Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Vornado, Modelo AQS500 Air

Fabricante : Vornado
Arquivo Tamanho: 3.39 mb
Arquivo Nome : 625d7ab1-fd5a-4b86-af23-d7775639f4c4.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. WARNING - To reduce the risk of fire or electric shock, do not use this product with any solid-state speed control device. WARNING - Unplug the appliance from the power supply before cleaning, moving or servicing. Do not use on wet surfaces. Do not run power cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange the power cord away from traffic areas, so it will not become a tripping hazard. Do not use gasoline, thinners, solvents, or other chemicals for cleaning. Do not immerse the power head in water or allow water to drip into the motor housing. Do not use immediately next to furnaces, fireplaces, stoves, or other high-temperature heat sources. This air cleaner is intended for floor use only. Always place on a firm, flat surface. Do not position too close to draperies as they me be drawn into the inlet grills cutting off airflow. Do not use outdoors. Do not operate the air cleaner with a damaged cord or plug or if the air cleaner malfunctions, or has been dropped or damaged in any manner. Return to Vornado® for examination, electrical or mechanical adjustment, or repair. Do not attempt to repair or replace parts other than filters. Do clean your Vornado air purifier regularly. Refer to the CLEANING instructions provided. Never clean the air cleaner in any manner other than as instructed in this manual. USE COMMON SENSE WHEN USING YOUR VORNADO AIR PURIFIER OR ANY ELECTRICAL APPLIANCE. SAVE THESE INSTRUCTIONS ENGLISH 2 Cleaning the air with the Vornado® Air Quality System 500 Congratulations on the purchase of the Vornado Air Quality System 500. Vornado delivers Whole Room Air Circulation, unlike most air purifiers. Our engineers have applied Vornado's signature Vortex Technology to the AQS 500 to provide complete circulation of the air in the room and deliver optimal cleaning. As the air passes through two Vornado Allergen Reducing Filters, serious allergens including dust, pollen, pet dander, smoke, bacteria, mold spores and dust mite debris are captured. Features and Benefits Save money with a product that uses less energy than a 40-watt light bulb.* A. Live better in pure air as the air in the room is circulated and filtered using Vornado's signature Vortex Technology B. Depend on Vornado for quality craftsmanship, backed by a 5-year limited warranty C. Experience the performance of 2 Allergen Reducing Filters D. Position against a wall or in a corner without affecting performance E. Enjoy near silent operation, as quiet as a desktop computer** F. Take control of your environment with features like a remote control, timer, speed settings and change filter indicator quiet and normal speed settings. **on quiet speed setting. ENGLISH 3 How to Use POWER CO) The unit functions ON and OFF by pressing the POWER button. FAN SPEED (®) The fan speed can be adjusted by pressing the SPEED button. Press the button to switch between the unit's three speed settings. Lights on the unit's control panel indicate the selected speed setting. Use QUIET speed for quiet but effective cleaning. Use NORMAL speed for normal air cleaning needs. And use QUICK CLEAN speed for maximum cleaning and circulation. Dust and allergens are most airborne when persons are active in the room, so you may want to use the AQS 500 on higher speeds when people and pets are active and on a lower setting when activity is reduced. TIMER (©) The unit has an automatic timer to turn the unit ON or OFF at intervals of 4, 8 or 12 hours. Settings can be adjusted directly or by using the remote control. To set the unit to turn OFF - while the unit is running, press the timer button until the desired time light is lit. The unit will continue to run until that amount of time has expired. To set the unit to turn ON - while the unit is OFF, press the timer button until the desired time light is lit. The unit will remain off until that amount of time has expired and then the air cleaner will turn on. The unit will restart on the last speed setting used before turning off. CHANGE FILTER INDICATOR (A) The unit is equipped with an indicator light to show when it is recommended to change the filters. This feature is controlled by time of use. The light will come on when 4,000 hours of run time have accumulated. It is suggested that this would be a good time to check and change the filters. Unclean filters will diminish the air quality performance. Filters with significant visible buildup of dust and debris should be changed whether the change filter light has activated or not. ENGLISH 4 How to Use REPLACING FILTERS To replace used filters, unplug the unit, and lift off the power head from the base. Simply lift out the...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias