Log:
Assessments - 5, GPA: 3.8 ( )

Instruções de Operação Hunter Fan, Modelo 30170

Fabricante : Hunter Fan
Arquivo Tamanho: 1.06 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


41451-01_Rev 8-6-04.pmd 12 8/5/04, 5:05 PM Programming NOTES: • The clock flashes when the time has not been set. • At any time while you are setting the Day/Time, you can press the PROGRAM key to toggle between AM/PM format and military time format. •To quickly exit the Day/Time setting mode, you can press the DISPLAY key or wait 15 seconds without pressing any keys. •The time displayed will be frozen in Day/Time setting mode; however, the internal clock is still running. If no value is changed, then the frozen time will be replaced by the internal clock when you exit the Day/Time setting mode. • If the power is lost to the unit, the memory will maintain the clock for at least 12 hours. Pre-set Programming As discussed in the Manual and Auto Operating Modes section of the manual (pg. 9), your air purifier comes with pre-set programs. For your reference, these programs are listed again below. When you turn your air purifier to Auto Mode, these programs are active unless you override them with your personalized programs. Refer to the next section, User Programming, to learn how to input your own programs. Table 3: Pre-set programming provided for each air purifier. Program Setpoint Time Blower Speed 1 8:00 am 2 (Medium) 2 3:00 pm 3 (High) 3 5:00 pm 2 (Medium) 4 10:00 pm 1 (Low) 13 41451-01 41451-01_Rev 8-6-04.pmd 13 8/5/04, 5:05 PM Programming User Programming User programming allows you to set when the air purifier is on and what blower speed to use. You may define up to 4 programs for the weekdays and up to 4 programs for the weekend. Before starting the programming process, first you should determine what times and blower speeds will best fit your needs. Use the charts below to organize and record the programs that you desire. Use a pencil so you can revise your records each time you change the programs. Table 4 WEEKDAYS WEEKENDS Program Setpoint Time Blower Speed Program Setpoint Time Blower Speed 1 1 2 2 3 3 4 4 NOTES: • Setpoint time is the time at which the blower speed will change. The specified blower speed will be active until the next setpoint time is reached. • The setpoint time can only be set in 10 minute increments. • Blower speed ranges from 0 to 3. Zero indicates that the blower is turned off, a setting of 1 is low, 2 is medium, and 3 represents a blower speed of high. • If you want the weekdays and the weekends to be identical, you should program both the weekday programs and the weekend programs with the same values. • If you use less than 4 programs, set the unused programs identical to one of the other programs. Table 5 below gives an example where programs 3 and 4 are identical. Table 5: Using 3 of the 4 Available Programs Program Setpoint Time Blower Speed 1 8:00 am 3 2 5:00 pm 2 3 9:30 pm 1 4 9:30 pm 1 41451-01 14 41451-01_Rev 8-6-04.pmd 14 8/5/04, 5:05 PM 15 41451-01 Programming To set or change the programs: 1. Press the PROGRAM key. Program 1 for weekdays will be shown with the hour position flashing to denote that you should set that value now. 2. Use the UP/DOWN keys to adjust the hour setting. Once set, press the PROGRAM key again. 3. Now, the minute position will be flashing. Use the UP/ DOWN keys to adjust the minute setting in 10 minute increments. Press PROGRAM to accept the value. 4. Finally, the blower speed will be flashing. Use the UP/ DOWN keys to adjust the blower speed setting from 0 to 3. Zero indicates that the blower is turned off, a setting of 1 is low, 2 is medium, and 3 represents a blower speed of high. Press PROGRAM to accept the blower speed setting. This completes the first program for weekdays. 5. The display will advance to the second program for weekdays with the hour position flashing. Follow steps 2 to 4 to set the second program. After setting each program, the display will advance to the next program number. After going through all four weekday programs, the unit will advance through each of the four weekend programs. The adjustment procedure (steps 2 to 4) is the same for each program. Fig. 23 Fig. 24 Fig. 25 PROGRAM PROGRAM PROGRAM PROGRAM NOTES: • For fast advance of the values, press and hold the UP/DOWN keys for 2 seconds. The values for program time or blower speed will advance quickly. • To exit programming mode and return to normal operating mode, either wait 15 seconds without any key presses or press DISPLAY to immediately return to normal operating mode. • Once entered, the programs are active and stored in the unit’s memory. You can unplug and move the air purifier and still retain the programs. 41451-01_Rev 8-6-04.pmd 15 8/5/04, 5:05 PM Programming Reviewing Programs You may want to review the programs to confirm that the settings are still acceptable. The following steps show you how to review the programs. To review programs: PROGRAM 1. With the air purifier On, press and hold the PROGRAM key. After 2 seconds, the display will advance through the 4 programs for weekdays and then the 4 programs for the weekend. You must hold the PROGRAM ...

Este manual também é adequado para os modelos :
Air - 30130 (1.06 mb)
Air - 30400 (1.06 mb)
Air - 30401 (1.06 mb)
Air - 30175 (1.06 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias