min. Installation Front cover Using the air purifier. ge.com Packaging must be removed from the True HEPA Filter before using your air purifier for the first time. Pull the bottom of the front cover toward you and lift up slightly to remove. Pull forward on the black Pre-Filter, using the pull tabs in the middle, and remove it from the unit. Pull tabs Gently pull forward on the 99.97% True HEPA Filter to remove it from the unit. Remove the plastic shipping cover from the filter and discard. Replace the 99.97% True HEPA Filter in the unit. There is a fixed gasket on the edges of the filter. That side goes toward the back of the unit. There is a tab on the front side of the 99.97% True HEPA Filter that says “FRONT.” If you are choosing to use the Charcoal Filter, install it in the back of the Pre-Filter now. Slide the Charcoal Filter under the tabs on the back side of the Pre-Filter. Install with the Charcoal Filter facing the 99.97% True HEPA Filter. Consumer SupportTroubleshooting Care and Cleaning 7 8 Using the air purifier. Insert the side tabs of the Pre-Filter into the slots of the unit; pull tabs should be to the outside. Push the Pre-Filter to snap into place. Insert the tabs at the top of the front cover into the holes at the front of the control panel. Push the bottom to the body to snap it into place. Operating Instructions Locate the air purifier for maximum effectiveness (see Location on page 6). Plug the power cord into a receptacle that meets the requirements on the rating plate. Push the POWER button and set for the desired circulation. FILTER RESET TIMER CIRCULAIRE SPEED Pre / HEPA 1-5/AUTO LIGHT SENSOR SPEED TIMER AIR 12345 1h2h4h8h AUTOCIRCULAIRENIGHT POOR GOOD Pre-Filter HEPA AUTOCIRCULAIRE Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions Care and cleaning of the air purifier. ge.com Turn off the air purifier and remove the plug from the wall outlet before cleaning. Front Cover and Body To clean: Use a soft cloth to clean the front cover and body. For stubborn dirt, use water with a very mild detergent. DO NOT use bleach or abrasives. Pre-Filter and Charcoal Filter Clean the Pre-Filter every 3 months. Cleaning may be needed more often, depending upon usage and the environment. To access: WARNING: Disconnect the power supply before servicing. Pull the bottom of the front cover toward you and lift up slightly to remove. Pull forward on the black Pre-Filter, using the pull tabs in the middle, and remove it from the unit. Pull tabs To clean: Remove the Charcoal Filter if installed. Use a clean cloth and water to remove dust accumulated on the Pre-Filter. The Charcoal Filter, if installed, needs to be changed every 3 months. The Charcoal Filter CANNOT be cleaned. It must be replaced. Charcoal Filters can be purchased in 4-packs at the retail store where you purchased your air purifier or by calling GE Parts and Accessories at 1.800.626.2002. The filter pack part number is RAPCF3. After drying the Pre-Filter thoroughly, replace the Charcoal Filter, if used. Replace the Pre-Filter and front cover. The Pre-Filter and front cover are not 9 dishwasher-safe. Consumer SupportTroubleshooting Care and Cleaning The 99.97% True HEPA Filter needs to be replaced every 12 months. The filter may need to be replaced more often, depending upon usage and the environment. 99.97% True HEPA Filters can be purchased at the retail store where you purchased your air purifier or by calling GE Parts and Accessories at 1.800.626.2002. The filter part number is RAPHF3. To access: Pull the bottom of the front cover toward you and lift up slightly to remove. Pull forward on the black Pre-Filter, using the pull tabs in the middle, and remove it from the unit. Pull the 99.97% True HEPA Filter forward (using the “FRONT” tag) to remove it from the unit. Place the new 99.97% True HEPA Filter into the unit. There is a fixed gasket on the edges of the filter. That side goes toward the back of the unit. There is a tab on the front side of the filter that says “FRONT.” Replace the Pre-Filter and front cover. These filters and cover are not dishwasher-safe. True HEPA Filter 10 Care and cleaning of the air purifier. Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions Pull tabs 11 Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support ge.com Air Intake and Outlet and Ventilation Grille Clean the Air Intake and Outlet around the Particle Sensor and the Ventilation Grille with a damp cloth. Be careful not to let dust fall back into the unit. Particle Sensor The Particle Sensor should be cleaned every 2 months. It is located on the right side of the unit. To clean: ¦ Open the cover. ¦ Use a wet cotton swab to clean the lens, dust intake and outlet. ¦ Wipe with a second cotton swab to dry. Failure to clean the sensor regularly will result in a malfunctioning of the particle sensor. The sensor will nee...
Este manual também é adequado para os modelos :Air - AFHC21AM (2.15 mb)