Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Everpure, Modelo CES-2750M-101

Fabricante : Everpure
Arquivo Tamanho: 471.06 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


s controlled upflow backwash, downflow brining and slow rinse, rapid rinse, timed brine refill and downflow service Advanced user-friendly controls incorporates time-tested hydraulically balanced piston, seal and spacer design to pilot service flow and regeneration Large capacity brine tank maximizes time between refills Fiberglass reinforced resin vessels with NSF approved polyethylene liners eliminate worries about corrosion Meter initiated regeneration minimizes salt, water, and electrical costs Locate equipment on a smooth, level surface Maintain an air-gap at the end of the drain line Secure drain line directly over floor drain orstand pipe When connecting to a water heater, install acheck valve on the soft water piping to preventhot water back-up When sweating/installing copper piping, protect the control valve from excessive heat Check local codes for additional equipmentthat may be required, such as backflowprevention devices (i.e., RPZ) Check for softened water each time salt is added, by using a soap or hardness test kit Use a good quality grade of salt -Solaror pellet are preferred Check the salt level on a regular basis Maintain at minimum salt depth of 6” toensure a proper regeneration On iron bearing waters, use a salt thatcontains an iron “fighting” additive, or usea resin cleaner on a regular basis Check the water level in the brine tank If abnormally high - refer to IO guide fortroubleshooting information Warewashing Laundry - Linen & Uniform Boiler Scale Control Water Heater Scale Protection/Reduction General Housekeeping CES-2750M-34: EV9982-21 CES-2750M-51: EV9982-22 CES-2750M-68: EV9982-23 CES-2750M-101: EV9982-24 C E S 275 0 S eri es W a t e r C o n d i t i o n e r BENEFITSAPPLICATION/SIZINGINSTALLATIONTIPSOPERATIONTIPSWater Conditioning for Commercial and Light Industrial Applications Available in Single Tank System with 1” Porting Hardness removal of 34,000 to 101,000 grains at flow rates up to 20 gallons per minute continuous Single tank design for simplicity, economy and space savings Fully adjustable 5-cycle control delivers controlled upflow backwash, downflow brining and slow rinse, rapid rinse, timed brine refill and downflow service Advanced user-friendly controls incorporates time-tested hydraulically balanced piston, seal and spacer design to pilot service flow and regeneration Large capacity brine tank maximizes time between refills Fiberglass reinforced resin vessels with NSF approved polyethylene liners eliminate worries about corrosion Meter initiated regeneration minimizes salt, water, and electrical costs Locate equipment on a smooth, level surface Maintain an air-gap at the end of the drain line Secure drain line directly over floor drain orstand pipe When connecting to a water heater, install acheck valve on the soft water piping to preventhot water back-up When sweating/installing copper piping, protect the control valve from excessive heat Check local codes for additional equipmentthat may be required, such as backflowprevention devices (i.e., RPZ) Check for softened water each time salt is added, by using a soap or hardness test kit Use a good quality grade of salt -Solaror pellet are preferred Check the salt level on a regular basis Maintain at minimum salt depth of 6” toensure a proper regeneration On iron bearing waters, use a salt thatcontains an iron “fighting” additive, or usea resin cleaner on a reg...

Este manual também é adequado para os modelos :
Purificadores de água - CES 2750 Series (471.06 kb)
Purificadores de água - CES-2750M-34 (471.06 kb)
Purificadores de água - CES-2750M-51 (471.06 kb)
Purificadores de água - CES-2750M-68 (471.06 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias