Instruções de Operação Lochinvar, Modelo CREST 1.5

Fabricante : Lochinvar
Arquivo Tamanho: 2.49 mb
Arquivo Nome : 04b74426-feaa-4b92-8da4-5bb4f345f859.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Otherwise, set the ModBus parameter to INACTIVE. Note that the boiler can still be monitored by ModBus with this parameter set to INACTIVE. ModBus Out of Order Timer When the boiler is being provided with certain commands and temperatures through ModBus, this information must be updated frequently. If it is not updated before this timer expires, the boiler will revert back to its own internal readings and control. This parameter is adjustable by the installer by accessing parameter I2. J: Cascade Cascade Active / Inactive The boiler is part of a group of units sequenced together. The designated Leader unit determines the total output needed from the group based on the set point and controlling sensor reading. It assigns portions of the output to itself (Leader) and the Member units. When Cascade is active, each boiler in the group requires a unique address. This setting is adjustable by the installer by accessing parameter J1. Cascade Address The boiler designated as the Leader needs to be programmed with address 0. All the Member boilers require addresses from 1 to 7, and the addresses must be different for each Member. The addresses can be in any order, regardless of the order in which the units are wired together. This parameter is adjustable by the installer by accessing parameter J2. The outdoor air (if used) and system supply sensor must be connected to the Leader boiler. Cascade Offset This parameter determines how much the temperature can go above set point before the lead boiler will turn off. This parameter can be adjusted by the installer by accessing parameter J3. Cascade Off-On Differential This parameter determines how much the temperature must go below the turn off temperature (Set point + Offset) before the lead boiler turns on. This parameter can be adjusted by the installer by accessing parameter J4. Maximum Boiler Set Point for Cascade This parameter determines the set point used by the individual boilers in a Cascade. When a boiler is commanded to fire by the Leader boiler, it will attempt to achieve this temperature at its outlet. If any of the boiler outlet temperatures reach the maximum cascade set point, the boiler will then modulate down on its own in order to keep its outlet temperature within the maximum cascade set point. Therefore, this parameter can be used to limit the outlet temperatures of all the boilers in a Cascade. Note that this parameter does not apply when the boiler is heating an indirect HWG tank. This parameter is adjustable by the installer by accessing parameter J5. Cascade Type The Cascade divider method is Efficiency Optimization, designated as EFF in the menu. This method is used, as the name implies, when it is desired to have the most efficient system. When the first boiler reaches a certain rate (default = 80%), it lowers its rate to 40% and turns on the next boiler at 40%. The two (2) boilers then modulate at the same rate. As the calculated load increases further and both boilers ramp up to 80%, it lowers the rate of the first two (2) boilers to 53% and brings the next boiler on at 53%. The three (3) boilers then modulate together. As the calculated load decreases, the boilers will reach a lower threshold (default = 10%), at which time the last boiler (the third in our example) will turn off and the Cascade will increase the rates of the remaining boilers to provide the equivalent total output as before ((3 x 10%) / 2 = 15% in our example). This parameter can be adjusted by the installer by accessing parameter J6. Minimum On/Off Time In order to prevent units in a Cascade from short cycling, this parameter defines the minimum ON and OFF time for each unit. The installer can adjust this time by accessing parameter J7. 23 Service Manual 1 11 Service ServiceService Minimum Next On Time In order to reduce the risk of temperature overshoot with a Cascade, this parameter defines the minimum time delay from starting one unit until the next unit may be started. The installer can adjust this time delay by accessing parameter J8. Rate % to Switch on Next Boiler When the Cascade is programmed in the Efficiency Optimization Mode, the currently running boilers must ramp up to a certain firing rate before the next boiler in the Cascade will start. This percentage can be adjusted by accessing parameter J9. Rate % to Switch off Last Boiler When the Cascade is programmed in the Efficiency Optimization Mode, the currently running boiler will stop. This percentage can be adjusted by accessing parameter J10. Number of Boiler Pumps Always On When multiple Crest boilers are connected in a Cascade, the SMART TOUCH control can keep a minimum number of the boiler pumps running, regardless of how many of the boilers are firing. This is useful in full flow systems where the system flow is provided by the individual boiler pumps. This number can be adjusted by accessing parameter J11. K: Pumps Boiler Pump Delay The SH pump delay parameter sets the length of time the boiler pump will...

Este manual também é adequado para os modelos :
Aquecedores de Água - CREST 2 (2.49 mb)
Aquecedores de Água - CREST 2.5 (2.49 mb)
Aquecedores de Água - CREST 3 (2.49 mb)
Aquecedores de Água - CREST 3.5 (2.49 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias