Power Cord 1. Check to make sure power cord is plugged in or properly connected to HVAC unit. 2. AHPCO™ Cell 2. Check to make sure UV lamp within AHPCO™ Cell in plugged in completely. 3. Indicator Light Not Working 3. Make sure exposed end of black fiber optic cord is exposed to the UV light. 3401 Airway Blvd Amarillo, TX 79118 Toll-Free: 1-800-936-1764 Fax: 1-806-373-7799 Copyright© 2006 Air Oasis All Rights Reserved Dual Induct (120v) Owner’s Manual This Manual Includes: • Warranty • Safety Warnings • Installation Instructions • Operating Instructions • Replacement Directions • Troubleshooting Tips Before operating this unit or replacing the AHPCO™ Cell carefully read the contents of this manual. Important Safety Instructions When operating electrical appliances, basic precautions should always be followed. WARNING To reduce the risk of fire, electric shock or injury: • Do not use outdoors or on wet surfaces. • Use only as described in this manual. • Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, call customer service at 1-800-936-1764. • Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. • Do not handle plug or appliance with wet hands. • Do not put any object into openings. • Turn off all controls before unplugging. CAUTION AHPCO™ Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at If the UV lamp is broken do not touch the cell or glass with your hands. UV lamp may be hot and could cause serious burns if not handled properly. Please wait until the AHPCO Cell has cooled to room temperature to remove from unit. WARNING: UV Light Hazard. Harmful to skin and eyes. Can cause temporary or permanent loss of vision. Never look at the lamp while illuminated. To prevent exposure to ultraviolet light, be sure the power is disconnected before servicing. WARNING: RISK OF ELECTRICAL SHOCK. CAN CAUSE INJURY OR DEATH: UNPLUG OR DISCONNECT UNIT FROM POWER SUPPLY BEFORE SERVICING. Disclaimer – The health aspects associated with the use of this product and its ability to aid in disinfection of environment air have not been investigated by UL, located on front panel of fixture and in the instruction manual. 1 Step 3 Remove four (4) wing-nuts securing the AHPCO Cell in place. Then slide the AHPCO Cell up and out of the unit. CAUTION UV lamp may be hot and could cause serious burns if not handled properly. Please wait until AHPCO Cell has cooled to room temperature to remove from unit. AHPCO™ Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at org. Step 4 Reverse steps 1-3 to set new AHPCO Cell in place. Be sure to place the exposed tip of the fiber optic cord between the first rings of the new AHPCO Cell and in close proximity to the UV lamp. This will ensure the indicator light functions properly. Replacement Date Reminder The AHPCO™ Cell should be replaced every three years. 3 Years Date: 6 Years Date: 9 Years Date: Hg lamp contains mercury. Manage in accord with disposal laws. Find disposal centers at 6 Dual Induct Installation Instructions Step 1 Tear out the cutout template and trace the rectangle onto the ductwork. Step 2 Drill holes at each corner of the rectangle. Step 3 Cut the rectangle out of the ductwork with a jig saw or a pair of metal cutting snips. Step 4 Remove the wax paper from the gasket. Step 5 Insert unit into pre-cut hole. Step 6 Drill the metal tapping screws in to hold unit in place. Tear this page off and cut the rectangle out. Then place on the duct work in desired position and trace the rectangle. Drill holes as indicated and then use a jig saw or metal cutting snips to cut out the rectangle. Cut Out Step 4 Plug the power cord into an electrical outlet. You may optionally have an electrician wire the air purifier to your HVAC unit so that the air purifier only operates when your HVAC fan is running. Once the unit is plugged in the indicator light should glow to indicate the AHPCO Cell is working properly. AHPCO™ Cell Replacement Step 1 CAUTION: Before attempting to service the Air Oasis unit, be sure the power is off and unplugged. Remove three (3) screws at the top of the aluminum face plate. Then slide the face plate up and off. Step 2 Unplug the four pin lamp connectors and fiber optic cords from the AHPCO Cell. 5 Read all instructions carefully before operating your air purifier. Table of Contents Safety Instructions and Cautions 1 Table of Contents 2 Warranty 3 Maintenance and Customer Service 4 Placement and Operation 4 Cleaning 4 AHPCO™ Cell Replacement 5-6 Troubleshooting Guide 7 2 Warranty Air Oasis gives you the following limited warranty for this product only if it was originally purchased for residential or commercial use but, not resale from Air Oasis or an Air Oasis Authorized Retail Dealer....
Escreva a sua própria avaliação do dispositivo
|
|