Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Blueair, Modelo INFINITY 2020

Fabricante : Blueair
Arquivo Tamanho: 1.39 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. ! WARNING Step 2 —Turn the Infinityt Air Purifier switch to the off position. Step 3 —Remove the Infinityt Air Purifier door. Step 4 —Unplug the power cord and flow sensor cable (if connected) from the enhancement module 9 ( See Fig. 7 and 8) Step 5 —Slide out the enhancement module assembly and safety screen. CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. ! WARNING Step 6 —Slide out the Safety Screen and set aside. NOTE: Best cleaning tools: 5 inch handle paint brush with 2 inch width (or greater) brush point (synthetic or natural bristle) (See Fig. 14) or vacuum cleaner with brush attachment. Step 7 —Gently stroke the ionization pins on the top plane of each bar with enough brush depth to hit front and back tips of the points in the ionization array. Use a gentle back and forth brushing motion to clean any small accumulations from the tips of the points. If desired, use vacuum cleaner with brush attachment to gently vacuum the frame and components of enhancement module. Step 8 —Reinstall the Safety Screen. Step 9 —Slide in enhancement module. Step 10 —Reconnect the power cord and flow sensor cable. Step 11 —Replace the Infinityt Air Purifier Door Step 12 —Turn the Infinityt Air Purifier switch to the on position. Step 13 —Turn heating and cooling system power on . 30° POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING. Tip of point with residue Tip of point after cleaning A06671 Fig. 14 --- Removal of Deposits from Ionization Pins GAPAB TROUBLESHOOTING CAUTION! SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage. The following instructions are for use by qualified personnel only. ! WARNING ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. The following procedures will expose electrical components. Disconnect power between checks and proceed carefully. The Infinityt Air Purifier is equipped with a power indicator light located on the door (see Fig. 13). This power indicator light will illuminate when the Infinityt Air Purifier door is installed, the power switch is in the on position, AND the fan coil blower is running and airflow is sensed. If the power indicator light is not illuminated, follow the troubleshooting steps below. Step 1 —Check that the Infinityt Air Purifier door is installed. NOTE: A magnet in the door (see Fig. 8) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is activated. Step 2 —Check that the Infinityt Air Purifier power switch is in the on (closed) position. Step 3 —Confirm that the fan coil blower is operating. Step 4 —Confirm that 208/230 VAC power is provided. Attach power supply connector to the air purifier when the fan coil blower is operating. NOTE: Even though power is supplied to the Infinityt Air Purifier, it will not turn on unless the airflow sensor senses airflow or the airflow sensor’s bypass plug is inserted. Step 5 —Confirm that the airflow sensor cable or airflow sensor bypass plug is connected to the power supply (See Fig. 7). Step 6 —If still not functioning, disconnect the airflow sensor cable and the power cord from the power supply. Remove the enhancement module from the air purifier cabinet and inspect the airflow sensor (See Fig. 11). Confirm the airflow sensor is properly seated in its bracket and the airflow sensor cable is connected to the back of the sensor. Replace the enhancement module. Step 7 —Reconnect the power cord to the power supply and insert the airflow sensor disable jumper (from parts bag). If the power indicator light illuminates, then replace the airflow sensor. Install the door onto the air purifier and turn the power switch to the “ON” position. Step 8 —If all of the above steps are completed and the power indicator light is still not illuminating, replace the power supply on the enhancement module. Note that there are no serviceable parts within the power supply. GAPAB 9 SPECIFICATIONS AND DIMENSIONS Table 1—Specifications and Dimensions GAPAB Specifications GAPABXCC1620 GAPABXCC2020 GAPABXCC2420 Color Taupe Metallic Taupe Metallic Taupe Metallic Cabinet Material 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel Electrical 208/230v/60Hz 208/230v/60Hz 208/230v/60Hz Maximum Airflow (CFM) 1350 180...

Este manual também é adequado para os modelos :
Air - INFINITY 1620 (1.39 mb)
Air - INFINITY 1620 (1.39 mb)
Air - INFINITY 2020 (1.39 mb)
Air - INFINITY 2420 (1.39 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias