Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Haier, Modelo QBJ1-200A58E

Fabricante : Haier
Arquivo Tamanho: 524.12 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Any alteration to the structure of the solar water heater may cause the trouble while using it. 2. There are 5 connection methods of the water pipe into the room, they are smoke way, vent-pipe hole on the wall appropriative solar well prepared cannula and the first three kinds are common. Before the installation, our professional will consult the room's situation and choose the suitable location to bring you convenience. A upend slope is necessary ,and should be wind-tight to prevent the rainy water or smell's entrance. 3. Keep the placket of the overflow pipe downwards and fasten it so that the liquid can be lead to the cloaca directly, and please notice that the distance of the overflow pipe and the cloaca should less than 15cm. Don't placed the pipe optionally, so can avoid the water spatter. 4. Don't install the valve in the pipeline to insure that the signal which shows the water is overflow will be worked normally. 5.To avoid the water in the tank flow inverted, an unilateralism valve should be installed at the joint of the water pipe and the tap water. 6. The installation project should be confirmed by our professional service personnel when install several sets of these series. Contact to the water tank Please install another one- directional valve at the cold and hot water pipes if the solar tank is connected with other kinds of tanks to avoid the exceed pressure in these tanks flowing backwards to the solar tank and lead accidents. Other water heaters Tap water Hot water Illustration of connect the solar tank with other tanks 8 Assembly InstructionAssembly Instruction Pipelines thermal insulation notice 1.Outdoor pipelines should be thermal insulated according to local climate, bad thermal insulation may lead to heat loss. 2.The outlet used by electric tracing belt must ground reliably. The rated current of outlet is less than 10A, ensure is connected to plug reliably. 3.Fixing electric tracing belt on cold and hot water pipes, in order to touch well, it should be fixed with insulating tape per 500 mm. 4.Waterproof should be tied up on thermal insulating pipes, for example aluminum foil cloth, glass fibre cloth, ethylene polyester waterproof film etc. Note: in cold area, electric tracing belt should be fixed on outdoor pipelines. Otherwise when the environmental temperature is lower than -5 , any innocent thermal insulation will lead to the pipelines frozen, resulting in the pipelines damage. The product with controller installation and using notice 1.If you fix controller, please select Haier products, otherwise our company won't be responsible for personal injure and damage of water heater. 2.Haier has the controller used in domestic water heater, which has cord and plug, and they are connected well. Please select the electrical outlet of good quality, its rated current is not less than 16 A, and must ground reliably. 3.The cord of controller mustn't be layed in thermal insulating layer of pipelines, should be layed out of thermal ins...

Este manual também é adequado para os modelos :
Aquecedores de Água - QBJ1-130A58E (524.12 kb)
Aquecedores de Água - QBJ1-150A58E (524.12 kb)
Aquecedores de Água - QBJ1-175A58E (524.12 kb)
Aquecedores de Água - QBJ1-230A58E (524.12 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias