Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação AllerAir, Modelo 4000 Series

Fabricante : AllerAir
Arquivo Tamanho: 1.02 mb
Arquivo Nome : 37767590-f260-4fe0-b1bc-10fb94a74546.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


An additional 5-year warranty is provided on parts. This product is not covered against damage resulting from misuse. This warranty is provided to the original purchaser and may not be transferred. A return authorization number is required for warranty repairs. Please contact AllerAir at 1-888-852-8247 for more information. THEALLERAIRAIRFILTRATIONSYSTEM ACTIVATED CARBON Your AllerAir air purifier contains activated carbon that permanently traps dangerous airborne chemicals, gases and odors. This vital filter should be changed approximately every two to three years, depending on the environment in which the unit is operating. You can also upgrade your Exec, Vocarb or D unit at any time to accommodate a larger and deeper carbon filter suitable for removing heavier concentrations of chemicals, gases and odors. PRE-FILTER The pre-filter included with your unit removes larger particles and helps prolong the life of your HEPA filter. The pre-filer should be vacuumed or replaced every three months. LASER TESTED, MEDICAL-GRADE HEPA* HEPA or high-efficiency particulate air filters were originally developed by the military to remove radioactive dust, and are now the primary particle filtration systems used in hospitals, laboratories, electronic clean rooms and any application where clean air is critical. Today, HEPA filters are widely recommended by allergists, doctors and indoor air quality experts for home and office. They trap an amazing 99.97% of airborne particles at 0.3 microns, including dust, hair, pollen and even some bacteria and viruses. Depending on the particle level in the environment in which the unit is used, your HEPA filter should be replaced every three to five years. * Note that chemical and odor models D and DX feature a micro-particle filter which is rated to trap at least 95% airborne particles. THE ALLERAIR ADVANTAGE · Our units offer complete air filtration removing airborne chemicals, gases, odors and particles. · Our deep bed, activated carbon filters last longer than the average thin filter which is generally carbon sprayed onto a synthetic material. · Our units do not use dangerous ozone technology · Our units are manufactured to clean your air and therefore are not made with a plastic housing, or other materials which may off-gas chemicals. · Our units are powered by American-made motors that are energy efficient and cost only pennies a day to operate. IMPORTANTNOTICE PLANNING ON PAINTING YOUR HOME? READ THIS FIRST: Particles from paint may clog your HEPA filter, therefore we recommended that users unplug their units and remove the HEPA filter, storing it off-site until the paint job is complete. Due to the serious toxic nature of paint it is also recommended that your carbon filter be replaced or refilled in the weeks after the paint job is complete. See, Replacing HEPA and/or carbon filters, for instructions on how July/2007 Operation and Maintenance Manual 4000 - 5000 - 6000 Series Air Purifiers Congratulations! You're moments away from fresher, cleaner indoor air. Your new AllerAir unit will combat many of the chemicals, gases, odors and particles responsible for poor indoor air quality ( IAQ) . Poor IAQ may cause or worsen allergies, asthma, multiple chemical sensitivities ( MCS) and sick building syndrome. We recommend proper maintenance of your unit to keep it running efficiently for years to come. Operation: All units except D and DX models are shipped fully assembled and ready for use. ( D and DX model owners may refer to their additional instruction sheet for filter installation, or refer to Page 6 of this booklet. ) NOTE: As original packaging is required for warranty returns, new AllerAir owners are advised to keep boxes and shipping materials. Model # Serial # AllerAirIndustriesInc. Tollfree: 1-888-Fax: 1-877-allerair. comAllerAirIndustriesInc. Tollfree: 1-888-Fax: 1-877-allerair.com REPLACING HEPA AND/OR CARBON FILTERS 3 Step 10 Replace the base,making sure the arrow on the gold sticker lines up with unit's rear seam. Step 11 Replace the four screws. Step 12 Turn the unit back onto its wheels. It is now ready for use. Step 9 Put back the felt pad removed in STEP 4. STEP 1 Make sure the unit is set to STEP 2 STEP 3 "off" and the unit is unplugged. Place the unit upside down, so that the wheels face up. Using a #2 Philips screwdriver, remove the four screws that hold the base onto the unit. Grasp the wheels. Remove the base by pulling gently on the wheels STEP 4 Reach inside the unit, and remove felt pad. STEP 5 STEP 6 STEP 7 First, remove the carbon filter. (pull up gently by placing thumbs on the inner side of the filter) Then, remove the HEPA filter with the same technique. Now, place the new HEPA filter into the unit. STEP 8 Then, place the new carbon filter into the unit. See page 5 for instructions on replacing carbon filling. NEW HEPA NEW CARBON AllerAir Industries Inc.Toll free:1-888-852-8247 / Fax:1-877-688-2193 6 AllerAir Industries Inc.Toll free:1...

Este manual também é adequado para os modelos :
Air - 6000 Series (1.02 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias