Any form of modification of the installation structure of the water heater may cause problems in use. 2. There are 5 ways for the heater pipeline to enter the house: flue, exhaust pipe, penetrating hole, special pipeline well for solar water heater, embedded bushing. Of which the first 3 are relatively popular. Before installing the pipeline, the installation personnel will discuss the entering way and installation position of the pipeline with you for your convenient use. During piping, the penetrating hole must have an adverse slope and be sealed properly to prevent rain and odor from coming into the house. 3. The overflow pipe must be fastened firmly and its indoor opening must be kept downward. The overflow water can be discharged directly into the sewer. The distance between the opening of the overflow pipe and the sewer plane should not be more than 15cm. Never hang the overflow pipe arbitrarily as splash of large amount of overflow water will damage articles in your house. 4. Never install valve in the overflow pipeline to ensure rapid, accurate transfer of Full-of-Water signal. 5. Check valves should be installed on the trunks of water supply and drain pipes that are connected with the tap water pipe to prevent back flowing of water in the tank. 6. When several water heaters are combined, the installation plan should be validated by a professional service person of Haier. Installation instructions · Operation instructions • Connection method of water supply pipeline in the houses where a solar water heat coexists with another type of water heater To the tank of the solar water heater Another type ofWhen a solar water heat coexists water heater with another type of water heater, check valves must be installed on both cold and hot water pipes to avoid damage caused by reverse water flow from tank of another Tap water heater, which has higher pressure, to that of the solar heater. Solar water heater • Operation methods: 1. Before using hot water, valves K1, K2 and K3 must be in closed state; 2. To fill water, open valve K1. When water flows out from the overflow pipe, it indicates the water tank is full. At this time, close valve K1. 3. To use hot water, open valve K2. Hot water will come out from the shower nozzle. If it is too hot, open valve K3 to adjust the water temperature. 4. Close valves K2 and K3 after use. Vent Overflow Water inlet and outlet Tap water Check valve Operation instructions • FAQ Troubles Possible reasons Solutions No outlet water The water tank becomes empty Add water according to the time required in the instruction manual Disconnection or blockage of the pipeline or joints Repair the pipeline or remove the blockage No water comes from the overflow Broken vacuum tube(s) Replace the broken tube(s) pipe Water supply is stopped or water pressure is too low Wait until the water supply becomes normal Disconnection or break of the pipeline or joints Repair or replace the pipeline or joints Too low temperature of the hot wa...
Este manual também é adequado para os modelos :Aquecedores de Água - S110ENF (189.25 kb)
Aquecedores de Água - S110ENL (189.25 kb)
Aquecedores de Água - S85ENL (189.25 kb)
Aquecedores de Água - S125ENF (189.25 kb)