Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Bionaire, Modelo BAP825

Fabricante : Bionaire
Arquivo Tamanho: 1.58 mb
Arquivo Nome : 1897e5ec-9b76-43e7-9cad-94218b46af5f.pdf
Língua de Ensino: en
Fotos e especificações  Bionaire  BAP825
Ir para baixar



Facilidade de uso


2. Pull air inlet grill towards you by grasping the finger tabs on both sides. 3. Remove HEPA filter by gripping on both sides and pulling forward. 4. Remove protective plastic bag from the filter cartridge. 5. This model utilizes a hang tab and filter clip. The clip can only be attached to the tabs on the filter one way only. The filter clip should easily slide onto the filter hang tab with only a small amount of pressure. DO NOT use force while attaching the clip to the filter (See Figure 1). Align the clip on the top of the HEPA filter with the rails on the inside of the air purifier unit. Gently slide the filter onto the rail (See Figure 2). NOTE: The side with the soft gasket should face inward. 6. Replace air inlet grill back onto unit securely. DO NOT POINT AIR OUTLET TOWARDS WALL. Figure 1 Figure 2 1. Set tower air purifier on a dry, level surface. 2. Plug cord into any standard 120V AC outlet. 3. To turn the air purifier on, press the power button ( ) and then select the desired operating speed by pressing any speed button on the remote control or on the control panel. 4. The speed is adjustable by pressing either the Speed Button on the remote control or on the control panel. 5. To turn the unit off, press the off button ( ) on either the remote control or on the control panel. 6. To start and stop oscillation of the air purifier, push the button identified as Oscillation ( ) on the remote control or control panel. CLEANING/MAINTENANCE INSTRUCTIONS Turn off and unplug the unit before cleaning. 1. The outside of the air purifier can be cleaned with a soft, damp cloth. 2. The rear air inlet grill can be removed and washed in warm soapy water (not dishwasher safe). Dry before replacing in the unit. 3. The front air outlet grill can be cleaned of dust with a small soft brush. WARNING: Do not allow moisture to come in contact with the main housing of the air purifier. FILTER REPLACEMENT INSTRUCTIONS 1. Filter Life Indicator – Your air purifier has an indicator light that illuminates when it is time to change the filter. 2. Every few weeks, check the condition of the filters. 3. Remove the air inlet grill. Remove and examine the foam pre-filter. If it has collected a noticeable amount of dust or lint, remove it from the inlet of the grill and wash it in warm soapy water. Rinse and drip dry the pre-filter thoroughly before replacing it into the inlet of the grill. 4.With the inlet grill removed, check the condition of the HEPA filters. If the filters are dirty, remove the used HEPA cartridge and properly dispose of it. DO NOT try to wash and re-use the HEPA filters. Replace with new HEPA filters, removing the protective polybag before inserting into the air purifier. NOTE: The side with the soft gasket should face inward. 5. The unit must be reset once the HEPA filters have been replaced. Reset the indicator by pressing the power button ( ) on the control panel for 2 seconds. 6. Filter Life – Under normal conditions of continuous use, the HEPA filters will operate efficiently for 3-6 months. Replacement filters are available from your local supplier or by calling 1-800-788-5350. 5 OPERATING INSTRUCTIONS 1. Plug into a 120V AC electrical outlet. 2. Press the power button ( ). The unit will turn onto high and the power light will illuminate letting you know the power is on. 3. You can then select the desired speed setting. This air purifier has three speed settings. You can select from HIGH ( ), MEDIUM ( ), or LOW ( ) by pushing the desired operating speed button on the control panel or the remote control. 4. To release negative ions into the filtered air, press the ionizer button ( ) to ON and the light will illuminate. 5. For optimum air filtration, it is recommended to operate the air purifier continuously. Its rugged motor has been designed to give many years of use. For continuous use, it’s recommended to operate the air purifier at the MEDIUM setting. For quieter operation or use in a bedroom, select the LOW setting. When high levels of air pollution are present, select the HI setting to quickly circulate and filter the room air. REMOTE CONTROL & OSCILLATION Your remote control requires (2) AAA batteries for operation. To install the batteries, simply depress and slide the back of the remote control with your thumb on the arrow indentation. Insert batteries according to the diagram shown inside and replace cover. • Do NOT mix old and new batteries. • DO NOT mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries. 4 D C E I F B G H J A Figure 3 A.INLET GRILL B.WASHABLE FOAM PRE-FILTER C.SPEED CONTROL D.POWER INDICATOR E. FILTERED AIR OUTLET F. FILTER INDICATOR LIGHT G.IONIZER CONTROL H.IONIZER LIGHT I. OSCILLATION BUTTON J. HEPA/CARBON FILTER Air Purifier Model # BAP825-U Filter Quantity Needed 2 Filter # BAPF30 Filter Description HEPA/Carbon TROUBLESHOOTING PROBLEM SOLUTION Unit will not operate • Check to make sure the unit is plugged in. • Check to make sure the unit is on b...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias