Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Everpure, Modelo 625.34855

Fabricante : Everpure
Arquivo Tamanho: 1.36 mb
Arquivo Nome : b25138f2-b8f8-480a-8c08-53aa39771915.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


BE SURE THE FLOW PLUG WITH THE LARGEST CENTER HOLE IS LOCATED IN THE NOZZLE & VENTURI HOUSING. other equipment is needed. Your local Sears store has trained people to help you with iron water problems. If your water supply has clear water iron, even though less than the maximum allowed, regular resin bed cleaning is needed. Sears has resin bed cleaner, Stock No. 42-34426 for this. Clean the bed at least every 6 months. If iron shows up in the soft water before 6 months, clean more often. Printed instructions are on the resin bed cleaner bottle. 16 SECTION 3 CARE OF YOUR SOFTENER 3C. KEEP THE SOFTENER FROM FREEZING If the softener is installed where it could freeze 11[_ ill DRAIN WATER FROM THE (summer cabin, lake home, etc.), you must drain SOFTENER all water from it to stop possible freeze damage. To drain the softener 1. Close the shut-off valve on the house main water pipe, near the water meter or pressure tank. 2. Open a faucet in the soft water pipes to vent pressure in the softener. e Refer to FIG. 12 on page 19. Move the stem in Drain Wood Block a single bypass valve to bypass. Close the inlet and outlet valve in a 3-valve bypass o system, and open the bypass valve. If you Looking at FIG. 11, lay a piece of 2 inch thick want water in the house pipes again, reopen board near the floor drain. Move the softener close to the drain. SLOWLY and CAREFUL- the shut-off valve on the main water pipe. LY tip it over until the rim rests on the wood 4. Unplug the transformer at the wall outlet. block with the inlet and outlet over the drain. Remove the salt hole cover and the main Do not allow the softener _ weight to rest on cover. Take off both drain hoses. the inlet and outlet fittings or they will break. e Carefully remove the large holding clips at e the softener inlet and outlet (see Key No. 61, Tip the bottom of the softener up a few inches on page 30). Separate the softener from the and hold until all water has drained. Leave adaptors or bypass valve. the softener laying like this until you are ready to use it. Plug the inlet and outlet with Go Remove the brinewell cover and disconnect rags to keep dirt, bugs, etc. out. the brine valve tubing at the nozzle and venturi assembly (see page 30). Lift the brine valve out of the brinewell. Tip the brine valve upside down to drain out water. 17 SECTION 3 CARE OF YOUR SOFTENER 3D. HELPFUL HINTS CHECKLIST ... TO HELP YOU SAVE MONEY If your water softener fails to work, make the following easy checks. Often, you will find what's wrong yourself and you won't have to call and wait for service. If, after making the checks, your softener still does not work right, call your Sears Service Department. NOTE: 1. Also read ERROR CODE, page 11. 2. If an error code is not dispIayed, press and holdthe #1 SELECT button until (example: 000--) shows in the display. Then, press the #1 SELECT again and hold until a flashing AR code appears. It must show AR31. If AR 17, 22, 39 or 60 shows, the face plate computer is working on incorrect input and would probably be the cause of the problem. To set AR31, press either the UP [] or DOWN {_)utton. When AR31 shows, press the # 1SELECT to return a flashing 12:00 AM display. Reset the present time, hardness number and recharge time, pages 6 and 7. PROBLEM CAUSE CORRECTION NO SOFT WATER No salt (or salt bridged ) in the storage tank Refill with salt, or break the salt bridge (page 15). Press ON/OFF-HOLD (RECHARGE NOW) button and hold for 3 seconds to start a regeneration (see page 10). Transfomer unplugged at the wall outlet, or Check for loss of power due to any of power cable leads loose, fuse blown, circuit these and correct. With the power back breaker popped, or circuit switched off. on, look at the time display and read PROGRAM MEMORY, page 11. Manual bypass valve(s) in bypass position Look at FIG. 12 on page 19. Move the stem in a single valve to service. In a 3-valve bypass, open the inlet and outlet valves, and be sure to fully close the bypass valve. Dirty, plugged or damaged nozzle & venturi Take apart and clean or replace damaged parts (see page 16). Valve drain hose plugged The drain hose must not have kinks, sharp bends, or be raised too high above the softener (see page 16 in your installation manual). Press and release the SELECT button SOMETIMES WATER HARD Hardness number setting too low until HARDNESS shows in the display. Read the hardness number in the display and be sure the same grains per gallon number is shown on your water analysis report. See page 7 to reset. Press and release the SELECT button until the present time shows in the display. Using hot water when softener is Avoid using hot water during this time regenerating because the water heater refills with hard water (see Automatic Bypass, page 14). Increase in the grains of hardness in your Ask your Sears retail or catalog store for a water supply new water analysis. Then make a new hardness number setting (page 7). 18 SECTION 4 OTHER THINGS TO KNOW 4A. DIMENSION...

Este manual também é adequado para os modelos :
Purificadores de água - 625.34854 (1.36 mb)
Purificadores de água - 625.34854 (1.36 mb)
Purificadores de água - 625.34855 (1.36 mb)
Purificadores de água - 625.34854 (1.36 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias