Fabricante : Bosch
Arquivo Tamanho: 103.02 kb
Arquivo Nome : 86e77786-1337-416c-affc-3c513ee94009.pdf
|
Facilidade de uso
Failure to install the appliance correctly could lead to prosecution. The manufacturers notes must not be taken, in any way, as overriding statutory obligations. IMPORTANT: Read these instructions carefully in order to get the best from your appliance. WARNING: This appliance must be earthed and protected by a 3A fuse if a 13A plug is used, or, if any other type of plug is used, by a 5A fuse either in the plug or adaptor or at the distribution board. PROGRAMMER 5 day/2 day (simple setting) or multiday (full function setting) twin channel digital programmer. The HW and CH channels can be set independently. Integral lithium battery provides 5 year back up in case of mains failure. TO FIT THE PROGRAMMER Before starting work, turn off the mains electricity supply to the appliance. Remove the front panel from the appliance by sliding it upwards to clear the locating pegs and securing clips. Remove the three screws securing the bottom panel to the fascia. Remove the two screws securing the fascia assembly to the appliance and lower it forwards to the servicing position. Remove the programmer blanking plate from the front of the fascia by carefully releasing the clips at the rear right-hand side and withdrawing the plate from the front. Feed the electrical lead from the programmer through the fascia to exit directly underneath it and fit the programmer by hooking the top two lugs up into the facia slots and then push the bottom two clips until they snap into position. From the rear of the fascia, remove the plastic splash cover to reveal the electrical connection box and remove the two screws securing the cover to the box. Secure the cable from the programmer using the clamping positions on the underside of the fascia and the rear of the electrical connection box and plug the cable into the corresponding five-way socket on the rear of the fascia. Clamp cable here Connect plug from timeswitch here Fig. 1. Replace the electrical box cover, splash cover and fascia bottom panel, and secure the fascia using the two screws and refit the front panel. 1 PROGRAMMER OPERATING INSTRUCTIONS TO SET PRESENT TIME AND DAY Set right switch to RUN. Press HR & MIN buttons together (until colon stops flashing) After 15 seconds the colon will start flashing again signifying the settings cannot be changed. Repeat this step if you still want to set time and day. Press DAY button until arrow points to correct day. Press HR and MIN buttons separately until correct time is displayed. Set right switch to DHW then back to RUN (or leave for 15 seconds) to start the clock. M T W Th F S Su P DAY HR MIN ADV Reset I AUTO O RUN DHW CH Set 8:37 Normal run mode Set DHW programme Set CH programme Channel 1 (DHW) Channel 2 (CH) Demand symbol (light bulb) Advanced symbol Programmer step number Advance button Set time orSet time orSet actual or Step through programme Actual time or set time Monday to Sunday Permanent on Timed programme Permanent off 1 2 3 Fig. 2. programme day programme hours programme minutes TO SET PROGRAMME TIMES This programmer provides eight switch periods per channel, with a day selection of Mon...Fri, Mon...Sat, Sat/sun, all days together or all days individually. If it is considered confusing to programme all variations, the following describes two levels of setting the programme; simple or full-function; SIMPLE PROGRAMME SETTING The programmer has an in-built programme of ‘standard’ switching times shown in the table. These may be changed to suit your specific requirements. PROGRAMME STEP STANDARD PROGRAMME DHW MON-FRI CH MON-FRI 1 6.30am 6.30am 2 8.30am 8.30am 3 4.30pm 4.30pm 4 10.30pm 10.30pm SAT-SUN SAT-SUN 5 7.00am 7.00am 6 9.00am 9.00am 7 4.00pm 4.00pm 8 11.00pm 11.00pm 2 Set right switch to DHW. The display shows weekdays Mon...Fri and the first standard on-time (programme step 1) Press HR & MIN buttons for your required first on time for the week. Press P Display shows the first standard off-time (programme step 2) Press HR & MIN buttons for your required off time. Use buttons P HR and MIN as above for next weekday switch period, then the two weekend periods, finishing with programme step 8. Odd programme step numbers are on times and even numbers are off times. Set right switch to CH and repeat above for all central heating programmes. Set right switch to RUN. NOTE: The standard programme also contains further programme steps 9-16. These should be ‘switched off’ ie the display sh...
Este manual também é adequado para os modelos :Aquecedores de Água - 24SBI (103.02 kb)