Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Precisionaire, Modelo Crank Lock HEPA Filter Housing C-4

Fabricante : Precisionaire
Arquivo Tamanho: 248.75 kb
Arquivo Nome : 61e6fb87-78d8-4737-88bb-6e3ee35092b9.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Gasket Seal Gasket Gel Seal Housing Knife Edge Sealing Flange A flange in the housing mates into a gel-filled channel on the filter. The gel seal guarantees filter-to-frame sealing and is recommended for critical applications. Flanders Filters - Foremost in Air Filtration Toll Free: 1-800-637-2803 Model Number Development C3G -1H1W -GGF -GLV -D1 Housing Material: Filter type: C3G - Gasket Seal GLV: Galvanized steel C4F -Fluid Seal 304: Type 304 S/S Housing Size: 304L: Type 304 L S/S Filters High x Wide 316: Type 316 S/S (See Chart) 316L: Type 316L S/S ALZ - 14 gauge aluminizedFilter Size: CCF - 12”x12”x11-1/2” HEPA Filter 2CCF -12”x12”x11-1/2” HEPA filter with a 2” prefilter 4CCF -12”x12”x11-1/2” HEPA filter with a 4” prefiler CGF - 12”x24”x11-1/2” HEPA Filter 2CGF-12”x24”x11-1/2” HEPA Filter with 2” prefilter 4CGF-12”x24”x11-1/2” HEPA filter with a 4” prefilter GCF-24”x12”x11-1/2” HEPA filter 2GCF-24”x12”x11-1/2” HEPA filter with 2” prefilter 4GCF-24”x12”x11-1/2” HEPA filter with 4” prefilter GGF-24”x24”x11-1/2” HEPA filter 2GGF-24”x24”x11-1/2” HEPA filter with 2” prefilter 4GGF-24”x24”x11-1/2” HEPA filter with 4” prefilter CC12-12”x12”x11-1/2” carbon adsorber CG12-12”x24”x11-1/2” carbon adsorber GC12-24”x12”x11-1/2” carbon adsorber GG12-24”x24”x11-1/2” carbon adsorber CG16-12”x24”x16” carbon adsorber GC16-24”x12”x16” carbon adsorber GG16-24”x24”x16” carbon adsorber GG18-24”x24”x18” carbon adsorber. (non-standard) Door Locations D1- Filter access and housing on one side only D1A - Doors on both sides, but filter access from one side only. D2 - Doors on both sides and filter access from both sides. The filter size arrangements listed at left are the only standard arrangements. 6” prefilters are available but non-standard. Any prefilter with a carbon housing is available but not standard. Multi-wide CC, CG and GC units are available but non-standard. CC16, CC18, CG18 & GC18 units are not available. Filter Usage and Housing Weight Height Filters/ Width Code Code Weight 1W 2W 3W 4W 5W 6W 7W 8W 1H Filters 1 2 3 4 5 6 7 8 Weight 105 190 270 380 460 540 2H Filters 2 4 6 8 10 12 14 16 Weight 200 305 460 610 765 920 3H Filters 3 6 9 12 15 18 21 24 Weight 255 405 590 810 995 1180 4H Filters 4 8 12 16 20 24 28 32 Weight 345 520 710 1040 1230 1420 (1) Filters/Weight: Top number indicates the number of filters required to fill the unit. Bottom number indicates the approximate weight in pounds of the housing EMPTY. Add 32 pounds for each HEPA/ULPA filter and 2 pounds per each prefilter to determine approximate weight when loaded with filters. Add 10% to calculate the approximate rigging weight of housings Flanders Filters - Foremost in Air Filtration Toll Free: 1-800-637-2803 Construction Details Notes: 1. Standard construction is 14 ga. galvanized steel housing and doors leak tight to +/- 3.0 in. w.g. 2. Maximum operating temperature for standard C-3 and C-4 Housings is 250°F. High temperature C-3 and C-4 Housings are available for 400°F continuous and 500 °F intermittent duty. Guide Specifications 1.0 HEPA/ULPA Filter Housings 1.1 Side access HEPA filter housings shall be C-3 and C-4 as manufactured by Flanders. 1.2 Units shall be factory-assembled housings with flanges for duct connections on the air entering and air leaving sides. 1.3 Housings shall be suitable for operation at +/-3.0 in. w.g. internal pressure. 2.0 Construction 2.1 Housings shall be made of galvanized or stainless steel with 11 ga. corner posts. Joints shall be inter- mittently welded and sealed with silicone. 2.2 Tracks for prefilters shall be fabricated from the same material as the housing. 2.3 The filter locking mechanism for the gel seal model shall be a 300 Series stainless steel hand-operated arm that moves the filter so its gel- filled channel mates with the internal housing knife edge sealing flange. The same mechanism shall also pull the filter away from the sealing flange when changing filters. 2.4 The filter locking mechanism for the gasket seal model housing shall be a 300 Series stainless steel and brass device. The mechanism shall press the gasketed filter against the housing’s sealing surface by means of a mechanical bolt and thrust assembly that is manually operated using a standard 3/4 inch socket or wrench. 3.0 Features 3.1 Model numbers and capacities shall be as speci- fied and/or shown on the drawings. 3.2 Provide options as specified. ® Flanders Filters, Inc. 531 Flanders Filter Road Washington, NC 27889 Phone: (252) 946-8081 Toll Free: (800) 637-2803 Fax: (252) 946-3425 Website: REPRESENTED BY: ...

Este manual também é adequado para os modelos :
Air - Crank Lock HEPA Filter Housing C-3 (248.75 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias