Instruções de Operação Munchkin, Modelo MUNCHKIN HIGH EFFICIENCY HEATER with the "925" Controller

Fabricante : Munchkin
Arquivo Tamanho: 1.09 mb
Arquivo Nome : ab2608d3-9198-48f8-aa66-5e891889388d.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


3. The minimum pipe size for connecting a Super Stor water heater is 1 inch. 4. The minimum pipe size for connecting a Munchkin boiler is 1.25 inches. 5. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. 6. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119°F. 7. Install a minimum of 12 diameters of straight pipe upstream of all circulators. 8. A purging valve may be used in lieu of the ball valve / hose bib combination shown. 9. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. cold water OFFOFFOFFOFF NOTE: FOR VISION PIPING APPLICATIONS, REFER TO THE VISION INSTALLATION PIPING DIAGRAMS. Fig. 5-6 PIPING Standard Munchkin boiler Preferred piping (zoning with circulators) Space heating mode NOTES: 1. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. 2. All closely spaced tees shall be within 4 pipe diameter center to center spacing. 3. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. 4. The minimum pipe size for connecting a Super Stor water heater is 1 inch. 5. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches. 6. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. 7. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119°F. 8. Install a minimum of 12 diameters of straight pipe upstream of all circulators. 9. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Munchkin boiler make-up water Super Stor indirect DHW tank closely spaced tees P1 P2 zone circulators T/P space heating zone circuit Drawing 2C purging valves anti-scald mixing valve cold water Standard Munchkin boiler Preferred piping (zoning with circulators) Space heating mode NOTES: 1. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. 2. All closely spaced tees shall be within 4 pipe diameter center to center spacing. 3. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. 4. The minimum pipe size for connecting a Super Stor water heater is 1 inch. 5. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches. 6. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. 7. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119°F. 8. Install a minimum of 12 diameters of straight pipe upstream of all circulators. 9. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Munchkin boiler make-up water Super Stor indirect DHW tank closely spaced tees P1 P2 zone circulators T/P space heating zone circuit Drawing 2C purging valves anti-scald mixing valve cold water NOTE: FOR VISION PIPING APPLICATIONS, REFER TO THE VISION INSTALLATION PIPING DIAGRAMS. Fig. 5-7 PIPING Standard Munchkin boiler Preferred piping (zoning with circulators) Domestic water heating mode Munchkin boiler make-up water Super Stor indirect DHW tank closelyspacedteesP2 zone circulators T/P space heating zone circuit Drawing 2D purging valves NOTES: 1. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. 2. All closely spaced tees shall be within 4 pipe diameter center to center spacing. 3. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. 4. The minimum pipe size for connecting a Super Stor water heater is 1 inch. 5. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches. 6. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. 7. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119°F. 8. Install a minimum of 12 diameters of straight pipe upstream of all circulators. 9. A purging valve may be used in lieu of the ball valve / hose bib combination shown. anti-scald mixing valve closely spaced tees P1 cold water Standard Munchkin boiler Preferred piping (zoning with circulators) Domestic water heating mode Munchkin boiler make-up water Super Stor indirect DHW tank closelyspacedteesP2 zone circulators T/P space heating zone circuit Drawing 2D purging valves NOTES: 1. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. 2. All closely spaced tees shall be within 4 pipe diameter center to center spacing. 3. A minimum of 6 pipe diameters of stra...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias