Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Trion, Modelo ELIMINATOR SE800E

Fabricante : Trion
Arquivo Tamanho: 1.17 mb
Arquivo Nome : trionse400eowners.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


154385-002 • September 2001 1 Contents Section I – Design Page 1. Introduction……………………….. 3 2. The Filter System………………… 3 3. Specifications…………………….. 4 Section II - Installation 1. Installation………………………… 5-6 2. Diagrams………………………….. 7 Section III – Servicing and Maintenance 1. Servicing / Maintenance………… 8 2. Parts List………………………….. 9 3. Exploded Views………………….. 10 Section IV - Reference 1. Wiring Diagram SE400E………… 11 2. Wiring Diagram SE 800E……….. 12 This manual provides information for installation, operation and maintenance of your Trion SE400E & SE800E. Before installing and using the air purifier, carefully read these instructions to ensure maximum benefits from the unit, and to avoid needless service costs that may result from improper installation and maintenance. 2 Eliminator SE Series Section I – Design 1. Introduction The Trion Eliminator SE400E & SE800E are commercial air purifiers that have been specifically designed to remove airborne pollutants - including tobacco smoke, dust, pollen and mold spores - in rooms and areas where people work or relax. They are designed to be mounted onto a solid ceiling, semi-recessed for into a suspended ceiling, or wall mounted (SE400E only). Where appropriate they can also draw in additional fresh air. Their features make them the ideal air purifier for installations into areas such as offices, conference rooms, restaurants, designated smoking areas, institutions and waiting rooms or any other place where people gather. HOW THEY WORK The Trion SE400E & SE800E utilize the principle of Electrostatic Precipitation. Air is drawn into the intake, through the metal prefilter, which traps lint and large dust particles. The remaining particles, some as small as 0.01 microns*, pass into a strong electrical field (ionizing section) where the particles receive an electrical charge. The charged particles pass onto a series of equally spaced parallel plates (collector section). Each alternate plate is charged with the same polarity as the particles, which are repelled, while the interleaving plates are grounded, and therefore attract and collect the particles. * The diameter of a human hair is about 100 micron! 2. The Filter System There are two filters in your air cleaner THE PRE-FILTER: This is the mechanical filter that lies behind the inlet grill. It is designed to remove large particles and can be washed many times before replacement. THE ELECTROSTATIC FILTER: This is the deep aluminum assembly (Collector Cell) located immediately behind the pre-filter and is the heart of your air cleaner. It uses an electrostatic charge to remove particles so small that it would take a pile of many millions to cover a pinhead. When dirty it can be washed and reused indefinitely. FILTER REMOVAL TRION SE400E Turn the control switch off before removing cell. Press the two cell access latches and the hinged door will swing down. Remove pre-filter by turning pre-filter clip 90 degrees (fig 2). While supporting the weight of the Collector Cell, loosen the filter retaining screw (fig 3). The filter retaining plate will now open allowing the filter to be removed (fig 4). To reinstall the filter, simply reverse above procedure. TRION SE800E The two hinged access doors are secured with retaining screws (fig 3). Release screws to allow the doors to swing down. Remove the Collector Cells as described above. INSTALLATION LOCATION The most effective location for the air purifier is the center of the area to be cleaned because the dirty air is pulled into the center of the unit and discharged equally out the four sides. If more than one unit is required, space them evenly over the area to be cleaned. 3 Eliminator SE Series 3. Specifications Model SE400E SE800E Dimensions Depth: Width: Length: 9.5” 22.5” 22.5” Depth: Width: Length: 9.5” 22.5” 46.12” Installation Surface mounted, recessed into suspended ceiling, or wall (SE400E only) mounted. Weight 42 lbs. / shipping 48 lbs. 80 lbs. / shipping 86 lbs. Input Power 120 Volts, 1 Phase, 60 Hz 120 Volts, 1 Phase, 60 Hz Power Consumed 1.8 Amps, 155 Watts 3.4 Amps, 270 Watts Controls Hard-wired remote control Hard wired remote control with 3-speed selector switch with 3-speed selector switch with air-dry (fan only) facility with air dry (fan only) facility Motor 1/20 HP, 3-speed, Ball Bearing (2) 1/20 HP, 3-speed, Ball Bearing Air Flow 200, 300, 400 CFM 400, 600, 800 CFM Sound Rating 38, 55, 62 dBa 41, 58, 65 dBa Safety Feature Interlock to cell access door Interlock to cell access door Features Anti-arc circuitry Anti-arc circuitry Power to cell indicator Power to cell indicator Fresh air inlet Fresh air inlet Dry (fan only) cycle Dry (fan only) cycle Options Infrared remote control Infrared remote control Fresh air damper system Fresh air damper system 4 Eliminator SE400E & SE800E Section II – Installation 1. INSTALLATION CAUTION: ELECTRONIC AIR CLEANERS CANNOT BE USED IN AREAS WHERE COMBUSTIBLE GASES OR VAPORS ARE PRESENT. MECHANICAL The unit has been desi...

Este manual também é adequado para os modelos :
Air - ELIMINATOR SE400E (1.17 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias