Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação GE, Modelo GXRV10ABL01

Fabricante : GE
Arquivo Tamanho: 1.58 mb
Arquivo Nome : 5b649be5-a0e8-4992-bdb3-8cbbcda808b7.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Also, before sanitizing, be sure to remove all cartridges as described in the Sanitizing the Reverse Osmosis System section. Chlorine will destroy the Reverse Osmosis cartridge. 1 Complete Cartridge Replacement and Sanitize the System procedures (see pages 6–8), except reinstall the filters provided with the unit. 2 Purge membrane. See Step 12 in Reverse Osmosis Cartridge Replacement section. 3 Carefully check the system for leaks. Installation Checklist 1. Are all tubing connections tightened? Do they run between the points shown? No leaks! 2. Did you use drain option B, C or D? Make sure the 3/8. drain tubing, from the faucet to the drain point, is without loops, dips or low spots. 3. Is the water supply shutoff valve open? 4. Did you sanitize and purge the system? 18 Before you call for service… Troubleshooting Tips Save time and money! Review the charts on the following pages first and you may not need to call for service. Problem Possible Causes What To Do Sounds you might hear Running water from the unit to a drain. • This is normal. Water has air bubbles and is cloudy Air in system after installation. • Will go away after water runs for a while. Chlorine taste and/or odor in the Reverse Osmosis product water The ppm of chlorine in your water supply exceeds maximum limits and has destroyed the Reverse Osmosis membrane. • If the water supply contains more than 2.0 ppm of chlorine, additional filtering of the water supply to the Reverse Osmosis is needed. Correct this condition before doing maintenance on the Reverse Osmosis system. The prefilter is no longer removing chlorine from the water supply. • Replace the Reverse Osmosis membrane cartridge, control, screen, prefilter and postfilter. Other taste and/or odor High quality product water may have a different taste than what you’re used to. • This is normal. Low water usage. • Completely drain system and allow to refill. Contamination in product water storage. • Use sanitizing procedures. Prefilter and postfilter need to be changed and/or the Reverse Osmosis cartridge needs to be changed. • Replace the prefilter and postfilter. If taste and odor persists, replace the Reverse Osmosis cartridge, flow control and screen. Water leaking from faucet air gap hole Drain side of faucet air gap (3/8. tubing) plugged, restricted or incorrectly connected to the drain point. • Inspect and eliminate restriction or plug. It is important that there are no dips, loops or low spots in the drain line from the faucet air gap to the drain pipe. Refer to the Filtration Drain Connection Installations section, for proper drain connection. If drain line adapter was used as the drain point, periodic inspection/cleaning is recommended. System makes product water slowly This is normal. • Water flow rate will be lower than your regular faucet. Water supply to the Reverse Osmosis system not within specifications. • Increase water pressure, precondition the water, etc., as needed to conform before doing maintenance on the Reverse Osmosis system. Prefilter cartridge plugged with sediments and/or the Reverse Osmosis cartridge plugged with sediments. • Replace the prefilter. If rate does not increase, replace the postfilter, Reverse Osmosis cartridge, flow control and screen. Consumer SupportTroubleshooting Instructions Installation 19 * NOTE: Codes in the State of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts. Parts list. 20 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions General Electric parts catalog. REF. NO. PART NO. PART DESCRIPTION GXRV10ABL01 0001 WS15X10024 FAUCET BLACK TIP & LEVER 1 0002 WS08X10002 GASKET TOP 1 0008 WS03X10003 ADAPTOR TUBING 1 0009 WS22X10005 NUT 1/4. TUBE 8 0010 WS22X10006 INSERT 1/4. TUBE 7 0012 WS22X10007 INSERT 3/8. TUBE 7 0013 WS22X10008 NUT 3/8. TUBE 7 0014 FX12P PRE & POST FILTERS 2 0021 WS10X10005 VALVE BOTTOM 1 0022 WS22X10009 DIAPHRAGM 2 0023 WS22X10010 PLUNGER 1 0024 WS22X10012 ELBOW 1/8. NPT X 1/4. 1 WS22X10011 ELBOW 1/8. NPT X 1/4. & NUT 3 0025 WS22X10013 CONNECTOR W/NUT 1/8. NPT 1 0026 WS10X10006 VALVE TOP 1 0027 WS10X10007 VALVE CENTER 1 0028 WS02X10010 SCREW #10-14 X 1-3/4. 4 0030 WS32X10012 TANK 1.3 GAL. 1 0032 WS02X10018 CLIP 2 0033 WS02X10017 SCREW 4 0035 WS35X10033 HOUSING & CHECK ASM 1 0041 WS15X10023 SADDLE VALVE–SUPPLY* 1 0042 WS18X10006 DRAIN LINE ADAPTER–DLA9 1 0043 WS03X10015 SCREEN CONE 1 0044 WS03X10042 CONTROL FLOW 1 0045 FX12M RO CARTRIDGE 1 0050 WS07X10008 TUBING 3/8. X 20 FT–WH 1 WS07X10005 TUBING 1/4. X 10 FT–BL 1 WS07X10007 TUBING 3/8. X 20 FT–BL 1 WS07X10006 TUBING 1/4. X 20 FT–WH 1 0051 WS15X10014 SHUTOFF ASSEMBLY 1 0059 WS02X10020 SCREW, #10 X 1/2. 8 0060 WS28X10008 BRACKET 1 0061 WS19X10007 HEAD 2 0062 WS22X10002 ELBOW 3/8. NPT X 3/8. 2 0063 WS03X10001 O-RING 3-3/8. X 3-5/8. 2 0064 WS3...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias