obtain a sensing field as close to the door as possible : the tilt angle of the antenna must be set at the position (0°). - Example of use with a very deep operator. .. To obtain a sensing field close to the door: the tilt angle of the antenna must be set at the position (20°) - Example of use with a normal operator. Shown in Picture B above. .. To obtain a sensing field far from the door: the tilt angle of the antenna must be set at the maximum position (27°). - Example of use with a normal operator. Shown in picture C above. SENSING FIELDS ACCORDING TO THE VERTICAL TILT ANGLE OF THE ANTENNA The sensing fields on the right correspond to the following adjustments : .. vertical angle of the antenna : 0°, 20°, 27° ; .. sensitivity : 9 .. Mounting height: 16’ 6.4’ 3.2’ 0 3.2’ 6.4’ 0. 20. 27 0 3.2’ 6.4’ 9.6’ 12.8’ 16’ 75.1038 V3 Jun 2005 [Rev. June 10, 2005] Page 3 of 8 MECHANICAL ADJUSTMENTS - SETTING THE SENSING FIELD DIMENSIONS – Cont. ADJUSTMENTS - SETTING THE SENSING FIELD DIMENSIONS – Cont. 70. ..• For ceiling mounting, the vertical tilt angle of the antenna must be set at the maximum position of 70-75° and the spherical part of the sensor must be oriented in the opposite direction to the door. C. THE LATERAL POSITION OF THE SENSING FIELD IN FRONT OF THE DOOR IS DETERMINED BY THE LATERAL TILT ANGLE OF THE ANTENNA. +15.-15. 6.4’ 3.2’ 0 3.2’ 6.4’ The sensing fields on the right S=6 S=9 0 correspond to the following adjustments : 3.2 .. lateral angle of the antenna : 15°, -15° ; .. sensitivity : 6 (middle), 6.4 9 (max.) .. Mounting height : 16’ 9.6’ .. 20° Angle 12.8’ 16’ D. THE DIMENSIONS (WIDTH, DEPTH_OF THE SENSING FIELD DEPEND ON THE SENSITIVITY SETTING. The sensing fields on the right correspond to the following adjustments : .. vertical angle of the antenna : 20° .. Mounting height :16’ ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias