Facilidade de uso
Boiler Clearances *F90 & F140 300 if no rear flue. Option Kits Boiler plus II Outside sensor kit * Hours run meter(s) * Tank sensor kit . BMS (0-10V) kit * Remote indication kit * *Provided as standard 6 xtra 80 - 560kW • Robust cast aluminium heat exchanger • In-built commissioning and fault diagnostics • Low NOx emissions • Volt free contacts supplied as standard • Meets Building Regulations 2006 (Part L2) • Compact size - small footprint • Fully modulating operation down to 20% of output • Up to 107.5% nett efficiency (fully condensing) • Fits through standard doorways ExtendedOutputRange General Data xtra(80 - 560) Model 80 120 160 200 240 280 320 400 480 560 Boiler output (condensing) 25.6 -25.6 -32.0 -47.1 -51.4 -55.6 -75.3 -107.5 -116.1 -118.3 - 50/30°C 82.2 123.4 164.5 207.8 249.4 290.9 329.0 415.6 498.8 581.8 Boiler output (non-condensing) 23.3 -23.2 -29.0 -43.1 -47.0 -51.0 -67.8 -97.7 -105.5 -107.7 - 80/60°C 77.4 116.0 154.8 195.4 234.5 273.6 311.6 390.8 469.0 547.2 Height 1150 Width 600 600 600 600 600 600 1200 1200 1200 1200 Depth 1024 1024 1024 1327 1327 1327 1004 1326 1326 1326 Flow connection (BSP) R2” R2” R2” R2” R2” R2” 80* 80* 80* 80* Return connection (BSP) R2” R2” R2” R2” R2” R2” 80* 80* 80* 80* Gas inlet connection (BSP) R1” R1” R1” R1” R1” R1” R2* R2* R2* R2* Nominal flue size / concentric (mm) 150 150 150 200 200 200 200 250 250 250 Maximum working pressure (bar) 6 Water content (L) 11.0 14.3 17.5 18.4 24.0 27.2 35.0 36.8 48.0 54.4 Weight (kg) 132 150 168 198 215 233 336 396 430 466 Front (mm) 600 Back (mm) 700 700 700 700 700 700 1000 1000 1000 1000 Side (mm) 450 150 450 150 450 150 450 150 450 150 450 150 450 450 450 450 (LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH) *DN flange. Flow, return and gas connection sizes shown are for the optional header kit. If header kit not used: Flow & Return connections are 2 x R2. Gas connection is 2 x R1. Boiler Clearances Option Kits Boiler xtra Boiler xtra 80 - 280 320 - 560 80 - 280 320 - 560 Modulating sequence control for .. Outside sensor kit .. controlling multiple boiler installations Room sensor kit .. Programmable room thermostat .. Sequencer DHW sensor kit .. Tank sensor kit . n/a Control interface kit . Standard BMS control kit (0-10V) . Standard condensing Concord CXC 48 - 116kW • Natural gas fired condensing boiler • Meets Building Regulations 2006 (Part L2) • Fully condensing high efficiency 85% at 80°C, 93% at 60°C flow • Compact space saving design • Full automatic ignition • Advanced electronic controls Model 48 70 94 116 Boiler output (condensing) 48.83 69.84 93.65 116.25 50/30°C Boiler output (non-condensing) 44.63 63.84 83.60 106.30 80/60°C Height 1438 Width 600 Depth 723 846 969 1092 Flow/Return Connections (BSP) RC2 Gas Inlet (BSP) RC3/4 RC3/4 RC3/4 RC1 Flue Size (mm) 150 Maximum Working Pressure (bar) 4.5 Water Content (L) 28 36 43 51 Approx Dry Weight (kg) 298 350 442 494 Front (mm) 750 Back (mm) 200 Side (mm) 50 50 50 100 General Data Concord CXC (48 - 116) Boiler Clearances Option Kits Boiler Concord CXC Remote indication board . Outside sensor . 8 GT Condenser 199 - 1096kW • Up to 16% extra heat • Compact space saving design • Adjustable flue and system connections • Low flue and system resistances • High insulation levels • Fanned or standard versions • Suitable for Harrier, Viceroy and Viscount boilers Model RCI 300 RCI 300V RCI 400 RCI 400V RCI 500 RCI 500V Output (kW) 180 - 450 230 - 670 390 - 986 Height (mm) 1687 1777 1883 Width (mm) 610 698 830 Depth (mm) (over optional fan) 1156 1250 1376 Flue Size (mm) 300 350 400 General Data GT Condenser (199 - 1096) The addition of a GT Condenser to the boiler can provide up to 16% more heat by cooling the flue gases to gain both sensible and latent heat from condensation. The lower the system return temperature being fed into the Condenser the more the gain. It all provides benefits in lower emissions and lower fuel bills. This GT Condenser range is suitable for gas fired boilers only but can be fitted to dual fuel boilers with suitable flue design. Six models are available to suit Option Kits Boiler GT Condenser Fan version RCI 300V RCI 400V RCI 500V Harrier, Viceroy and Viscount boilers with a boiler output range suitability from 180kW (614,000 Btu/h) to 986kW (3,364,000Btu/h). Three output models cover this range and to ensure easy flue installation, each is available with or without a fan to overcome the flue pressure loss of the GT Condenser if necessary. A 6 bar working pressure capability ensures system application is straight forward. gas atmospheric Concord CXA/H S/H 40 - 120kW • Ul...
Este manual também é adequado para os modelos :Aquecedores de Água - F270 (1.05 mb)
Aquecedores de Água - F140 (1.05 mb)
Aquecedores de Água - F180 (1.05 mb)
Aquecedores de Água - F220 (1.05 mb)