Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Bock s, Modelo 51PP

Fabricante : Bock s
Arquivo Tamanho: 180.73 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Reset the primary control. If the motor still does not run, replace the control. 5. If the burner ignites and runs a short time (30-40 seconds), then goes out on safety, replace the flame detector. If the burner still runs only a short time, replace the control. 6. If there is a smell of oil or combustion products, remove and clean the electrode assembly (see No. 2 above). Check the draft in the stack above the heater. Stack draft (pull in) should be -.02” W.C. minimum to -.05” W.C. maximum. Check for exhaust fans in the heater room or adjacent areas which draw combustion air away from heater. THE HEATER MUST HAVE COMBUSTION AIR TO OPERATE. For more information, contact your installer, the nearest Bock distributor, or write, call or fax: BOCK WATER HEATERS, INC. 110 South Dickinson Street, Madison, WI 53703 Phone: 608/257-2225 • Fax: 608/257-5304 –7– FIGURE 6:Beckett or Wayne burner w/ Carlin EZ-Temp For Models: 32, 33, 40, 50, 51, 71, 120E FIGURE 7: Honeywell L4103A-1142 For Models: 32, 33, 40, 51, 71E FIGURE 7 NOTES: Set point 120° – 8 – WIRING FIGURE 5: Carlin burner w/ Carlin EZ-Temp For Models: 32, 33, 40, 50, 51, 71, 120E (see burner manufacturer’s instructions for 20e; 60200 primary w/ three wire harness) FIGURE 8:Honeywell L4006Aw/ L8080B For Models: 50, 120E FIGURE 4 NOTES: L4080B L4006A High limit: 190° Aquastat: 120° set point 15° differential – 9 – ITEM DESCRIPTION 1. Cold Water Inlet Dip Tube (N/A 33E & 40E) 2. Plastic Cap 3. Magnesium Anode Rod (aluminum avaliable) 4. Name Plate/Rating Label 6. Immersion Well & Aquastat 8. Drain Valve 9. Mounting Bracket Gasket 10. Burner Mounting Bracket (part of jacket assembly on Models 20e, 32E through 51 Series; sold separately on 71E and 120E) 11. Bottom Pan 12. Combustion Chamber Sleeve 13. Combustion Chamber 14. Inspection Block 15. Inspection Door 16. Inspection Door Gasket 17. Heater Jacket 18. Tank 19. Hot Out Nipple 51 Series: 1” AlI others: 3/4” 50ES: N/A 20. Top Pan 21. Burner 22. Primary Relay 23. Cad Cell ITEM DESCRIPTION 1. Motor 2. Blower Wheel 3. Burner Housing 4. Motor Cord Cover 5. J-Box 6. Transformer 7. Housing Cover 8. Slot Cover Plate 9. Inner Air Band 10. Outer Air Band 11. Coupling (not shown) BURNER COMPONENTS LIST BURNER COMPONENTS ITEM DESCRIPTION 12. Oil Line Assembly 13. Fuel Unit 14. Elbow 15. Gun Assembly 16. Air Tube 17. Flange 18. Air Cone 19. Gasket 20. Nozzle (not shown) 21. Relay 22. Cad Cell OIL FIRED WATER HEATER BOCK TANK ASSEMBLY PARTS LIST When ordering repair parts, always give the part name, model number, size and serial number. Handhole cover plate and gasket (for 50ES only) not shown. – 9 – ITEM DESCRIPTION 1. Cold Water Inlet Dip Tube (N/A 33E & 40E) 2. Plastic Cap 3. Magnesium Anode Rod (aluminum avaliable) 4. Name Plate/Rating Label 6. Immersion Well & Aquastat 8. Drain Valve 9. Mounting Bracket Gasket 10. Burner Mounting Bracket (part of jacket assembly on Models 20e, 32E through 51 Series; sold separately on 71E and 120E) 11. Bottom Pan 12. Combus...

Este manual também é adequado para os modelos :
Aquecedores de Água - 33E (180.73 kb)
Aquecedores de Água - 33PP (180.73 kb)
Aquecedores de Água - 40E (180.73 kb)
Aquecedores de Água - 40PP (180.73 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias