Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação Rinnai, Modelo Q175SN

Fabricante : Rinnai
Arquivo Tamanho: 957.68 kb
Arquivo Nome :
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


Use only potable water for filling. Additives only after clearance by Rinnai. Contact your installer in case of doubt. Description of the boiler Description of the boiler RS100 The Rinnai Q boiler is a room sealed, condensing and modulating central heating boiler. The Q175C has an integrated domestic hot water feature. The boiler is provided with a integrated control system. Because an outdoor sensor is connected to the boiler, the boiler works weather dependantly. This means that the boiler control measures the outside temperature and flow temperature. With this data the boiler calculates the optimal flow temperature for the installation. When the boiler is connected to an RS100 room thermostat information can be retrieved from the boiler. For more information about the Rinnai thermostats. Please refer to the user manuals. On the bottom left side of the front panel there is a small door. Through the transparent panel you can see the boiler status on the display. After opening this door you will find the function buttons. On the following pages you will find the explanation of the function buttons and display messages. Operating Explanation of the function buttons 1 3 4 5 6 2 7 8 iExplanation of the function buttons 1 3 4 5 6 2 7 8 i NOTICE i NOTICE When the pump is switched on continuously it can lead to undesired heating up of the central heating system during the summer. i NOTICE Only qualified personel who are trained for these boilers are permitted to make alterations in the controller to chronolize the boiler to the installation. 1. Display. See following pages for further information. 2. ON-OFF Switch This switch turns the power supply to the boiler on or off. 3. Central Heating program button. Switching the Central Heating on or off (Led on/off); 4. Hot Water program button. Switching the Domestic Hot Water (DHW) facility on or off (Led on/off); 5. Pump program button. When the pump program LED is ON, the pump is switched into a continuous circulation mode. When the pump mode is switched OFF, LED is off the pump is control by the boiler processor. In most situations it is best to leave the pump mode OFF and let the boiler control cycle the pump as needed. During freezing temperatures it is possible (when there is no outside sensor connected), to manually place the circulation pump in constant circulation mode, thus reducing the chance of freezing pipes (garage, attic or other cold spaces / rooms) which are sensitive to frost. Operating instructions Rinnai Q-Series !! 6 Mode-button. Only for Service personel 7 Step-button. After briefly pressing, the water pressure can be retrieved. After pressing for 5 seconds it switches from the Good-state to technical read out and vice versa (see following pages); 8 Reset-button. When a fault occurs it will be shown by the flashing E (Error) with a number code after which the boiler is shut down. After pressing the reset key you can try to start the boiler again. If the error message keeps occurring co...

Este manual também é adequado para os modelos :
Aquecedores de Água - Q130SP (957.68 kb)
Aquecedores de Água - Q130SN (957.68 kb)
Aquecedores de Água - Q175CN (957.68 kb)
Aquecedores de Água - Q175CP (957.68 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias