|
Facilidade de uso
To increase the room temperature, press the top arrow of the TEMP button. To lower room the temperature, press the bottom arrow to the TEMP button. At higher settings the heater will run more. IMPORTANT:The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off. 3. Use the STATUS button on the handheld remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the operation mode being used when the status button is pressed. 4. To turn the burners off when operating in the MANUAL mode, press the OFF button. If operating in the auto mode, press the manual button, then press the OFF button The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position or set remote selector switch to OFF position. Flame Adjustment Knob Control Knob in On Position ON OFF REMOTE OFF PILOT ON LO IH Remote Selector Switch in Remote Position Figure 28 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation 16 104307 OWNER’S MANUAL OPERATING HEATER Continued Shows Temperature Setting HI Increases RooTemperature m Allows Burners to be Turned On and Off with the Hand- Held Remote Unit. MAN LO TEMP ON Decreases Room Temperature Turns Burners The log heater will automatically cycle between pilot and the heat setting that has been selected. AUTO STATUS OFF On and Off Shows Current Operation Mode Figure 29 - Thermostat Hand-Held Remote Control Unit Selections INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 30 shows a correct pilot flame pattern. Figure 31 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down. Thermocouple Pilot Burner Figure 30 - Correct Pilot Flame Pattern If pilot flame pattern is incorrect, as shown in Figure 31 • turn heater off (see To Turn Off Gas to Appliance, page 16) • see Troubleshooting, pages 18 through 20 MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot. Pilot Burner Thermocouple Figure 31 - Incorrect Pilot Flame Pattern CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, etc. ODS/PILOT AND BURNER • Use a vacuum cleaner or small, soft bristled brush to clean. LOGS • If you remove logs for cleaning, refer to Installing Logs, pages 13 and 14, to properly replace logs. • Replace log(s) if broken or chipped (dime-sized or larger). BURNER PRIMARY AIR HOLE Air is drawn into the burner through the 8 holes in the brass fitting at the burner entrance. There holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot. MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot. 104307 17 CGD3924PR, CGB3924PR and CGB3930PR UNVENTED PROPANE/LP GAS LOG HEATER TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, there is no spark at ODS/pilot 1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet 3. Piezo ignitor nut is loose 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong 1. Reconnect ignitor cable 2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located ...
Este manual também é adequado para os modelos :Aquecedores de Água - CGB3924PR (941.72 kb)
Aquecedores de Água - CGB3930PR (941.72 kb)