Log:
Assessments - 5, GPA: 3.4 ( )

Instruções de Operação Bacharach, Modelo Fyrite 24-9429

Fabricante : Bacharach
Arquivo Tamanho: 400.58 kb
Arquivo Nome : d5b0452d-2f16-49d1-b849-d42bbb27baf1.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Fan Assist or Power Vented Furnace/Boiler 02, CO, Stack Temp. Combustion Air Sampling Point 90% Eff. Condensing Furnace/Boiler BACHARAOi’ Measurable Difference Fyrite® Tech 50 & 60 Quick Start Guide 24-9429 Rev. 1 - September 2003 This Guide provides basic information about how to turn ON the analyzer and conduct a combustion efficiency test. Detailed information concerning the analyzer’s operation, set up, and calibration is contained in Instruction 24-9428. Turning ON the Analyzer 1. Place the probe tip in the area that contains the burner’s combustion-air source. This step allows the analyzer to measure the combustion-air temperature during the analyzer’s warm-up period. 2. Press analyzer’s I/O button. Water Trap / Filter Maintenance Drain the water condensate collected in the water trap after every test. Replace the filter element (P/N 07-1644) when dirty. Pull apart using a slight twisting motion Pry apart filter chamber using a small flat-blade screwdriver inserted into notch WATER TRAP CHAMBER FILTER CHAMBER FILTER ELEMENT “A”^J When reassembling L “B” the trap, make sure that surfaces “A” and “B” are in contact 3. Wait for the analyzer to complete its 60 second warm-up period. Performing a Combustion Test 4. Press the ▲ or ▼ button to select the desired fuel and then press ENTER. The fuel codes are: F1 = Natural Gas F2 = Oil #2 F3 = LPG F4 = Kerosene Example: “F1” denotes Natural Gas Bacharach, Inc. 621 Hunt Valley Circle, New Kensington, PA 15068 Ph: 724-334-5000 • Fax: 724-334-5001 • Toll Free: 800-736-4666 Website: • E-mail: help@bacharach-inc.com - 5 - - 6 - Printed in U.S.A. 5. Press the ▲ or ▼ button to display the “Stack Temperature & Efficiency” Screen. H00I 18.1 6. 7. 8. 9. Insert probe into the burner’s flue-gas stream (see Sampling Locations on Pages 5 and 6). Burner-service procedures can now begin. The readings diplayed on the analyzer will update continuously, showing the changes in burner performance. Use the ▲ and ▼ buttons to scroll through the analyzer’s other screen displays while a test is in progress. (The order in which the screens are displayed is shown on Pages 3 and 4.) Press the HOLD button to stop the pump and freeze all readings. Press ENTER to resume testing. Ending a Combustion Test /j\ WARNING! Burn hazard. Do not touch the probe after removing it from the flue-gas stream. Allow the probe to cool before handling (about 5 minues). 10. End a test by first removing the probe from the flue-gas stream, and then allowing the pump to run until the O2 reading reaches approximately 20.9%. Turning OFF the Analyzer 11. Turn OFF the analyzer by pressing the I/O button. There is a 5-second delay before the analyzer actually turns OFF, during which time the unit can be turned back ON by pressing the ENTER button. A Fyrite Tech 60 will not turn OFF if a high level of CO is still being detected. The pump will remain running and the message “PurG CO” i...

Este manual também é adequado para os modelos :
Purificadores de água - Fyrite Tech 50 (400.58 kb)
Purificadores de água - Fyrite Tech 60 (400.58 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias