Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação GE, Modelo GXRM10RBL

Fabricante : GE
Arquivo Tamanho: 3.06 mb
Arquivo Nome : e99472f7-476d-43f1-9852-8b3b8962ad03.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


. . . . . . . . . . . . . . . .2 Specification Guidelines . . . . . . . . . . . . .3 Installation Instructions Before Beginning Installation . . . . . . . .4 Faucet Drain Tubing and Water Supply Tubing . . . . . . . . . . . . . . . .8 Faucet Installation . . . . . . . . . . . . . . . . . .7 Filtration Drain Connection . . . . . . . . . .8 System Assembly . . . . . . . . . . . . . . . . . . .9 Things to Check Before Installation . . . . . . . . . . . . . . . . . . .5 Tools and Materials Required . . . . . . . .4 Water Supply . . . . . . . . . . . . . . . . . . . . . . .6 Care and Cleaning Prefilter, Postfilter and RO Cartridge Replacement . . . . .10, 11 Sanitization . . . . . . . . . . . . . . . . . . . . . . . .10 Water Test Kit . . . . . . . . . . . . . . . . . . . . .12 Operating Instructions About the RO System . . . . . . . . . . .13, 14 Troubleshooting Tips . . . . . . . . . .15 Consumer Support Consumer Support . . . . . . . .Back Cover Parts List/Catalog . . . . . . . . . . . . . .16, 17 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .20 C U.S. Owner’s Manual and Installation GXRM10RBL Osmose Inversee Systeme de Filtration Manuel d’utilisation et d’installation La section francaise commence a la page 21 Osmosis Inversa Sistema de Filtracion Manual del propietario y instalacion La seccion en espanol empieza en la pagina 41 GXRM10RBL is Tested and Certified by NSF International against NSF/ANSI Standard 58 and CSA B483.1 for reduction of the claims specified on the Performance Data Sheet. Write the model and serial numbers here: Model # __________________ Serial # __________________ You can find them on the bracket. 215C1219P004 49-50237 07-09 JR IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. Consumer Support Troubleshooting Tips Operating Instructions Safety InstructionsInstallationInstructions WARNING! WARNING! For your safety, the information in this manual must be followed to minimize the risk of property damage or personal injury. SAFETY PRECAUTIONS ¦ Check with your state and local public works department for plumbing and sanitation codes. You must follow these guidelines as you install the Reverse Osmosis system. Using a qualified installer is recommended. ¦ If house water pressure is over the maximum (125 pounds per square inch), install a pressure reducing valve in the water supply line to the Reverse Osmosis system. ¦ Be sure the water supply conforms with the Specification Guidelines. If the water supply conditions are unknown, contact your municipal water company or your local health department for a list of contaminants in your area and a list of laboratories certified by your state to analyze drinking water. WARNING: Before using the Reverse Osmosis system for the first time, the system must be purged. The Reverse Osmosis cartridge contains a food grade preservative that must be purged from the system. The preservative will give product water an unpleasant taste and odor. ¦ This product reduces fluoride in drinking water. Please consult your dentist if you have questions. WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not reduce other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information. This Reverse Osmosis system contains a replaceable treatment membrane cartridge critical for effective reduction of Total Dissolved Solids. The water should be tested periodically to verify that the system is performing satisfactorily. See the About the Water Test Kit section. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280kPa (40 psig) or greater. PROPER INSTALLATION AND MAINTENANCE This Reverse Osmosis system must be properly installed and located in accordance with the Installation Instructions before it is used. ¦ Install or store where it will not be exposed to WARNING: Discard all unused parts and temperatures below freezing or exposed to any type of weather. Water freezing in the system will damage it. Do not attempt to treat water over 100°F. ¦ Do not install on HOT WATER. The temperature of the water supply ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias