Instruções de Operação Burnham, Modelo MST288

Fabricante : Burnham
Arquivo Tamanho: 5.66 mb
Arquivo Nome : b22089b1-a241-4210-8bbf-e058170c1aa6.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


5. For boiler located in a confined space or an unconfined space in a building of unusually tight construction, provide outdoor air. a. Outdoor air for combustion may be provided with an optional Burnham Inlet Air Accessory Kit, Part Number 611280031 (only available and suitable for use on Beckett AFG with burner enclosure cover burner). See Section V for installation details. or b. Outdoor air may be provided with the use of two permanent openings which communicate directly or by duct with the outdoors or spaces (crawl or attic) freely communicating with the outdoors. Locate one opening within 12 inches of top of space. Locate remaining opening within 12 inches of bottom of space. Minimum dimension of air opening is 3 inches. Size each opening per following: i. Direct communication with outdoors. Minimum free area of 1 square inch per 4,000 BTU per hour input of all equipment in space. ii. Vertical ducts. Minimum free area of 1 square inch per 4,000 BTU per hour input of all equipment in space. Duct cross-sectional area shall be same as opening free area. iii. Horizontal ducts. Minimum free area of 1 square inch per 2,000 BTU per hour input of all equipment in space. Duct cross-sectional area shall be same as opening free area. Alternate method for boiler located within confined space. Use indoor air if two permanent openings communicate directly with additional space(s) of sufficient volume such that combined volume of all spaces meet criteria for unconfined space. Size each opening for minimum free area of 1 square inch per 1,000 BTU per hour input of all equipment in spaces, but not less than 100 square inches. 6. Louvers and Grilles of Ventilation Ducts a. All outside openings should be screened and louvered. Screens used should not be smaller than 1/4 inch mesh. Louvers will prevent the entrance of rain and snow. b. Free area requirements need to consider the blocking effect of louvers, grilles, or screens protecting the openings. If the free area of the louver or grille is not known, assume wood louvers have 20-25 percent free area and metal louvers and grilles have 60-75 percent free area. c. Louvers and grilles must be fixed in the open position, or interlocked with the equipment to open automatically during equipment operation. SECTION II: UNIT-PAK BOILER ASSEMBLY MegaSteam™ Unit-Pak Boiler Assembly Shipment Content Check List (see Figure 3) 1. ___ Cast Iron Section/Burner Swing Door/Smoke Box Assembly Mounted on Shipping Skid: ____ MST3 (Rear Section, Heater) – Part # 100566-03 / 100045-01 / 100021-01 ____ MST4 (Rear Section, Heater) – Part # 100566-04 / 100045-01 / 100021-01 ____ MST5 (Rear Section, Heater) – Part # 100566-05 / 100045-02 / 100021-01 ____ MST3 (Rear Section, Non-Heater) – Part # 100567-03 / 100045-01 / 100021-01 ____ MST4 (Rear Section, Non-Heater) – Part # 100567-04 / 100045-01 / 100021-01 ____ MST5 (Rear Section, Non-Heater) – Part # 100567-05 / 100045-02 / 100021-01 2. ___ Control Carton ____ CG450 LWCO; W/Tankless Heater - Part # 100608-01 ____ PS801 LWCO; W/Tankless Heater - Part # 100622-01 ____ #67 LWCO; W/Tankless Heater - Part # 100678-01 5. ____ Insulation Wrapper ____ CG450 LWCO; L/Tankless Heater - Part # 100680-01 ____ MST3 - Part #100614-03 ____ PS801 LWCO; L/Tankless Heater - Part # 100681-01 ____ #67 LWCO; L/Tankless Heater - Part # 100679-01 ____ MST4 - Part #100614-04 ____ MST5 - Part #100614-05 3. ___ Jacket Carton 6. ___ Instruction/Label Bag ____ MST3 – Part # 100609-03 ____ MST (All Models) – Part # 100617-01 ____ MST4 – Part # 100609-04 ____ MST5 – Part # 100609-05 7. ___ Oil Burner Carton ____ Beckett MST288 – Part # 100625-01 4. ___ Part Carton ____ Beckett MST396 – Part # 100053-01 ____ MST3 & 4 - Part # 100615-01 ____ Beckett MST513 – Part # 100054-01 ____ MST5 - Part # 100629-01 ____ Beckett MST629 – Part # 100055-01 Figure 3: MegaSteam™ Unit-Pak Boiler Shipment Contents (outside container removed) A. CAST IRON SECTION ASSEMBLY TAPPINGS Refer to Table 3 "Purpose of Tappings and Bosses" and Figure 7. 1. All tappings have factory installed thread protectors. The thread protectors must be removed prior to jacket and piping installation. 2. Depending of installation specifics and boiler build ordered, some tappings (front section Optional Front Return, rear section Indirect Heater Supply and Indirect Heater Limit) may not be used and must be plugged before jacket and piping installation. The appropriate size plugs for above mentioned tappings, as well as rear section Surface Blowoff and front section probe type LWCO tappings, are enclosed into Part Cartons (100615-01 or 100629-01) and Control Cartons (100678-01 and 100679-01), supplied as part of MegaSteam™ Unit-Pak Boiler shipment. B. REMOVAL OF CAST IRON SECTION/ BURNER SWING DOOR / SMOKE BOx ASSEMBLY FROM SKID. WARNING The Cast Iron Section/Burner Swing Door/Smoke Box Assembly has a substantial weight. Insure the travel path to permanent location, as well as mounting surface at boiler permanent location...

Este manual também é adequado para os modelos :
Aquecedores de Água - MST396 (5.66 mb)
Aquecedores de Água - MST513 (5.66 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias