Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação Bosch, Modelo AQUA STAR 2400E NG

Fabricante : Bosch
Arquivo Tamanho: 2.87 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Warning: This heater must be electrically grounded in accordance with the most recent edition of the National Electrical Code NFPA 70. In Canada, all electrical wiring to the heater should be in accordance with local codes and the Canadian Electrical Code, CSA C22.1 Part 1. Do not rely on the gas or water piping to ground the metal parts of the heater. The 2400 E requires an electrical power supply from a 120VAC / 60Hz circuit (with a dedicated outlet) and must be properly grounded. A means for switching off the 120VAC power supply must be provided. The heater is wired as shown in the wiring diagram (chapter 7, Fig. 44). 3.11 Cascading function Cascading enables the appliance to be connected in parallel with up to 4 appliances. An appliance in this system will only start, if it gets a signal from the appliance before it. That means, the appliance works always as a Master to the next appliance and always as a Slave to the one before. For more detailed information about this feature, consult the instructions supplied with the accessory: • 7 709 003 617. 3.12 Recirculation application Since recirculation through the heater is not permissible, the following drawing is provided to outline a proper recirculation application using the Aquastar water heater with an Ariston minitank water heater. This schematic is for illustration only and must not be used for actual installation without appropriate engineering and technical advice from a properly licensed professional in the locality where the installation is made. 2400 E Ariston Minitank Fig. 27 Recirculation application 1 Full port isolation valve 2 Circulator 3 Check valve 4 PRV 5 Expansion tank The use of a small electric mini-tank water heater (4-6 gallon size) should be used for this application and designed so the pump will circulate the water through the mini-tank and the building's hot water return loop only. Timed or thermostatically controlled operation of the pump is commonly done. The 2400 E must be supplied with cold water only and plumbed in line before the mini-tank water heater. Contact Bosch Water Heating if further information is needed. 6 720 608 263 Operation instructions Operation instructions Fig. 28 1 On/Off switch 2 Reset button 3 Program “ “ button 4 Increasing temperature selector 5 Decreasing temperature selector 6 LCD display 4.1 For your safety, read before operating your water heater Warning: The front cover of this appliance must be secured and properly sealed at all times once vent pipe and water connections are made. Failure to do so may result in freezing (not covered under warranty), improper fuel air mixture or error code faults. Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with electronic ignition for lighting the main burners. When turning the heater on, follow these instructions exactly. B. Before operating the unit, set the On/Off switch to the On ( I ) position. WHAT TO DO IF YOU SMELL GAS B Do not try to light any appliance. B Do not touch any electric switch; do not use any phone in your building. B Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions. B If you cannot reach your gas supplier, call the fire department. C. Use only your hand to turn the on/off control switch. Never use tools. Follow these instructions exactly. If control switch is jammed, close the gas supply and call Bosch Technical Support. Attempted forceful repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 4.2 Power On B To start the appliance move the on/off switch to the "on" position (I). LCD will display the default temperature factory setting 122°F (50°C). Fig. 29 6 720 608 263 Operation instructions Off B To shut down the appliance move the on/off switch to the “off” position (0). 4.3 Temperature selection To select output water temperature: B Press buttons and in order to reach desired temperature. Fig. 30 If the outlet water temperature is set too high, the heater can produce temperatures that are too hot. A temperature balance shower valve will automatically mix in cold water to reduce such hot water temperature. In the event of any temperature fluctuation with the use of a temperature balance shower valve, refer to shower valve manufacturer's instructions for internal adjustment setting. Adjustments should be made to the hottest setting in the shower valve. Additionally the temperature control of the heater can be lowered to produce a more comfortable hot water temperature. 6 720 608 263 Operation instructions Setting the water temperature The desired temperature of the hot water can be adjusted on the front control panel of the heater. The 2400 E has ...

Este manual também é adequado para os modelos :
Aquecedores de Água - AQUA STAR 2400E LP (2.87 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias