Facilidade de uso


, Do not use volatile fluids such as benzene, paint thinner, or scouring powder, as they may damage the surface° . Keep the unit dry. • Lightly vacuum the AIR QUALITY sensor every three months. AIR QUALITY SENSOR 1 Filter Replacement • There are two separate filters: True HEPA Filter and Carbon Pre-Filter_ • The CHECK FILTER indicator will signal when to replace the True HEPA Filter_The replacement period will vary depending on the hours of usage, air quality, and location of the unit. However, in most cases of normal use the filter will need to be replaced annually -Change the True HEPA Filter when the CHECK FILTER indicator is on. -For best performance, change the Carbon Pre-Fitter every three months. This filter should be disposed of when changed. Carbon Pre-Fitter Replacement 1. Turn off the air cleaner and unplug the electrical cord. 2. Remove the front panel by pulling gently from the lower portion of the panel. Do not force, the panel should remove easily. 3o Remove the Carbon Pre-Filter and plastic frame by gently pulling out from the bottom and down from the top° 4. Remove the Carbon Pre-Filter from the plastic frame and dispose of iL 5o Remove a replacement Carbon Pre- Filter from the resealable plastic bag and reseal to maintain the freshness of the remaining filter_ 6. Install the Carbon Pre_Fitter onto the plastic frame by pushing against six "hook and loop" squares on the back of the frame. (Diago 6A) 7o Install the plastic frame by inseding tabs up into the air cleaner and gently pushing in at the bottom tab until the frame fits into place snuggly. 8o Replace the front panel by hooking the panel on the top of the unit. Swing the panel in by pushing gently on each side of the unit and then lock it into place, 9o Plug in air cleaner and press POWER button until short "beep" sounds I AUTION: Do not wash and reuse the True HEPA Filter or the Carbon Pre-Filter as they will not work effectively, O O \ @ O 10 TrueHEPAFilterReplacement 1.Turnofftheair cleanerandunplugthe electrical cord. 2. Remove the front panel by pulling gently from the lower portion of the panel. Do not force, the panel should remove easily. 3_ Remove the Carbon Pre-Filter and plastic frame by gently pulling out from the bottom and down from the top. 4_ Remove the True HEPA Filter and dispose of it. 5. Remove the plastic wrap from the new True HEPA Filter and insert it with the arrow showing =air flow" pointing in toward the back of the air cleaner. The white tabs at the top and bottom of the True HEPA Filter will point out to the front of the unit. 6. Reinstall the plastic frame and Carbon Pre=Filter by inserting tabs up into the air cleaner and gently pushing in at the bottom tab until the frame fits into place snuggly, 7. Replace the front panel by hooking the panel on the top of the unit. Swing the panel in by pushing gently on each side of the unit and then lock it into place. 8. Plug in air cleaner and press POWER button until short "beep" sounds. 9. Press the RESET FILTER button by gently inserting a paperclip into the RESET FILTER hole on the control panel. The light will flash 5 times before a =beep" sounds to indicate the filter has been reset. See figure C on page 8 or Diag_ 9 to the right. The air cleaner will take 3-4 minutes to calibrate the AIR QUALITY sensor. During this time the sensor lights wilt flash on and off. Once the sensor has calibrated, the lights will stop flashing and the unit will begin in AUTO mode. O O @ @ @ @ O tl BATTERY REPLACEMENT 1_Squeeze tab of battery covert 2_At the same time pull cover out of remote° 3. insert battery as shown. 4. Close the battery cover_ O O CRADLE: The remote control has a separate walt.mountable storage cradle that can be conveniently attached to any wall using a screw, BATTERY USE oInsert 3V lithium battery CR2025 into the remote control ° Incorrect battery usage may cause battery fluid leakage andlor damage. ° When not using remote control for an ex- At tended period, remove the battery. ° Avoid dropping or damaging the remote control° Keep remote control away from direct sunlight or heaters. B_ PROPER OPERATING CONDITIONS • Operate the remote control facing the air cleaner. • Operate within 20 feel of the air cleaner. IMPROPER OPERATING CONDITIONS C_ ° Any location where there is inverter lighting equipment or electronic spontaneous lighting equipmenL • When objects or furniture are located between the remote and the air cleaner, • When air cleaner unit is located in direct sunlight, as sunlight may interfere with the infrared sensor. Dr ° in areas where fluorescent lighting is flickering due to worn-out bulbs. POWER: Use the power button to turn the power on and off° A short "beep" will sound when the unlt turns on or off. AUTO: When in AUTO mode, the air cleaner will automatically sense the amount of impurities in the air and adjust the fan speed accordingly. When the unit is first turned on it wilt default to AUTO mode. FAN SPEED o UP: Use this button to switch f...

Este manual também é adequado para os modelos :
Air - PLASMAWAVE 85150 (2.98 mb)
Air - PLASMAWAVE 85300 (2.98 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias