Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Kenmore, Modelo ULTRASOFT 250 625.38827

Fabricante : Kenmore
Arquivo Tamanho: 1.27 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Nozzle & Ventud _ _,/ 1) Turn off the cap from the nozzle and venturi housing. Gasket __ iereen 2) Lift out the screen support and screen, do not lose the large o-ring seal. tered directly over the small 3) Then the nozzle and venturi. Wash and rinse the holes in the nozzle & venturi parts in warm water unti! clean. If needed, use a housing. small brush to remove iron or dirt. Also check and *Flow Plug (HVDC) clean the gasket, flow plugs and screens. Nozzle & Ventud Housing Carefully replace all parts in the correct order. Lubricate the o-ring seal with silicone grease or Vaseline and place in position. Install and tighten the *Install with numbered side up concave cap, by hand only. Do not overtighten and break side down. Be sure the largest flow plug is the cap or housing. located in the nozzle & ventud housing. IRON FROM RESIN BED ter or other equipment is needed. Your local Sears store has trained people to help you with iron water Your water softener takes hardness minerals (cal problems. cium and magnesium) out of the water. It can also control some "clear water" iron. See maximum al lowed in the specifications on page 4-1. With clear If your water supply has clear water iron, even water iron, water from a faucet is clear when first though less than the maximum allowed, regular put into a glass. After 15 to 30 minutes, the water be-resin bed cleaning is needed. Your local Sears store gins to cloud or turn rust colored. A water softener has resin bed cleaner, Item No. 42-34426 for this. WILL NOT remove any iron which makes the water Clean the bed at least every 6 months. If iron shows cloudy or rusty as it comes from the faucet (called up in the soft water before 6 months, clean more red water iron). To take red water iron out of water, often. Printed instructions are on the resin bed or over the maximum of clear water iron, an iron ill-cleaner bottle. 3-2 Problems, Questions? Call 1-800-426-9345 Kenmore Water Line _!!_ii_i!i_ SECTION3 _i_ii_i_i_i_J_i_l CARE OF YOUR WATER SOFTENER C. PROTECT THE WATER SOFTENER FROM FREEZING If the softener is installed where it could freeze Drain All Water From Softener (summer cabin, lake home, etc.), you must drain all water from it to stop possible freeze damage. To drain the softener: []Close the shut-off valve on the house main water pipe, near the water meter or pressure tank. []Open a faucet in the soft water pipes to vent pressure in the softener. I []Refer to FIG. 14 on page 4-1. Move the stem in a single bypass valve to bypass. Close the inlet and outlet valve in a 3-valve bypass system, and drain wood block open the bypass valve. If you want water in the house pipes again, reopen the shut-off valve on the main water pipe. []Unplug the transformer at the wall outlet. Re-[]Looking at FIG. 12, lay a piece of 2 inch thick move the salt hole cover and the main cover. board near the floor drain. Move the softener Take off both drain hoses. close to the drain. SLOWLY and CAREFULLY, tip it over until the rim rests on the wood block _-_ Carefully remove the large holding clips at the with the inlet and outlet over the drain. Do not softener inlet and outlet (see Key No. 67, on page allow the softener's weight to rest on the inlet 6-5). Separate the softener from the copper and outlet fittings or they will break. tubes, or from the bypass valve. []Remove the brinewell cover and disconnect the [ Tip the bottom of the softener up a few inches brine valve tubing at the nozzle and venturi as-and hold until all water has drained. Leave the sembly (see page 3-2). Lift the brine valve out of softener laying like this until you are ready to the brinewell. Tip the brine valve upside down use it. Plug the inlet and outlet with rags to keep to drain water, dirt, bugs, etc. out. 3-3 Problems, Questions? Call 1-800-426-9345 Kenmore Water Line D. CHECKLIST ... TO HELP YOU SAVE MONEY If your water softener fails to work make the following easy checks. Often, you will find what's wrong yourself and you won't have to call and wait for service. If you do not find anything wrong, while making the checks, and your softener still does not work, call your Sears Service Department. Note: 1. Also read ERROR CODE, page 2. If an error code is not displayed, the SELECT button again and hold SR33 for UltraSoft 275. If any other would probably be the cause of the 2-3. press and hold the SELECT button until the display changes. Then, press until a flashing SR code appears. It must show SR29 for UltraSoft 250 or number shows, the face plate computer is working on incorrect input and problem. To set SR29 or SR33, press either the UPI_ or DOWN(_ button. When correct model code shows, press SELECT to return a flashing hardness number, etc., pages 1-3 and 1-4. PROBLEM No soft water Water hard sometimes Brine tank flooded CAUSE No salt (or salt bridged) in the storage t'ank Transformer unplugged at the wall outlet, or power cable leads loose from the electronic board, fuse blown, circuitl breaker popped...

Este manual também é adequado para os modelos :
Purificadores de água - ULTRASOFT 250 625.38826 (1.27 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias