Fabricante : Trion
Arquivo Tamanho: 161.39 kb
Arquivo Nome : fb932f6b-1f64-4d52-b9ef-cd1d4b1c0fd3.pdf
|
Facilidade de uso
The FM 1000 Provides: • Multiple Model Selection — There are two models to choose from: the FM 1000E (electronic air cleaner) and the FM 1000M (media air cleaner). So, there’s an FM 1000 that can meet virtually any scenario. • Easy Installation — These units feature a low-profile design that is not only appealing to the eye, but requires no elaborate ductwork or installation. • High Performance — Each of these units is capable of removing up to 95% of tobacco smoke, dust, pollen, lint, bacteria, and mold spores from indoor air. •Flexible Performance — Each unit features three convenient speeds, ranging from 400 to 1100 cfm (680 – 1879 m3/hr) to quickly and easily meet the demands of the environment. • Affordable Operation — Because these units recirculate indoor air, there’s no expense to reheat or cool air. And the FM 1000E features a Forever Filter® that never needs to be replaced; just clean, dry, and reinstall. • Additional Odor Control — The optional charcoal after-filter helps control the smell of gas and other odors. • Super-Effective Air Cleaning — The optional remote discharge allows wider separation between intake and discharge areas. This means more effective air cleaning. Powerfully-Effective Airflow Pattern The FM 1000E and FM 1000M models feature “center suction” dirty air intake and discharge returned clean air in six directions, so clean air circulates faster. That means happier, more comfortable patrons, employees, or guests. FM 1000 ELECTRONIC / MEDIA AIR CLEANERS FM 1000 ELECTRONIC / MEDIA AIR CLEANERS Aluminum Mesh Pre-Filter Removable 6-Way Air Discharge 3-Speed Switch FM 1000E Ionizer- Collector or FM 1000M Media Filter FM 1000E The Trion FM 1000E utilizes the principle of “electrostatic precipitation.” Dirty air is drawn into the center intake by the motor/blower, and is moved through the washable, aluminum mesh pre-filter where lint and large dust particles are trapped. The remaining particles, some as small as .01 micron, pass into a strong electrical field (ionizing section) where each particulate receives an electrical charge. These charged particles then pass into a collector plate section made up of a series of equally-spaced parallel plates. Each alternate plate is charged with the same polarity as the particles, which are repelled, while the interleaving plates are grounded, and attract and collect the particles. Clean air is then discharged in six directions back into the area. FM 1000M The Trion FM 1000M utilizes a principle called “interception filtration.” In the first stage of this two-stage process, dirty, polluted air is drawn into the center intake by the motor/blower and is moved through the washable, aluminum mesh pre-filter to remove lint and larger dust particles. In the second stage, the micro-glass deep pocket media filter strips smoke and other submicron particles from the air stream by interception. The small diameter fibers in the filter intercept and retain these small particles while the large surface area of the filter provides long life and low pressure drop. Clean air is then discharged in six directions back into the area. The quiet blower is designed specifically to handle the two-stage filtration system at rated CFM (m3/hr) over the useful life of the filter. Filter Access Door FM 1000 DIMENSIONS FM 1000 DIMENSIONS POSITIONING BRACKET & FILLER STRIP AIR AIR AIR FLOW INLET FLOW REMOTE DISCHARGE OPTION 2.75” KNOCKOUTS FOR POWER CONNECTION 7/8” (22 mm) DIA. POSITIONING 2 REQUIRED POSITIONING BRACKET 2 REQUIRED POSITIONING POSITIONING BRACKET 2 REQ’D @ EACH END AIRFLOW END.50” (13 mm) TYP. 2.75” (70 mm)1.50” (38 mm) (70 mm) 1.50” (38 mm) 5.38” 137 mm 2.90” (74 mm) 10.00” DIA. 1.125” (29 mm) TOP SIDE AIR FLOW AIR FLOW AIR FLOW AIR INLET AIR FLOW AIR FLOW AIR FLOW 22.88” (581 mm) KNOCKOUTS FOR POWER CONNECTION 7/8” (22 mm) DIA. 8.00” (203 mm) 8.00” (203 mm) 0.54” (14 mm) 12.25” (311 mm) FIELD WIRING COMPARTMENT COVER 19.63” (499 mm) 1.125” (29 mm) 19.63” (499 mm) AIRFLOW 24.25” (616 mm) 25.08” (637 mm) 22.88” (581 mm) 47.25” AIR (1200 mm) AIR FLOW FLOW BRACKET BRACKET 2 REQ’D @ EACH END FM 1000 ELECTRONIC / MEDIA AIR CLEANERS SPECIFICATIONS FM 1000 ELECTRONIC / MEDIA AIR CLEANERS SPECIFICATIONS FM CINORTCELE•E0001 MODEL PART NO. DIMENSIONS INSTALLATION WEIGHT ELECTRICAL MOTOR BLOWER AIR VOLUME CONTROLS SOUND RATING FILTER EFFICIENCY PRE-FILTER PRIMARY FILTER INCHES (mm) LBS (kg) 440515-001 471/2 L x 22 7/8 W x 19 5/8 D (1207 x 581 x 499) Above ceiling / flush mount 108 (49) / shipping 240 (109) 120 V, 60 Hz, 1 ph-3.1 amps 1/3 hp (.25 kW) ball bearing, direct drive, thermally protected Propeller fan 600, 800, 1100 cfm (1020, 1360, 1870 m 3/hr) 3-speed, power “ON” light, “to cell” light 49, 56, 65 dB Up to 95% per ASHRAE 52.1 / dust spot Aluminum mesh Forever Filter® – permanent aluminum collector cell Standard Specications For Each Unit CABINET 20-Gauge (1.0 mm) galvanized steel FINISH Almond epoxy powder-coat paint AIR FLOW 6-Way discharge, Coanda ow FILTER ...