Log:
Assessments - 5, GPA: 3.6 ( )

Instruções de Operação Kenmore, Modelo 437.85264

Fabricante : Kenmore
Arquivo Tamanho: 1.26 mb
Arquivo Nome : 54476b43-b0eb-4e97-8a10-279a3be27736.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Save these instructions for easy reference. When using electrical appliances, basic precautions should always be followed to reduce breakage, risk of fire, electric shock and injury to persons including the following. o Read all instructions before operating the air cleaner. o Place the air cleaner where it is not easily knocked over by persons in the household. o ALWAYS unplug air cleaner when not in use. o DO NOT use any product with a damaged cord or plug, or if product malfunctions, is dropped or damaged in any manner. o Keep the power cord away from heated surfaces. o DO NOT use air cleaner outdoors. o NEVER use the air cleaner unless it is fully assembled. o DO NOT run power cord under carpets and DO NOT cover with throw rugs. Arrange cord so it will not be tripped over. o DO NOT use air cleaner where combustible gases or vapors are present. o DO NOT expose the air cleaner to rain, or use near water, in a bathroom, laundry area or other damp locations. oTo disconnect air cleaner, first press Power Button to turn air cleaner OFF and remove plug from outlet. • DO NOT allow foreign objects to enter ventilation or exhaust opening, as this may cause electric shock or damage to the air cleaner. DO NOT block air outlets or intakes. o Place air cleaner near a power outlet, and avoid using an extension cord. oTo reduce the risk of electric shock, this equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet, Do not alter the plug in any way. oThe air cleaner has a 3-prong (grounded) plug for safe operation. The 3-prong plug should be plugged directly into a properly grounded 3-prong electrical outlet. DO NOT, FOR ANY REASON WHATSOEVER, CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG. Removing the grounding plug may result in electric shock or create unsafe condition. Contact a qualified electrician to be sure the outlet is properly grounded. ° A loose fit between the plug and the AC outlet (receptacle) may cause overheating and distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles. -DO NOT sit, stand or place heavy objects on the air cleaner. o ALWAYS disconnect power supply before servicing. DO NOT use this product with any solid-state speed [_1 ARNING!Toreducetheriskoffireorelectricshock, control device. ONEoyEAR FULL WARRANTY ON KENiViORE AIR CLEANER For one year from the date of purchase, when operated and maintained according to the owner's manual, if any part of this air cleaner fails due to a defect in material or workmanship, RETURN ITTO ANY SEARS STORE OR OTHER KENiVIORE OUTLET mNTHE UNITED STATES FOR FREE REPLACEMENT. This warranty is void if this product is used for commercial or rental purposes. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179 INTRODUCTION Congratulations on your choice of the Kenmore Electrostatic Air Cleaner. Your new Air Cleaner System quickly and effectively cleans and revitalizes indoor air electrostatically, reducing most commonly found air pollutants such as tobacco smoke, pollen, household dust, pet dander, even mold spores. Designed for outstanding owner convenience, the air cleaner features a washable pre-filter and collecting cell, so there are no filters to buy and replace. Four cleaning power levels let you match the Air Cleaner's performance to your special needs. All operating functions are easily set and adjusted on the well-lighted, user-friendly LCD control panel. For maximum performance, we highly recommend that you operate the Electrostatic Air Cleaner in the following manner: o24 hours a day o Ionizer ON for the first day o Ionizer OFF after first day o Ionizer ON when you require quick cleaning and extra refreshing of room air SETUP Your Electrostatic Air Cleaner was thoroughly inspected and tested at the factory prior to packaging. Visually inspect it upon removal from the box. Remove and discard any packing material. Return the unit if it shows any signs of damage or mishandling. Contents: o Electrostatic Air Cleaner o2 Protective Screens (Only used when cleaning the Collecting Cell in a dishwasher...see pg. 12) Place air cleaner near a power outlet, and avoid using an extension cord. Lock the caster wheels to prevent the air cleaner from moving. ELECTRICAL HOOKUP Plug the Electrostatic Air Cleaner into a properly grounded, 3oprong household AC outlet. If you are not sure whether the outlet is properly grounded, have it checked out by a qualified electrician. WARNING! To avoid the risk of fire or electric shock hazard, the Electrostatic Air Cleaner should ONLY be plugged into a properly grounded 3-prong, 120-Volt AC outlet. CAUTION: NEVER operate the Electrostatic Air Cleaner until it is completely and fully assembled. Perman...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias