Log:
Downloads : 17   Arquivo Tamanho: 753 kb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

Hilex, Clerox, etc.) and mix in the water. DO NOT ADD CHLORINE FIRST. Concentrated, it will attack plastics, 6. Replace the cap, with o-ring, and install the retaining clamps. 7. Connect the RO faucet product water tubing directly to the tank shutoff valve, isolatinq the carbon postfilter. 8. Open the tank shutoff valve, and the water supply to the RO. Open the RO faucet, locking the lever upward, against the spout. 9. Allow water to circulate through the system until the bleach odor is gone. 10

Downloads : 0   Arquivo Tamanho: 411 kb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

Then, carefully push it straight down into the salt. If a hard object is felt before the pencil mark gets to the top of the tank, it’s most likely a salt bridge. Carefully push into the bridge in a few places to break it. Do not try to break the salt bridge by pounding on the outside of the salt tank. You may damage it. If the wrong kind of salt made the bridge, take it out. Then fill the tank with nugget or pellet salt only. FIG. 9 SALT BRIDGE 14 SECTION 3 CARE OF YOUR SOFTENER 3B. KEEPI

Downloads : 7   Arquivo Tamanho: 411 kb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

Then, press SELECT again and hold until an SR code appears. It must show SR21. If any other SR number shows, the softener computer is working on incorrect input and would probably be the cause of the problem. To set SR21, press either the UP |A)or DOWN Ivbutton. Then press select to return a flashing 12:00 AM display, and reset the timer, page 6. PROBLEM CAUSE CORRECTION NO SOFT WATER No salt (or salt bridged) in the storage tank Refill with salt, or break the salt bridge (page 14). Press ON/O

Downloads : 9   Arquivo Tamanho: 1 mb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

DO NOT ATTEMPT TO LIFT IT BY YOURSELF. DO NOT DROP AND BREAK THE TANK. . Stand the tank upright and replace the bottom distributor assembly. Temporarily, plug the top end of the distributor (use rag, etc.) to prevent accidental mineral spills into it. 1 Using a large neck funnel (FIG. 6), first add 17 Ibs. of gravel, followed by 10 Ibs. of filter sand. Next, add the 1 cu. ft. of activated carbon. Use water sparingly to assist carbon flowthrough the funnel. NOTE: Be sure the bottom distributor is

Downloads : 0   Arquivo Tamanho: 1 mb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

STEPS TO ADD MINERAL 1. Press the face plate BACKWASH NOW button [] and hold for 3 seconds, until RCHG begins to flash in the display. 2. When water begins to flow from the valve drain hose, place the bypass valve(s) in BYPASS position.., see FIG. 8, page 18. CAUTION: BE SURE TO DO STEPS 1AND2 AS INSTRUCTED, TO RELIEVE WATER PRESSURE IN THE TANK. 3. Unplug the transformer at the wall outlet. 4. Carefully, pull the 2 clips (key #41, page 26) at the inlet and outlet fittings. Slide the adaptors, o

Downloads : 0   Arquivo Tamanho: 1 mb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

The neutralized or non-acid water then flows into the house water pipes. Because the neutralite does dissolve, you have to add new mineral at least once each year, and sometimes more often (see page 14). TASTE AND ODOR FILTER The taste and odor filter is filled with activated carbon. As water flows into and DOWN through the filter (FIG. 5), the tastes and/or odors are adsorbed and held by the carbon. Water without bad tastes or odors goes into the house pipes. When the activated carbon no longer

Downloads : 1   Arquivo Tamanho: 745 kb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. . Unplug fixture from power. . Use a vacuum or air compressor and a soft brush to remove dust collected on external vents. . Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. . Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. . Gentl

Downloads : 4   Arquivo Tamanho: 662 kb   Fabricante : Everpure  
Categoria : Purificadores de água
@name@name

Never allow the inspection and maintenance space to be blocked. Refer to the WSS Electrical Specifications for voltage information. Refer to the WSS General Specifications in this section to determine if there is adequate clearance for the machine. If there is not and the WSS needs to be removed, refer to the previous section “Removing Top Section”. 1. Connecting the WSS to washer-extractor: NOTE: The tank drain hose assembly is packaged inside washer-extractor basket. a. Remove tank drain

Downloads : 1   Arquivo Tamanho: 193 kb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

The the Cartridge O-Rings is facing outward "RESET?" will be flashing. (See Figure 13.) (toward the base). Make sure that the Housing O-Ring is In the Filter Housing and screw the Filter Housing onto the Filter Base. (See Figure 12,) 7, Place the Filter System right side-up with the Faucet pointing into the sink. BUttON Rinse the Filter System for 5 minutes to remove carbon fines and expel excess Figure 13 air, Be certain to reset the meter after you have comDletelv rinsed the system !! Press gr

Downloads : 0   Arquivo Tamanho: 847 kb   Fabricante : Everpure  
Categoria : Purificadores de água
@name

CGS-23 20" Parallel Housing Foodservice System Housing for Drop-In Cartridges CGS-23 20" Dual Parallel Housing: DEV9100-23CGS-23 20" Dual Parallel Housing: DEV9100-23 20" low profile Slim Line dual bowl housing in Parallel configuration Manufactured of durable polypropylene and has excellent chemical resistance System includes pre-mounted water pressure gauge Equipped with a pressure relief button to relieve water pressure during cartridge changes Includes wall mounting bracket and hardware for